石田 武和*; Vu, TheDang*; 宍戸 寛明*; 相澤 一也; 奥 隆之; 及川 健一; 原田 正英; 小嶋 健児*; 宮嶋 茂之*; 小山 富男*; et al.
Journal of Low Temperature Physics, 214(3-4), p.152 - 157, 2024/02
被引用回数:0 パーセンタイル:0.02(Physics, Applied)We built a new cryostat to apply a current-biased kinetic inductance detector (CB-KID) for conducting neutron transmission imaging of room temperature samples under pulsed neutrons. A Wood's metal alloy of melting temperature 75.2C was placed at room temperature to inspect the measurement system at J-PARC. Since one of the four phases of Wood's metal is a fine Cd-rich needle phase (width 25 m and length 5 mm), it is suitable for observing fine mosaic structure selectively by neutron imaging. The spatial resolution of the CB-KID imager was estimated as 10 m by using a Gd Siemens-star pattern. The CB-KID system is useful to conduct transmission imaging for various materials rather easily at room temperature.
宍戸 寛明*; Vu, TheDang*; 相澤 一也; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 奥 隆之; 曽山 和彦; 宮嶋 茂之*; et al.
Journal of Applied Crystallography, 56(4), p.1108 - 1113, 2023/08
被引用回数:0 パーセンタイル:0.02(Chemistry, Multidisciplinary)Recent progress in high-power pulsed neutron sources has stimulated the development of the Bragg dip and Bragg edge analysis methods using a two-dimensional neutron detector with high temporal resolution to resolve the neutron energy by the time-of-flight method. A delay-line current-biased kinetic inductance detector (CB-KID) is a two-dimensional superconducting sensor with a high temporal resolution and multi-hit capability. Here, it is demonstrated that a delay-line CB-KID with a B neutron conversion layer can be applied to high-spatial-resolution neutron transmission imaging and spectroscopy up to 100 eV. Dip structures are observed in the transmission spectra of YbSn single crystals, induced by Bragg diffraction and nuclear resonance absorption. The orientation mapping of YbSn crystals is successfully drawn based on the analysis of observed Bragg dip positions in the transmission spectra.
熊田 高之; 三浦 大輔*; 阿久津 和宏*; 大石 一城*; 森川 利明*; 河村 幸彦*; 鈴木 淳市*; 奥 隆之; 鳥飼 直也*; 新関 智丈*
Journal of Applied Crystallography, 55(5), p.1147 - 1153, 2022/10
被引用回数:1 パーセンタイル:29.53(Chemistry, Multidisciplinary)スピンコントラスト変調中性子反射率法は一つの試料一つのビームラインから複数の反射率曲線が得られる手法である。我々はその特徴を生かしてメチル化ポリシラザンから作られた多孔質シリカ界面においてアクリルウレタン樹脂は多孔質体内に入り込まないことを見出した。
宍戸 寛明*; 西村 和真*; Vu, TheDang*; 相澤 一也; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 奥 隆之; 曽山 和彦; et al.
IEEE Transactions on Applied Superconductivity, 31(9), p.2400505_1 - 2400505_5, 2021/12
被引用回数:0 パーセンタイル:0(Engineering, Electrical & Electronic)中性子イメージングは、重金属に対する高透過性、軽元素に対する高感度、同位体と中性子との特異な核反応による同位体選択性などの中性子ビームの特徴を活かした非破壊検査の有力な手段の一つである。本研究では、超伝導検出器である電流バイアス運動インダクタンス検出器(CB-KID)を用いて、パルス中性子源を用いた飛行時間法による波長分解中性子イメージングを行った。遅延時間型CB-KIDを用いて、GdAl単結晶を成長させたGd-Al合金試料の中性子透過像を取得した。その結果、単結晶はAl-Gd合金全体に渡って、形状,分布ともに良好に観察することができた。また、中性子の波長0.03nm以上でGdによる特徴的な中性子の吸収を確認した。さらに、15m 12mという限られた検出面で、同位体と中性子の核反応によって生じるGd共鳴ディップを観測することができた。また、Gdの共鳴ディップを用いてGd選択的イメージングを行ったところ、中性子の波長幅が1pmという限られた範囲で、明確なGd核の元素選択イメージング像を取得することに成功した。
Vu, TheDang; 宍戸 寛明*; 相澤 一也; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 奥 隆之; 曽山 和彦; 宮嶋 茂之*; et al.
Nuclear Instruments and Methods in Physics Research A, 1006, p.165411_1 - 165411_8, 2021/08
被引用回数:1 パーセンタイル:18.91(Instruments & Instrumentation)We found that the sizes of the Gd islands determined from the transmission image correlated strongly with those determined from the SEM image. We demonstrated the CB-KID could be used to identify (1) tiny voids in a thermally sprayed continuous GdO film in and (2) various mosaic morphologies and different eutectic microstructures in Wood's metal samples. The fact that the CB-KID system could be used to identify features of samples with a wide distribution of sizes and thicknesses is promising for real application of the device for imaging samples of interest to material scientists. Operating the CB-KID at higher temperatures appreciably improved the efficiency for simultaneously identifying the X and Y positions of hotspots. We also compared the detection efficiency with the PHITS simulations. We now plan to improve the detection efficiency by increasing the thickness of the B neutron conversion layer
奥平 琢也; 上田 祐生; 廣井 孝介; 元川 竜平; 稲村 泰弘; 高田 慎一; 奥 隆之; 鈴木 淳市*; 高橋 慎吾*; 遠藤 仁*; et al.
Journal of Applied Crystallography, 54(2), p.548 - 556, 2021/04
被引用回数:2 パーセンタイル:33.1(Chemistry, Multidisciplinary)Heスピンフィルタを中性子スピン解析子として使用することにより、パルス中性子源での中性子小角散乱実験において、偏極解析を行うことに成功した。本実験に使用したHeスピンフィルタは中性子小角散乱実験を行うために十分な立体角をカバーすることができ、He偏極緩和時間も数日と長く、これは実験を完遂するために十分な性能である。水素原子による非干渉性散乱は非常に大きく、試料の組成から計算によって非干渉性散乱量を見積もる試みが行われていたが、正確に非干渉性散乱量を決定することは難しかった。しかし本研究では試料内での中性子の多重散乱を考慮した偏極解析実験を行うことで、干渉性散乱と非干渉性散乱を正確に分離することが可能となった。現在までパルス中性子源での中性子小角散乱では、偏極解析の手法が確立されていなかったが、本成果によって、様々な種類の試料に対して干渉性散乱と非干渉性散乱を正確に分離することができるようになると予想される。
Vu, TheDang; 宍戸 寛明*; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 宮嶋 茂之*; 奥 隆之; 曽山 和彦; 相澤 一也; et al.
Superconductor Science and Technology, 34(1), p.015010_1 - 015010_10, 2021/01
被引用回数:3 パーセンタイル:27.71(Physics, Applied)We demonstrated that a four-readout superconducting neutron imaging system shows good spatial heterogeneity and linearity using the delay-line method. We examined the precise pattern of a B-dot-array absorber and found the X-direction pitch (Px) = 250.7 um with a scatter of (Hx)= 5.4 um and the Y-direction pitch (Py)= 249.1 um with a scatter of (Hy)= 3.4 um while the B dot array was fully extended toward the X direction across the detector sensitive area. We consider that this demonstrates detection with good spatial homogeneity and conclude. The transmission-imaging system is suitable for use at pulsed neutron facilities. We also reported a clear transmission image of tiny screws and nuts, and ladybug (insect). We recognize that further efforts to improve the detection efficiency are necessary to make using the detector more practical.
宍戸 寛明*; 西村 和真*; Vu, TheDang*; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 宮嶋 茂之*; 日高 睦夫*; 奥 隆之; et al.
Journal of Physics; Conference Series, 1590, p.012033_1 - 012033_8, 2020/10
被引用回数:0 パーセンタイル:0.01(Engineering, Electrical & Electronic)We demonstrate the development of an energy resolved neutron transmission imaging system via a solid-state superconducting detector, called current-biased kinetic-inductance detector (CB-KID). CB-KIDs comprise X and Y superconducting Nb meanderlines with Nb ground plane and a B conversion layer, which converts a neutron to two charged particles. CB-KID uses the delay-line method, and allows us to reconstruct the two-dimensional neutron transmission image of a test sample with four signal readout lines. We examined the capability of high spatial and energy (wavelength) resolved neutron transmission imaging over the sensor active area of 15 15 mm for various samples, including biological and metal ones. We also demonstrated the capability for the Bragg edge transmission and an energy-resolved neutron image in which stainless-steel specimens were discriminating from other specimens.
奥平 琢也; 奥 隆之; 猪野 隆*; 林田 洋寿*; 吉良 弘*; 酒井 健二; 廣井 孝介; 高橋 慎吾*; 相澤 一也; 遠藤 仁*; et al.
Nuclear Instruments and Methods in Physics Research A, 977, p.164301_1 - 164301_8, 2020/10
被引用回数:10 パーセンタイル:79.13(Instruments & Instrumentation)We are developing a neutron polarizer with polarized He gas, referred to as a He spin filter, based on the Spin Exchange Optical Pumping (SEOP) for polarized neutron scattering experiments at Materials and Life Science Experimental Facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC). A He gas-filling station was constructed at J-PARC, and several He cells with long spin relaxation times have been fabricated using the gas-filling station. A laboratory has been prepared in the MLF beam hall for polarizing He cells, and compact pumping systems with laser powers of 30 W and 110 W, which can be installed onto a neutron beamline, have been developed. A He polarization of 85% was achieved at a neutron beamline by using the pumping system with the 110 W laser. Recently, the first user experiment utilizing the He spin filter was conducted, and there have been several more since then. The development and utilization of He spin filters at MLF of J-PARC are reported.
飯澤 侑貴*; 宍戸 寛明*; 西村 和真*; Vu, TheDang*; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 宮嶋 茂之*; 日高 睦夫*; et al.
Superconductor Science and Technology, 32(12), p.125009_1 - 125009_8, 2019/12
被引用回数:13 パーセンタイル:59.07(Physics, Applied)Neutron imaging is one of the key technologies for non-destructive transmission testing. Recent progress in the development of intensive neutron sources allows us to perform energy-resolved neutron imaging with high spatial resolution. We have been developing a neutron imager aiming at conducting high spatial and temporal resolution imaging based on a delay-line neutron detector, called the current-biased kinetic-inductance detector, with a conversion layer B. The detector allowed us to obtain a neutron transmission image with four signal readout lines. Herein, we expanded the sensor active area, and improved the spatial resolution of the detector. We examined the capability of high spatial resolution neutron imaging over the sensor active area of 15 15 mm for various samples, including biological and metal ones. We also demonstrated an energy-resolved neutron image in which stainless-steel specimens were discriminating of other specimens with the aid of the Bragg edge transmission.
坂佐井 馨; 佐藤 節夫*; 瀬谷 智洋*; 中村 龍也; 藤 健太郎; 山岸 秀志*; 曽山 和彦; 山崎 大; 丸山 龍治; 奥 隆之; et al.
Quantum Beam Science (Internet), 1(2), p.10_1 - 10_35, 2017/09
J-PARC物質・生命科学実験施設では、中性子検出器、スーパーミラーやHeスピンフィルターなどの光学機器、及びチョッパー等の中性子デバイスが開発され、据え付けられている。また、計算環境として機器制御、データ取得、データ解析、及びデータベースの4つのコンポーネントが整備されている。また、物質・生命科学実験施設では実験に使用される様々な試料環境が利用可能である。本論文では、これらの現状について報告する。
奥 隆之; 中村 充孝; 酒井 健二; 勅使河原 誠; 達本 衡輝*; 米村 雅雄*; 鈴木 淳市*; 新井 正敏*
JAEA-Conf 2015-002, 660 Pages, 2016/02
第21回「先端的中性子源に関する国際協力」会議(ICANS-XXI)が2014年9月29日から10月3日に、茨城県立県民文化センター(水戸市)において開催された。この会議は日本原子力研究開発機構, 高エネルギー加速器研究機構, 総合科学研究機構により共催されたものである。会議では、大強度パルス中性子源を用いた新時代のサイエンスや応用研究の展開について、ワークショップ形式のセッションを主体として、ハードウェアからソフトウェア、そして放射線安全に至るまで、"インターフェイス"をキーワードに、さまざまな課題に関する活発な討論がなされた。本報文集はそれら72件の論文をまとめたものである。
酒井 健二; 奥 隆之; 林田 洋寿*; 吉良 弘*; 廣井 孝介; 猪野 隆*; 大山 研司*; 大河原 学*; 加倉井 和久; 篠原 武尚; et al.
JPS Conference Proceedings (Internet), 8, p.036015_1 - 036015_6, 2015/09
Heの中性子吸収断面積が強いスピン選択性を有することを利用した偏極Heフィルターは、ビーム調整が不要なため、ビームラインに設置すれば直ぐに使える簡便な中性子スピンフィルター(NSF)として利用できる。そのようなNSF実現のためには、NSFのHe偏極度を定常的にモニタするための核磁気共鳴(NMR)システムの開発が不可欠である。我々は断熱高速通過型(AFP)とパルス型NMRの特徴が相補的であることに着目して2つのシステムを併用した汎用性の高いNMRシステムを開発した。更に、J-PARCの中性子実験装置(BL10)での中性子透過率測定から得られたで校正しながら、温度、パルスNMRの振動磁場の大きさや印可時間などの測定条件を変えて、AFPとパルスNMRの信号間の相関を測定した。例えば、パルスNMR測定に起因する減偏極率を0.1%以下になるまでパルスNMRの検出感度を小さくしても、2つのNMR信号間の線形性は確認できた。これらの結果から、我々は開発したNMRシステムがHe偏極度モニタとして十分機能することを確認した。
酒井 健二; 奥 隆之; 林田 洋寿; 吉良 弘*; 篠原 武尚; 及川 健一; 原田 正英; 加倉井 和久; 相澤 一也; 新井 正敏; et al.
Journal of Physics; Conference Series, 528, p.012016_1 - 012016_7, 2014/07
被引用回数:2 パーセンタイル:69.29(Optics)中性子偏極実験において測定領域を熱外中性子まで広げることは興味深い。その実現には、He自身の核スピンを反転することで、冷から熱外まで幅広いエネルギー領域の中性子のスピン偏極と反転が可能な偏極Heスピンフリッパー(PHSF)が重要な役割を果たす。現在、J-PARC/MLFでは「可搬型PHSF」の開発を進めている。この装置は、Heガスを封入したガラスセルを、Heスピン偏極を保持するための直径20cm,長さ30cmの小型ソレノイド内に設置する。さらに、ガラスセルをレーザー照射することで、光ポンピング法(SEOP)によりHeを偏極した後に、ソレノイドごと中性子ビームラインに移動することで、可搬型PHSFとして利用する。われわれは、MLFの中性子ビームライン(BL10)で、PHSFの特性試験を行い、He核スピン反転前後の中性子透過率比の2次元分布測定から、本装置がPHSFとして十分機能することや、サンプルコイルの簡単な磁気イメージを測定できることを実証した。
長尾 誠也*; 新堀 雄一*; 田中 忠夫; 佐々木 隆之*; 斉藤 拓巳*; 桐島 陽*; 吉川 英樹; 飯島 和毅; 濱 克宏; 岩月 輝希; et al.
原子力バックエンド研究(CD-ROM), 20(1), p.3 - 14, 2013/06
本研究は、放射性廃棄物の地層処分における国内の地下水コロイドの影響評価研究の現状について各研究機関での研究を紹介し、実質的なネットワーク化と性能評価におけるコロイド影響の取り扱い方等について、今後の研究の方向性に関する提案を取りまとめた。具体的には、地下水コロイドの特性、地下環境における真性コロイドや擬似コロイドの移行挙動、国内における地下水コロイド研究の取り組み、コロイド評価の体系化、フィールド調査と実験室研究の連携、研究ネットワーク構築の必要性などについて解説するとともに、コロイド研究を展開するにあたって専門家が共有化しておくべき方向性を示した。
毛利 哲也; 丸山 修平; 羽様 平; 鈴木 隆之
Nuclear Technology, 179(2), p.286 - 307, 2012/08
被引用回数:11 パーセンタイル:63.41(Nuclear Science & Technology)臨界性、制御棒価値に引き続き、もんじゅ再起動炉心で実施された等温温度係数測定試験のデータ評価について述べる。最確値とその誤差を最も詳細なレベルで評価した。炉心間のデータ比較のために前回性能試験のデータも同レベルの詳細度で評価した。詳細評価の結果、再起動炉心の温度係数は前回試験に比べて約8%絶対値が低下することを確認した。感度解析により、その変化がおもにPuとAmの組成変化によるものであることを示した。解析精度を2種類の核データについて比較し、JENDL-4.0を使用した場合に前回試験の結果を実験誤差2%内で解析できることを確認した。一方、再起動炉心の結果に対しては、整合した結果が得られていないことが判明した。詳細に分析した結果、これまで想定していなかった外乱が影響している可能性を見いだした。
高野 和也; 福島 昌宏; 羽様 平; 鈴木 隆之
Nuclear Technology, 179(2), p.266 - 285, 2012/08
被引用回数:9 パーセンタイル:56.92(Nuclear Science & Technology)高速増殖原型炉もんじゅ再起動炉心において2010年5月に実施した制御棒価値測定について、最確値評価とその誤差を最も詳細なレベルで実施した。また、1994年9月に実施した制御棒価値測定に対しても、同レベルの詳細度にて再評価した。同炉心における制御棒間及び前回炉心と再起動炉心間における誤差の相関についても定量的に評価した。評価した最確値及び誤差に基づき、JENDL-3.3及びJENDL-4.0を用いて解析精度を確認した結果、径方向位置及びB装荷量によらず、いずれの制御棒に対しても2%以内の精度で解析できることがわかった。解析精度のさらなる改善のためには、遅発中性子割合の誤差を低減することが有効である。
北野 彰洋; 西 裕士; 鈴木 隆之; 岡嶋 成晃; 兼本 茂*
Proceedings of International Conference on Physics of Reactors; Advances in Reactor Physics; Linking Research, Industry, and Education (PHYSOR 2012) (CD-ROM), 14 Pages, 2012/04
従来、初号機の原子炉プラントにおいては、モックアップ試験結果に基づいた設計認可が必要とされている。炉心フィードバック特性が運転前に、実機にて確認ができれば、建設前に実施されるモックアップ試験を行う必要がなく、コスト・時間の大幅な削減が可能となる。本研究では、運転前に安全余裕を確認するため、シンセシス法という未臨界度測定法を提案する。シンセシス法とは、修正中性子源増倍法(MSM法)とMSM法の基準未臨界度を炉雑音法にて測定する組合せによる未臨界度測定である。制御棒価値と温度フィードバック反応度について、100MWe, 300MWe, 750MWe, 1500MWe規模の高速炉を対象に、シンセシス法の適用性を確認するための数値実験を行った。また、MSM法及び炉雑音法について、中性子検出器の数,位置についてもサーベイ計算を実施した。結果から中性子検出器は炉心中央の上部と、径方向ブランケット領域上部に3つ以上の検出器を利用することで、-0.5から-2までの未臨界度の場合は、10%、さらに深い未臨界度の場合は15%で測定が可能である見通しを得た。
酒井 健二; 奥 隆之; 篠原 武尚; 吉良 弘; 大井 元貴; 前川 藤夫; 加倉井 和久; 猪野 隆*; 有本 靖*; 清水 裕彦*; et al.
Journal of Physics; Conference Series, 340, p.012037_1 - 012037_7, 2012/02
被引用回数:2 パーセンタイル:62.54(Physics, Condensed Matter)J-PARC物質生命科学実験施設(MLF)では、Xeの共鳴ピークを用いた中性子-原子核スピン相関項に起因する中性子偏極能力を検知する実験が計画されている。スピン交換光ポンピング(SEOP)法により低磁場,室温で高偏極可能なXeガスは、中性子光学定理(NOPT)検証に適した標的核になることが期待できる。われわれはNOPTに基づいて、実験の測定量を評価し、偏極Xeガス生成装置を開発し、装置特性のビーム試験を進めてきた。本論文は、実験の現状について報告する。
千葉 豪*; 羽様 平; 金城 秀人*; 西 裕士; 鈴木 隆之
JAEA-Research 2011-034, 42 Pages, 2011/12
「もんじゅ」炉心体系を対象として、ドップラー係数の不確かさを最新の知見を取り込んで定量的に評価した。(1)核データ,計算手法に起因する不確かさ、(2)核分裂生成物の核データに起因する不確かさ、(3)制御棒位置に起因する不確かさ、(4)温度依存性を近似的に取り扱う不確かさ、(5)燃料平均温度に起因する不確かさ、(6)温度の空間分布の取り扱いに由来する不確かさ、などを評価し、ドップラー係数の不確かさ(2相当)として11.7%を得た。