Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Yano, Yasuhide; Otsuka, Satoshi; Yamashita, Shinichiro; Ogawa, Ryuichiro; Sekine, Manabu; Endo, Toshiaki; Yamagata, Ichiro; Sekio, Yoshihiro; Tanno, Takashi; Uwaba, Tomoyuki; et al.
JAEA-Research 2013-030, 57 Pages, 2013/11
It is necessary to develop the fast reactor core materials, which can achieve high-burnup operation improving safety and economical performance. Ferritic steels are expected to be good candidate core materials to achieve this objective because of their excellent void swelling resistance. Therefore, oxide dispersion strengthened (ODS) ferritic steel and 11Cr-ferritic/martensitic steel (PNC-FMS) have been respectively developed for cladding and wrapper tube materials in Japan Atomic Energy Agency. In this study, the effects of fast neutron irradiation on mechanical properties and microstructure of 9Cr-and 12Cr-ODS steel claddings for fast reactor were investigated. Specimens were irradiated in the experimental fast reactor Joyo using the CMIR-6 at temperatures between 420 and 835C to fast neutron doses ranging from 16 to 33 dpa. The post-irradiation ring tensile tests were carried out at irradiation temperatures.
Yamamoto, Tetsuya*; Matsumura, Akira*; Nakai, Kei*; Shibata, Yasushi*; Endo, Kiyoshi*; Sakurai, Fumio; Kishi, Toshiaki; Kumada, Hiroaki; Yamamoto, Kazuyoshi; Torii, Yoshiya
Applied Radiation and Isotopes, 61(5), p.1089 - 1093, 2004/11
Times Cited Count:53 Percentile:94.32(Chemistry, Inorganic & Nuclear)no abstracts in English
Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Torii, Yoshiya; Endo, Kiyoshi*; Yamamoto, Tetsuya*; Matsumura, Akira*; Uchiyama, Junzo; Nose, Tadao*
JAERI-Tech 2002-092, 23 Pages, 2002/12
Thermal neutron flux is determined using the gold wires in current BNCT irradiation, so evaluation of arbitrary points after the irradiation is limited in the quantity of these detectors. In order to make up for the weakness, dose estimation of a patient is simulated by a computational dose calculation supporting system. In another way without computer simulation, a medical irradiation condition can be replicate experimentally using of realistic phantom which was produced from CT images by rapid prototyping technique. This phantom was irradiated at a same JRR-4 neutron beam as clinical irradiation condition of the patient and the thermal neutron distribution on the brain surface was measured in detail. This experimental evaluation technique using a realistic phantom is applicable to in vitro cell irradiation experiments for radiation biological effects as well as in-phantom experiments for dosimetry under the nearly medical irradiation condition of patient.
Endo, Kiyoshi*; Matsumura, Akira*; Yamamoto, Tetsuya*; Nose, Tadao*; Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Torii, Yoshiya; Kashimura, Takanori*; Otake, Shinichi*
Research and Development in Neutron Capture Therapy, p.425 - 430, 2002/09
Using the Rapid Prototyping Technique, we produced a realistic phantom as a formative model of a patient head. This realistic phantom will contribute to verification of our planning system. However, cross-correlation among the calculations using the JAERI Computational Dosimetry System (JCDS), the realistic phantom, and the in vivo measurements were not fully completed because of the difficulty involved in modeling a post-surgical brain and a thermal neutron shield. The experimental simulation technique using the realistic phantom is a useful tool for more reliable dose planning for the intraoperative BNCT.
Endo, Kiyoshi*; Nakai, Kei*; Yoshida, Fumiyo*; Shirakawa, Shin*; Yamamoto, Tetsuya*; Matsumura, Akira*; Sawahata, Hiroyuki*; Kawate, Minoru*; Saito, Kimiaki; Kumada, Hiroaki; et al.
no journal, ,
no abstracts in English