Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Dobashi, Kunio*; Shimizu, Yasuo*; Matsuzaki, Shinichi*; Nagamine, Takeaki*; Sato, Takahiro; Okubo, Takeru; Yokoyama, Akihito; Ishii, Yasuyuki; Kamiya, Tomihiro; Arakawa, Kazuo*; et al.
JAEA-Review 2011-043, JAEA Takasaki Annual Report 2010, P. 87, 2012/01
Matsuzaki, Shinichi*; Shimizu, Yasuo*; Dobashi, Kunio*; Nagamine, Takeaki*; Sato, Takahiro; Okubo, Takeru; Yokoyama, Akihito; Ishii, Yasuyuki; Kamiya, Tomihiro; Arakawa, Kazuo*; et al.
International Journal of Immunopathology and Pharmacology, 23(1), p.1 - 11, 2010/01
Shimizu, Yasuo*; Dobashi, Kunio*; Kusakabe, Takahiko*; Nagamine, Takeaki*; Oikawa, Masakazu*; Sato, Takahiro; Haga, Junji*; Okubo, Takeru; Ishii, Yasuyuki; Kamiya, Tomihiro; et al.
no journal, ,
no abstracts in English
Shimizu, Yasuo*; Matsuzaki, Shinichi*; Dobashi, Kunio*; Mori, Masatomo*; Sato, Takahiro; Koka, Masashi; Yokoyama, Akihito; Okubo, Takeru; Ishii, Yasuyuki; Kamiya, Tomihiro
no journal, ,
no abstracts in English
Koga, Yasuhiko*; Kaira, Kyoichi*; Yamada, Masanobu*; Dobashi, Kunio*; Matsuzaki, Shinichi*; Hisada, Takeshi*; Koka, Masashi; Yamada, Naoto; Sato, Takahiro; Yokoyama, Akihito; et al.
no journal, ,
Sato, Takahiro; Koka, Masashi; Kozai, Naofumi; Shimizu, Yasuo*; Dobashi, Kunio*; Kada, Wataru; Yokoyama, Akihito; Okubo, Takeru; Yamazaki, Akiyoshi; Ishii, Yasuyuki; et al.
no journal, ,
In the ML-EM for PIXE-CT, energy loss of incident particles and absorption of X-rays affect must be estimated using STIM-CT. This paper shows the appropriateness and the expected spatial resolution of this method are evaluated by a computer simulation and some practical experiments using 3 MeV proton microbeam with a diameter of 1m at TIARA. The PIXE-CT experiments were carried out using a dried unicellulate and human lung tissue as a test sample placed on an automatic rotation stage, which made a full turn by rotating 360 at each step of 18 in vacuum. In the simulation, X-ray yield and absorption were calculated using density distribution of two-dimensional Shepp phantom. The results of those simulation and experiments have proved that this method is effective in PIXE-CT.
Shimizu, Yasuo*; Matsuzaki, Shinichi*; Sato, Takahiro; Kamiya, Tomihiro; Okubo, Takeru; Ishii, Yasuyuki; Arakawa, Kazuo*; Nagamine, Takeaki*; Dobashi, Kunio*
no journal, ,
no abstracts in English
Dobashi, Kunio*; Shimizu, Yasuo*; Matsuzaki, Shinichi*; Ishizuka, Tamotsu*; Mori, Masatomo*; Sato, Takahiro; Koka, Masashi; Yokoyama, Akihito; Okubo, Takeru; Ishii, Yasuyuki; et al.
no journal, ,
no abstracts in English