Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Aso, Tomokazu; Teshigawara, Makoto; Hasegawa, Shoichi; Muto, Hideki; Aoyagi, Katsuhiro; Nomura, Kazutaka; Takada, Hiroshi
Journal of Physics; Conference Series, 1021(1), p.012085_1 - 012085_4, 2018/06
Times Cited Count:0 Percentile:0.11(Nuclear Science & Technology)Aso, Tomokazu; Teshigawara, Makoto; Hasegawa, Shoichi; Aoyagi, Katsuhiro*; Muto, Hideki*; Nomura, Kazutaka*; Takada, Hiroshi; Ikeda, Yujiro
JAEA-Technology 2017-021, 75 Pages, 2017/08
Liquid hydrogen is employed as a cold neutron moderator material at the spallation neutron source of Materials and Life science experimental Facility of Japan Proton Accelerator Research Complex (J-PARC). From January 2015, it became observable that the differential pressure between heat exchangers and an 80 K adsorber (ADS) in a helium refrigerator system increased with operating time. In November 2015, the differential pressure rise became more significant, leading to degrade the refrigerating performance in cooling liquid hydrogen. In order to investigate the cause of the abnormal differential pressure rise between the heat exchangers and the ADS, we carried out visual inspection inside the heat exchangers and analyzed the impurities contained in the helium gas. Unfortunately, we could not identify the impurities causing the performance degradation, but observed a trace of oil in the inlet piping of the heat exchanger. Based on investigations of the abnormal events occurred in the refrigerators with similar refrigerating capacity at other facilities, we took measures that cleaning the heat exchangers with Freon and replacing the ADS with new one. As a result, the differential pressure rise phenomenon was removed to recover the performance. We have detected oil from the Freon used for cleaning the heat exchangers and at a felt supporting charcoal packed in the ADS. In particular, oil was accumulated in membranous form onto the felt at the entrance side in the ADS. The amount of oil contained in the helium gas was about 10 ppb or so, less than the design value, in the helium refrigerator. However, the oil accumulated onto the felt in the ADS through long operating period may cause abnormal differential pressure rise, leading to the performance degradation of the helium refrigerator. Further study is needed to specify the cause more clearly.
Tatsumoto, Hideki; Aso, Tomokazu; Otsu, Kiichi; Kawakami, Yoshihiko; Aoyagi, Katsuhiro; Muto, Hideki
IOP Conference Series; Materials Science and Engineering, 101, p.012107_1 - 012107_8, 2015/12
Times Cited Count:0 Percentile:0.05(Thermodynamics)The Japan Proton Accelerator Research Complex (J-PARC) cryogenic hydrogen system was completed in April 2008. The proton beam power was gradually increased to 500 kW. A trial 600-kW proton beam operation was successfully completed in April 2015. We achieved long-lasting operation for more than three months. However, thus far, we encountered several problems such as unstable operation of the helium refrigerator because of some impurities, failure of a welded bellows of an accumulator, and hydrogen pump issues. Furthermore, the Great East Japan Earthquake was experienced during the cryogenic hydrogen system operation in March 2011. In this study, we describe the operation characteristics and our experiences with the J-PARC cryogenic hydrogen system.
Awaji, Satoshi*; Namba, Masashi*; Watanabe, Kazuo*; Ito, Shun*; Aoyagi, Eiji*; Kai, Hideki*; Mukaida, Masashi*; Okayasu, Satoru
IEEE Transactions on Applied Superconductivity, 21(3), p.3192 - 3195, 2011/06
Times Cited Count:5 Percentile:33.61(Engineering, Electrical & Electronic)The flux pinning behaviors for the heavy ion irradiated Er123 films are investigated based on the detailed (, , ) properties. The double peaks of curves for //c appear in case of the matching field of 0.3 T along -axis and 1.7 T tilted from -axis. In addition, the peaks on () at = 0 (B//c), which originate from the columnar defects, decrease with increasing magnetic field but increase again near the irreversibility field. We found that the cooperation model of the -axis correlated and random pinning centers can describe the observed double peak behavior of (B) and the angular dependence of related to the correlated pinning.
Tanaka, Hitoshi*; Takao, Masaru*; Matsushita, Tomohiro*; Aoyagi, Hideki*; Takeuchi, Masao*; Agui, Akane; Yoshigoe, Akitaka; Nakatani, Takeshi
Hoshako, 19(1), p.27 - 32, 2006/01
no abstracts in English
Nakatani, Takeshi; Agui, Akane; Yoshigoe, Akitaka; Tanaka, Hitoshi*; Takao, Masaru*; Takeuchi, Masao*; Matsushita, Tomohiro*; Aoyagi, Hideki*
JAERI-Tech 2005-027, 29 Pages, 2005/05
We measured the orbit fluctuation caused by APPLE-2 type undulator (ID23) installed in the SPring-8 storage ring by using the developed real time measurement system of electron and photon beam position monitors. We quantitatively found two characteristic fluctuations correlating with the ID23 motion by wavelet transform which is a kind of frequency analysis. One originates from the variation of error field during the ID drive. The other originates from the stray magnetic field leaked from the servomotors for the phase drive. Using these results, we tried to get rid of the effect of error fields on the beam orbit by the precise feed-forward correction table and the stray field shield. Consequently we succeeded in suppressing the orbit fluctuation down to sub-micron during the gap drive, which is observed by photon beam position monitors installed in downstream 20m from each light source point.
Nakatani, Takeshi; Agui, Akane; Yoshigoe, Akitaka; Matsushita, Tomohiro*; Takao, Masaru*; Takeuchi, Masao*; Aoyagi, Hideki*; Tanaka, Hitoshi*
JAERI-Tech 2004-013, 16 Pages, 2004/12
We observed two characteristic electron orbit fluctuations caused when the phase of ID23 (APPLE-2 type undulator) installed at SPring-8 was driven. One was caused by the variation of magnetic error filed of ID23 when the phase was driven. The other was caused by the noise from the phase drive system which adoped AC servomotors. We measured these orbit fluctuations synchronized with the phase motion using the real-time electron beam position measurement system. The part of the orbit fluctuation was supressed by the correction table which was made referring to the obtained data.
Matsushita, Tomohiro*; Agui, Akane; Yoshigoe, Akitaka; Takao, Masaru*; Aoyagi, Hideki*; Takeuchi, Masao*; Nakatani, Takeshi; Tanaka, Hitoshi*
AIP Conference Proceedings 705, p.21 - 24, 2004/00
no abstracts in English
Nakatani, Takeshi; Agui, Akane; Yoshigoe, Akitaka; Matsushita, Tomohiro*; Takao, Masaru*; Aoyagi, Hideki*; Takeuchi, Masao*; Tanaka, Hitoshi*
AIP Conference Proceedings 705, p.290 - 293, 2004/00
We have developed a new method to extract only the orbit fluctuation caused by changing magnetic field error of an insertion device (ID). This method consists of two main parts. (i) The orbit fluctuation is measured with modulating the error field of the ID by using the real-time beam position measuring system. (ii) The orbit fluctuation depending on the variation of the error field of the ID is extracted by the filter applying the Wavelet Transform. We call this approach the amplitude modulation method. This analysis technique was applied to measure the orbit fluctuation caused by the error field of APPLE-2 type undulator (ID23) installed in the SPring-8 storage ring. We quantitatively measured two kinds of the orbit fluctuation which are the static term caused by the magnetic field error and the dynamic term caused by the eddy current on the ID23 chamber.
Agui, Akane; Aoyagi, Hideki*; Yoshigoe, Akitaka; Nakatani, Takeshi
JAERI-Tech 2003-089, 23 Pages, 2003/12
no abstracts in English
Nakatani, Takeshi; Tanaka, Hitoshi*; Takao, Masaru*; Agui, Akane; Yoshigoe, Akitaka; Takeuchi, Masao*; Aoyagi, Hideki*; Okuma, Haruo*
JAERI-Tech 2003-048, 29 Pages, 2003/05
no abstracts in English
Matsushita, Tomohiro*; Agui, Akane; Yoshigoe, Akitaka; Nakatani, Takeshi; Tanaka, Hitoshi*; Takao, Masaru*; Aoyagi, Hideki*; Takeuchi, Masao*
Hoshako, 15(5), p.303 - 307, 2002/05
no abstracts in English
Agui, Akane; Yoshigoe, Akitaka; Nakatani, Takeshi; Matsushita, Tomohiro*; Saito, Yuji; Mizumaki, Masaichiro*; Yokoya, Akinari; Tanaka, Hitoshi*; Miyahara, Yoshikazu*; Shimada, Taihei; et al.
Hoshako, 14(5), p.339 - 348, 2001/11
no abstracts in English
Agui, Akane; Yoshigoe, Akitaka; Nakatani, Takeshi*; Matsushita, Tomohiro*; Saito, Yuji; Yokoya, Akinari; Tanaka, Hitoshi*; Miyahara, Yoshikazu*; Shimada, Taihei; Takeuchi, Masao*; et al.
Review of Scientific Instruments, 72(8), p.3191 - 3197, 2001/08
Times Cited Count:21 Percentile:71.54(Instruments & Instrumentation)no abstracts in English
Aso, Tomokazu; Teshigawara, Makoto; Hasegawa, Shoichi; Muto, Hideki*; Aoyagi, Katsuhiro*; Takada, Hiroshi; Ikeda, Yujiro
no journal, ,
no abstracts in English
Teshigawara, Makoto; Aso, Tomokazu; Hasegawa, Shoichi; Muto, Hideki*; Aoyagi, Katsuhiro*; Takada, Hiroshi; Ikeda, Yujiro
no journal, ,
Performance degradation of helium refrigerator was occurred for liquid hydrogen circulation system of J-PARC high intensity neutron source since 2015. In order to find the cause of performance degradation of helium refrigerator, we investigated the impurities in helium gas and accumulated oil in inside cold box components by quadrupole mass spectrometer and organic solvent extraction. The measured impurities and accumulated oil were less than design value. We collected 143g of total amount of accumulated oil from heat exchanger and adosorber, which was corresponded to estimated value from 10 ppb of oil contamination in helium and accumulated operation period. However, we only could find out that accumulated oil like coating film on top surface of felt, which was used to hold the active charcoal in adsorber. We report detailed measurement results of impurities, accumulated oil, etc., to find the cause of performance degradation.
Teshigawara, Makoto; Aso, Tomokazu; Muto, Hideki*; Aoyagi, Katsuhiro*; Takada, Hiroshi; Ikeda, Yujiro
no journal, ,
Performance degradation of helium refrigerator was occurred for liquid hydrogen circulation system of J-PARC high intensity neutron source since 2015. During cause investigation of performance degradation of helium refrigerator, we found out that accumulated oil like coating film on top surface of felt, which was used to hold the active charcoal in adsorber, might cause pressure difference in adsorber. We performed cold nitrogen gas flow test in the felt accumulated oil and found out that frozen oil under cold nitrogen flow caused the pressure difference.
Aso, Tomokazu; Teshigawara, Makoto; Hasegawa, Shoichi; Muto, Hideki; Aoyagi, Katsuhiro; Nomura, Kazutaka; Takada, Hiroshi
no journal, ,
no abstracts in English
Aso, Tomokazu; Teshigawara, Makoto; Hasegawa, Shoichi; Muto, Hideki*; Aoyagi, Katsuhiro*; Takada, Hiroshi; Ikeda, Yujiro
no journal, ,
no abstracts in English
Aso, Tomokazu; Teshigawara, Makoto; Hasegawa, Shoichi; Muto, Hideki*; Aoyagi, Katsuhiro*; Takada, Hiroshi
no journal, ,