Dechenaux, B.*; Brovchenko, M.*; 荒木 祥平; 郡司 智; 須山 賢也
Annals of Nuclear Energy, 223, p.111555_1 - 111555_11, 2025/12
被引用回数:0 パーセンタイル:0.00(Nuclear Science & Technology)The safe retrieval of the fuel debris generated during the Fukushima Daiichi nuclear accident poses a number of challenges, among which an important one is to ensure the criticality safety of the recovery operations. At the heart of the problem lies the intrinsically heterogeneous nature of the problem, and the appearance of complex and disordered media whose neutronic properties are difficult to accurately characterize and reproduce in neutron transport simulations. Typically, a similar, simpler, problem is encountered in the modeling of assemblies with missing fuel rods. In both problems, the availability of experimental facilities capable of validating both the nuclear data and the simulation schemes in heterogeneous configurations is crucial. The modified STACY installation has been specially designed to provide and carry out critical experiments, allowing for highly non-uniform configurations, that will directly support fuel debris recovery operations, but can also be used for other experimental programs. The present work describes a method to consistently and orderly sample non-uniform core configurations in the modified STACY facility, and proposes two critical heterogeneous core configurations. They have the advantage to present a high sensitivity to the water thermal scattering law, whose importance was found to be more significant for more heterogeneous configurations. The proposed experiments will contribute to the exploration and validation of heterogeneous critical systems.
郡司 智; 荒木 祥平; Dechenaux, B.*; Brovchenko, M.*; 會澤 栄寿; 関 真和; 新垣 優; 吉川 智輝; 井澤 一彦
no journal, ,
燃料デブリの臨界特性は、含まれる燃料及び水分の量により大きく変わること、非均質で不均一な組成によっても変化することが解析的に明らかとなっている。したがって、燃料デブリの臨界管理ではこの不均一性による増倍率の変化を考慮しておく必要があるとともに、核計算が不均一性を正しく評価できているか確かめる必要がある。本研究では、不均一性が正しく解析出来ているかを臨界実験により検証するため、燃料棒と水穴で構成されるSTACY更新炉の炉心において、中央15
15の領域の構成要素を変えずにその配置のみを規則配列から不均一な配列に変更した際の増倍率変化を臨界水位差で測定することを試みた。事前の核計算(MCNP6、JENDL-4.0u1)によって配置変更による実効増倍率変化(上下)が大きくなる配置(増倍率で約1ドル程度、臨界水位で15cm程度の差異)で臨界実験を実施した結果について、他の計算コード・核データも使用した実験解析の結果とともに示し、核計算の不均一性の評価結果について考察する。