Refine your search:     
Report No.
 - 
Search Results: Records 1-11 displayed on this page of 11
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

New excited 2$$^+$$ and 3$$^-$$ two-proton states in $$_{84}^{210}$$Po$$_{126}$$ populated by two-proton transfer

Dupont, E.*; Astier, A.*; Petrache, C. M.*; Lv, B. F.*; Deloncle, I.*; Kiener, J.*; Orlandi, R.; Makii, Hiroyuki; Nishio, Katsuhisa; Hirose, Kentaro; et al.

Physical Review C, 101(1), p.014309_1 - 014309_6, 2020/01

 Times Cited Count:1 Percentile:14.01(Physics, Nuclear)

Journal Articles

Effects of the nuclear structure of fission fragments on the high-energy prompt fission $$gamma$$-ray spectrum in $$^{235}$$U($$n_{rm th},f$$)

Makii, Hiroyuki; Nishio, Katsuhisa; Hirose, Kentaro; Orlandi, R.; L$'e$guillon, R.; Ogawa, Tatsuhiko; Soldner, T.*; K$"o$ster, U.*; Pollitt, A.*; Hambsch, F.-J.*; et al.

Physical Review C, 100(4), p.044610_1 - 044610_7, 2019/10

 Times Cited Count:11 Percentile:75.05(Physics, Nuclear)

Journal Articles

A New detector system for the measurement of high-energy prompt $$gamma$$-rays for low-energy neutron induced fission

Makii, Hiroyuki; Nishio, Katsuhisa; Hirose, Kentaro; Orlandi, R.; L$'e$guillon, R.*; Ogawa, Tatsuhiko; Soldner, T.*; Hambsch, F.-J.*; A$"i$che, M.*; Astier, A.*; et al.

Nuclear Instruments and Methods in Physics Research A, 906, p.88 - 96, 2018/10

 Times Cited Count:3 Percentile:30.45(Instruments & Instrumentation)

We have developed a new setup to measure prompt fission $$gamma$$-ray spectra in neutron induced fission up to energies sufficient to reveal the structure associated with giant dipole resonances of fission fragments. The setup consists of multi-wire proportional counters, to detect both fission fragments in coincidence, and two large volume (101.6 mm in diameter and 127.0 mm in length) LaBr$$_{3}$$(Ce) scintillators, to measure the $$gamma$$-rays. The setup was used to obtain the prompt fission $$gamma$$-ray spectrum for thermal neutron induced fission of $$^{235}$$U at the PF1B cold-neutron beam facility of the Institut Laue-Langevin, Grenoble, France. We have successfully measured the $$gamma$$-ray spectrum up to energies of about 20 MeV, what extends the currently known $$gamma$$-ray spectrum limit to higher energies by approximately a factor of two.

Journal Articles

EXILL; A High-efficiency, high-resolution setup for $$gamma$$-spectroscopy at an intense cold neutron beam facility

Jentschel, M.*; Blanc, A.*; de France, G.*; K$"o$ster, U.*; Leoni, S.*; Mutti, P.*; Simpson, G.*; Soldner, T.*; Ur, C.*; Urban, W.*; et al.

Journal of Instrumentation (Internet), 12(11), p.P11003_1 - P11003_33, 2017/11

 Times Cited Count:34 Percentile:84.59(Instruments & Instrumentation)

Journal Articles

Measurement of high-energy prompt $$gamma$$-rays from neutron induced fission of U-235

Makii, Hiroyuki; Nishio, Katsuhisa; Hirose, Kentaro; Orlandi, R.; L$'e$guillon, R.; Ogawa, Tatsuhiko; Soldner, T.*; Hambsch, F.-J.*; Astier, A.*; Pollitt, A.*; et al.

EPJ Web of Conferences, 146, p.04036_1 - 04036_4, 2017/09

 Times Cited Count:4 Percentile:90.94

The measurement of the prompt fission $$gamma$$-ray spectrum (PFGS) is quite important to study the de-excitation process of neutron-rich fission fragments as well as to generate data required to design a generation-IV reactors. The PFGS measured for spontaneous fission of $$^{252}$$Cf shows a broad hump at energies more than 8 MeV. This is interpreted as a giant dipole resonance (GDR) of the fragments centered around 15 MeV. To understand how the GDR is populated in the fission process, one needs to measure the PFGS for the reactions with the mass yields different from the spontaneous fission of $$^{252}$$Cf, such as (n,f). The measurements of the PFGS for (n,f), however, are limited less than 9 MeV even in the recent experiment. This prompts us to make a new measurement to extend the know PFGS up to 20 MeV. The measurement has been carried out at the PF1B beam line of Institut Laue-Langevin. In this contribution we will present the results obtained the measurement.

Journal Articles

$$B(E2;2^+_1rightarrow 0^+_1)$$ value in $$^{90}$$Kr

R$'e$gis, J.-M.*; Jolie, J.*; Saed-Samii, N.*; Warr, N.*; Pfeiffer, M.*; Blanc, A.*; Jentschel, M.*; K$"o$ster, U.*; Mutti, P.*; Soldner, T.*; et al.

Physical Review C, 90(6), p.067301_1 - 067301_4, 2014/12

 Times Cited Count:23 Percentile:80.47(Physics, Nuclear)

Oral presentation

Measurement of high-energy prompt fission $$gamma$$-rays from neutron induced fission of $$^{235}$$U

Makii, Hiroyuki; Nishio, Katsuhisa; Hirose, Kentaro; Orlandi, R.; L$'e$guillon, R.; Ogawa, Tatsuhiko; Soldner, T.*; Hambsch, F.-J.*; A$"i$che, M.*; Astier, A.*; et al.

no journal, , 

The Japanese government has a plan to remove the fuel debirs for the full deconstruction of Fukushima I Nuclear Power Plants. The fuel debris must be removed without reaching criticality. However, it is difficult to monitor the fission rate due to the background $$gamma$$ rays coming from long-lived fission products. We are proposing to develop a system based on the use of the high-energy prompt fission $$gamma$$ rays, whose energies are high enough to be separated from the background. To design the system, it is essential to know the spectrum of prompt fission $$gamma$$ rays up to more than 7 MeV for $$^{235}$$U($$n, f$$). So far, no data are available in the $$gamma$$-ray energy range larger than 7 MeV. This prompted us to make a new measurement to extend the $$gamma$$-ray spectrum limit to higher energies. The measurement has been carried out at the PF1b cold-neutron beam facility of the Institut Laue-Langevin. In this contribution we will present the results obtained the measurement.

Oral presentation

Measurement of high-energy prompt fission $$gamma$$ rays in $$^{235}$$U(n$$_{th}$$,f)

Ogawa, Tatsuhiko; Makii, Hiroyuki; Nishio, Katsuhisa; Hirose, Kentaro; Orlandi, R.; L$'e$guillon, R.*; Soldner, T.*; Hambsch, F.-J.*; A$"i$che, M.*; Astier, A.*; et al.

no journal, , 

Measurement of $$gamma$$-rays emitted from fission of actinide has been conducted for radiation transport analysis in reactors, safety of spent fuel, and fundamental nuclear physics. In earlier studies, $$gamma$$-rays up to 8 MeV were measured because they are those emitted by fission fragments at excited states. According to some theoretical studies, however, some fission fragments have excitation energy up to 20 MeV and they emit $$gamma$$-rays above 8 MeV. In this study, the $$gamma$$-rays produced by fission of $$^{235}$$U induced by thermal neutrons were measured with LaBr scintillators at the high-flux reactor in the Institut Laue Langevin. The obtained $$gamma$$-ray spectrum agreed with the earlier measurement below 8 MeV, forms a bump above 10 MeV, and smoothly continued up to 20 MeV. The measurement in this study clarified the $$gamma$$-ray energy spectrum attributed to fission reactions up to 20 MeV in case of $$^{235}$$U(n$$_{th}$$,f).

Oral presentation

Measurement of high-energy prompt fission $$gamma$$ rays in $$^{235}$$U(n$$_{th}$$,f)

Ogawa, Tatsuhiko; Makii, Hiroyuki; Nishio, Katsuhisa; Hirose, Kentaro; Orlandi, R.; L$'e$guillon, R.*; Soldner, T.*; Hambsch, F.-J.*; A$"i$che, M.*; Astier, A.*; et al.

no journal, , 

Measurement of $$gamma$$-rays emitted from fission of actinide has been conducted for radiation transport analysis in reactors, safety of spent fuel, and fundamental nuclear physics. In earlier studies, $$gamma$$-rays up to 8 MeV were measured because they are those emitted by fission fragments at excited states. According to some theoretical studies, however, some fission fragments have excitation energy up to 20 MeV and they emit $$gamma$$-rays above 8 MeV. In this study, the $$gamma$$-rays produced by fission of $$^{235}$$U induced by thermal neutrons were measured with LaBr scintillators at the high-flux reactor in the Institut Laue Langevin. The obtained $$gamma$$-ray spectrum agreed with the earlier measurement below 8 MeV, forms a bump above 10 MeV, and smoothly continued up to 20 MeV. The measurement in this study clarified the $$gamma$$-ray energy spectrum attributed to fission reactions up to 20 MeV in case of $$^{235}$$U(n$$_{th}$$,f).

Oral presentation

Measurement of high-energy prompt fission $$gamma$$-ray emission in $$^{235}$$U ($$n_{rm th},f$$)

Makii, Hiroyuki; Nishio, Katsuhisa; Hirose, Kentaro; Orlandi, R.; L$'e$guillon, R.*; Ogawa, Tatsuhiko; Soldner, T.*; K$"o$ster, U.*; Hambsch, F.-J.*; Kawano, Toshihiko*; et al.

no journal, , 

Oral presentation

Measurement of high-energy prompt fission gamma-rays for $$^{235}$$U(n$$_{rm th}$$,f)

Nishio, Katsuhisa; Makii, Hiroyuki; Hirose, Kentaro; Orlandi, R.; L$'e$guillon, R.*; Ogawa, Tatsuhiko; Soldner, T.*; K$"o$ster, U.*; Pollitt, A.*; Hambsch, F.-J.*; et al.

no journal, , 

no abstracts in English

11 (Records 1-11 displayed on this page)
  • 1