Refine your search:     
Report No.
 - 
Search Results: Records 1-12 displayed on this page of 12
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Design of LBE spallation target for ADS Target Test Facility (TEF-T) in J-PARC

Saito, Shigeru; Obayashi, Hironari; Wan, T.; Okubo, Nariaki; Sugawara, Takanori; Endo, Shinya; Sasa, Toshinobu

Proceedings of 13th International Topical Meeting on Nuclear Applications of Accelerators (AccApp '17) (Internet), p.448 - 457, 2018/05

JAEA proposes transmutation of minor actinides by accelerator-driven systems (ADS). To obtain the data for ADS design, JAEA plans to construct the ADS Target Test Facility (TEF-T) within the framework of the J-PARC project. In TEF-T, a 250 kW proton-beam-driven LBE (Lead-Bismuth Eutectic) spallation target will be installed to prepare an irradiation database for candidate ADS structural materials. Design activities of the LBE target and target trolley have been progressed. Conceptual design of hot-cells for LBE target loop maintenance and PIE (Post Irradiation Examination) of irradiated samples have been finished. Two LBE loops were manufactured. One is a loop for TEF-T target mock-up and the other is that for collection of material corrosion characteristics in flowing LBE. Oxygen potential control systems for LBE flow have been also developed. Remote handling tests for the target exchange are underway. In this paper, current activities and studies to realize TEF-T will be presented.

Journal Articles

Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex, 2; Neutron scattering instruments

Nakajima, Kenji; Kawakita, Yukinobu; Ito, Shinichi*; Abe, Jun*; Aizawa, Kazuya; Aoki, Hiroyuki; Endo, Hitoshi*; Fujita, Masaki*; Funakoshi, Kenichi*; Gong, W.*; et al.

Quantum Beam Science (Internet), 1(3), p.9_1 - 9_59, 2017/12

The neutron instruments suite, installed at the spallation neutron source of the Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex (J-PARC), is reviewed. MLF has 23 neutron beam ports and 21 instruments are in operation for user programs or are under commissioning. A unique and challenging instrumental suite in MLF has been realized via combination of a high-performance neutron source, optimized for neutron scattering, and unique instruments using cutting-edge technologies. All instruments are/will serve in world-leading investigations in a broad range of fields, from fundamental physics to industrial applications. In this review, overviews, characteristic features, and typical applications of the individual instruments are mentioned.

Journal Articles

Field test around Fukushima Daiichi Nuclear Power Plant site using improved Ce:Gd$$_{3}$$(Al,Ga)$$_{5}$$O$$_{12}$$ scintillator Compton camera mounted on an unmanned helicopter

Shikaze, Yoshiaki; Nishizawa, Yukiyasu; Sanada, Yukihisa; Torii, Tatsuo; Jiang, J.*; Shimazoe, Kenji*; Takahashi, Hiroyuki*; Yoshino, Masao*; Ito, Shigeki*; Endo, Takanori*; et al.

Journal of Nuclear Science and Technology, 53(12), p.1907 - 1918, 2016/12

 Times Cited Count:37 Percentile:96.48(Nuclear Science & Technology)

The Compton camera was improved for use with the unmanned helicopter. Increase of the scintillator array from 4$$times$$4 to 8$$times$$8 and expanse of the distance between the two layers contributed to the improvements of detection efficiency and angular resolution, respectively. Measurements were performed over the riverbed of the Ukedo river of Namie town in Fukushima Prefecture. By programming of flight path and speed, the areas of 65 m $$times$$ 60 m and 65 m $$times$$ 180 m were measured during about 20 and 30 minutes, respectively. By the analysis the air dose rate maps at 1 m height were obtained precisely with the angular resolution corresponding to the position resolution of about 10 m from 10 m height. Hovering flights were executed over the hot spot areas for 10-20 minutes at 5-20 m height. By using the reconstruction software the $$gamma$$-ray images including the hot spots were obtained with the angular resolution same as that evaluated in the laboratory (about 10$$^{circ}$$).

Journal Articles

22A beam production of the uniform negative ions in the JT-60 negative ion source

Yoshida, Masafumi; Hanada, Masaya; Kojima, Atsushi; Kashiwagi, Mieko; Grisham, L. R.*; Hatayama, Akiyoshi*; Shibata, Takanori*; Yamamoto, Takashi*; Akino, Noboru; Endo, Yasuei; et al.

Fusion Engineering and Design, 96-97, p.616 - 619, 2015/10

 Times Cited Count:11 Percentile:67.3(Nuclear Science & Technology)

In JT-60 Super Advanced for the fusion experiment, 22A, 100s negative ions are designed to be extracted from the world largest ion extraction area of 450 mm $$times$$ 1100 mm. One of the key issues for producing such as high current beams is to improve non-uniform production of the negative ions. In order to improve the uniformity of the negative ions, a tent-shaped magnetic filter has newly been developed and tested for JT-60SA negative ion source. The original tent-shaped filter significantly improved the logitudunal uniformity of the extracted H$$^{-}$$ ion beams. The logitudinal uniform areas within a $$pm$$10 deviation of the beam intensity were improved from 45% to 70% of the ion extraction area. However, this improvement degrades a horizontal uniformity. For this, the uniform areas was no more than 55% of the total ion extraction area. In order to improve the horizontal uniformity, the filter strength has been reduced from 660 Gasus$$cdot$$cm to 400 Gasus$$cdot$$cm. This reduction improved the horizontal uniform area from 75% to 90% without degrading the logitudinal uniformity. This resulted in the improvement of the uniform area from 45% of the total ion extraction areas. This improvement of the uniform area leads to the production of a 22A H$$^{-}$$ ion beam from 450 mm $$times$$ 1100 mm with a small amount increase of electron current of 10%. The obtained beam current fulfills the requirement for JT-60SA.

Journal Articles

Site occupancy of interstitial deuterium atoms in face-centred cubic iron

Machida, Akihiko; Saito, Hiroyuki; Sugimoto, Hidehiko*; Hattori, Takanori; Sano, Asami; Endo, Naruki*; Katayama, Yoshinori; Iizuka, Riko*; Sato, Toyoto*; Matsuo, Motoaki*; et al.

Nature Communications (Internet), 5, p.5063_1 - 5063_6, 2014/09

 Times Cited Count:55 Percentile:86.02(Multidisciplinary Sciences)

Iron hydride FeH$$_x$$, is thermodynamically stable only at high hydrogen pressure of several GPa. To investigate the hydrogenation process and hydrogen state in iron hydride, it is necessary to carry out the in-situ measurement under high pressure and high temperature. In this study, we performed the in-situ neutron diffraction measurement of Fe-D system using the high pressure neutron diffractometer PLANET in the MLF, J-PARC, and determined the deuterium occupying sites and occupancies in fcc-FeD$$_x$$. We found the minor occupation of tetrahedral sites under high pressure and high temperature. We considered the mechanism of the minor occupation based on the Quantum-mechanical calculation.

Journal Articles

Comparison of dosimetry by the realistic patient head phantom and by the patient's brain, and the JCDS calculation; A Clinical dosimetry study

Endo, Kiyoshi*; Matsumura, Akira*; Yamamoto, Tetsuya*; Nose, Tadao*; Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Torii, Yoshiya; Kashimura, Takanori*; Otake, Shinichi*

Research and Development in Neutron Capture Therapy, p.425 - 430, 2002/09

Using the Rapid Prototyping Technique, we produced a realistic phantom as a formative model of a patient head. This realistic phantom will contribute to verification of our planning system. However, cross-correlation among the calculations using the JAERI Computational Dosimetry System (JCDS), the realistic phantom, and the in vivo measurements were not fully completed because of the difficulty involved in modeling a post-surgical brain and a thermal neutron shield. The experimental simulation technique using the realistic phantom is a useful tool for more reliable dose planning for the intraoperative BNCT.

Oral presentation

Structural studies of iron deuteride by in-situ neutron diffraction measurements under high temperature and high pressure

Machida, Akihiko; Saito, Hiroyuki; Hattori, Takanori; Sano, Asami; Endo, Naruki; Watanuki, Tetsu; Katayama, Yoshinori; Aoki, Katsutoshi; Sato, Toyoto*; Matsuo, Motoaki*; et al.

no journal, , 

no abstracts in English

Oral presentation

In situ neutron diffraction measurement on deuterization process of iron at high pressure and high temperature

Machida, Akihiko; Saito, Hiroyuki; Hattori, Takanori; Sano, Asami; Endo, Naruki*; Watanuki, Tetsu; Katayama, Yoshinori; Iizuka, Riko*; Sato, Toyoto*; Matsuo, Motoaki*; et al.

no journal, , 

Iron hydride FeH$$_x$$, is thermodynamically stable only at high hydrogen pressure of several GPa. Three hydride phases, bcc-FeH$$_x$$ ($$x < 0.05$$), dhcp-FeH$$_x$$ ($$x sim 1$$), and fcc-FeH$$_x$$ ($$x = 0 - 1$$) were confirmed at 300-2000 K and 0-20 GPa. In situ neutron diffraction measurement on their deutrides have not been reported yet. A high pressure neutron diffractometor, PLANET, constructed at Materials and Life Science Experimental Facility at J-PARC, enables us to perform in situ neutoron diffraction measurements on deuterization process of metals at high pressure and high temperature. With PLANET, the deuteration process of iron was investigated at a pressure of about 7 GPa and temperatures up to about 1000 K. This in situ measurement was successfully made using a deuterization reaction cell developed for neutron diffraction measurement. We observed the bcc-fcc transition of pure iron around 800 K and successive deuterization of fcc-Fe around 870 K.

Oral presentation

${it In situ}$ neutron diffraction measurement on the deuterization process of Fe at high temperature and high pressure

Machida, Akihiko; Saito, Hiroyuki; Hattori, Takanori; Sano, Asami; Endo, Naruki; Watanuki, Tetsu; Katayama, Yoshinori; Iizuka, Riko*; Sato, Toyoto*; Matsuo, Motoaki*; et al.

no journal, , 

no abstracts in English

Oral presentation

Study of deuterization reaction process of iron at high pressure using in situ neutron diffraction measurement

Machida, Akihiko; Saito, Hiroyuki; Hattori, Takanori; Sano, Asami; Endo, Naruki; Watanuki, Tetsu; Katayama, Yoshinori; Iizuka, Riko*; Sato, Toyoto*; Matsuo, Motoaki*; et al.

no journal, , 

no abstracts in English

Oral presentation

Development of energy recognizable type gamma camera mounted on the unmanned helicopter, 3; Field test around the Fukushima Daiichi NPP site

Shikaze, Yoshiaki; Torii, Tatsuo; Shimazoe, Kenji*; Jiang, J.*; Takahashi, Hiroyuki*; Kurosawa, Shunsuke*; Kamada, Kei*; Yoshikawa, Akira*; Yoshino, Masao*; Ito, Shigeki*; et al.

no journal, , 

no abstracts in English

Oral presentation

Development of energy recognizable type gamma camera mounted on the unmanned helicopter II, 2; Field test around the Fukushima Daiichi NPP site

Shikaze, Yoshiaki; Torii, Tatsuo; Nishizawa, Yukiyasu; Yoshida, Mami*; Shimazoe, Kenji*; Jiang, J.*; Takahashi, Hiroyuki*; Kurosawa, Shunsuke*; Kamada, Kei*; Yoshikawa, Akira*; et al.

no journal, , 

no abstracts in English

12 (Records 1-12 displayed on this page)
  • 1