Hiroki, Seiji; Hayashi, Naoki; Kawase, Masato; Noda, Fumiaki; Saha, P. K.; Sako, Hiroyuki; Takahashi, Hiroki; Ueno, Akira; Arakida, Yoshio*; Lee, S.*; et al.
Proceedings of 11th European Particle Accelerator Conference (EPAC '08) (CD-ROM), p.1131 - 1133, 2008/06
A set of six multi-wire profile monitors (MWPMs) has been installed in the injection area of the RCS (Rapid-Cycling Synchrotron), and contributed to the initial commissioning for establishing an optimum injection orbit. The Au coated W wires (0.1 mm dia.) for the H beam are fixed to a ceramic wind frame for two directions (horizontal and vertical with 17.7 deg. tilt, typically 51 wires with 2.9 mm or 9.5 mm distance), and the frame can be scanned for horizontal or vertical direction by using a stepping-motor driven actuator. A combination of the 17.7 deg. tilt wires and the precise scan function provides two step measurements, i.e. a rough profile is obtained only at one shot, and a detailed profile is measured for typically 101 shots (10 mm scan at 0.1 mm interval) thereafter. The beam induced charge signals are amplified, integrated and held by using a signal processing circuit. The signals are sequentially retrieved through multiplexers and digitized for obtaining a beam profile.
Kuramochi, Masaya*; Kinsho, Michikazu; Irie, Yoshiro*; Sugai, Isao*; Igarashi, Susumu*; Arakida, Yoshio*; Takeda, Yasuhiro*
Dai-14-Kai Kasokuki Kagaku Kenkyu Happyokai Hokokushu, p.637 - 639, 2003/00
Three charge-exchange foils are used in J-PARC 3GeV Synchrotron(RCS). One is used for changing H to H by stripping electrons, and the others are used for changing H and H to H which are failed to strip at the first foil. In this paper, we will describe the temperature distribution at the charge-exchange foils calculated by a simulation code 'ANSYS' where the particle distribution is based on a particle tracking code 'ACCSIM'.