Refine your search:     
Report No.
 - 
Search Results: Records 1-7 displayed on this page of 7
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Feasibility study of sublimation type $$^{99m}$$Tc master-milker; Comparison with PZC based wet method

Ishitsuka, Etsuo; Yamabayashi, Hisamichi*; Tanase, Masakazu*; Fujisaki, Saburo*; Sato, Norihito*; Hori, Naohiko; Awaludin, R.*; Gunawan, A. H.*; Lubis, H.*; Mutalib, A.*

JAEA-Technology 2011-019, 18 Pages, 2011/06

JAEA-Technology-2011-019.pdf:2.61MB

Feasibility study of sublimation type $$^{99m}$$Tc master-milker was carried out as a $$^{99}$$Mo/$$^{99m}$$T production development with the JMTR. As the feasibility study, the experimental equipment for sublimation method and wet method with PZC based $$^{99m}$$Tc solution were tentatively manufactured, and their properties as the master-milker were investigated by comparing two methods with each other. As a result, it was found that the $$^{99m}$$Tc recovery rate and process time of the sublimation method were about 80% and 1.5 hour, respectively, and the similar values were observed with the wet method. Superior points of the sublimation method are easier operation and reusability of the used MoO$$_{3}$$ comparing with the wet method. On the other hand, disadvantageous point is that the $$^{99m}$$Tc recovery rate decreases with the increase of treating amount of MoO$$_{3}$$.

Journal Articles

Super-parallel simulation systems for sophisticated radiation therapy

Saito, Kimiaki; Saito, Hidetoshi*; Kunieda, Etsuo*; Narita, Yuichiro*; Myojoyama, Atsushi*; Fujisaki, Tatsuya*; Kawase, Takatsugu*; Kaneko, Katsutaro*; Ozaki, Masahiro*; Deloar, H. M.*; et al.

Joho Shori, 48(10), p.1081 - 1088, 2007/10

no abstracts in English

Journal Articles

Investigations of different kilovoltage X-ray energy for three-dimensional converging stereotactic radiotherapy system; Monte Carlo simulations with CT data

Deloar, H. M.*; Kunieda, Etsuo*; Kawase, Takatsugu*; Tsunoo, Takanori*; Saito, Hidetoshi*; Ozaki, Masahiro*; Saito, Kimiaki; Takagi, Shunji*; Sato, Osamu*; Fujisaki, Tatsuya*; et al.

Medical Physics, 33(12), p.4635 - 4642, 2006/12

 Times Cited Count:13 Percentile:39.28(Radiology, Nuclear Medicine & Medical Imaging)

We are investigating three-dimensional converging stereotactic radiotherapy for small lung tumors with better dose homogeneity at the target. A computed tomography radiotherapy was simulated with BEAMnrc X-ray energy of 147.5, 200, 300, and 500 kilovoltage system was validated by comparing calculated and measured percentage of depth dose in a water phantom for the energy of 120 and 147.5 kVp. A thorax phantom and CT data from lung tumors compare dose homogeneities of kVp energies with MV energies of 4, 6, and 10 MV. Three non-coplanar arcs of the target were employed. The Monte Carlo dose data format was converted to the XiO RTP format to compare dose homogeneity, differential, and integral dose volume histograms of kVp and MV energies. In terms of dose homogeneity and DVHs, dose distributions at the target of all kVp energies with the thorax phantom were better than MV energies, with mean dose absorption at the ribs of 100%, 85%, 50%, 30% for 147.5, 200, 300, and 500 kVp, respectively. Considering dose distributions and reduction of the enhanced dose absorption at the ribs, a minimum of 500 kVp is suitable for the lung kVp 3DCSRT system.

Journal Articles

Dose calculation system for remotely supporting radiotherapy

Saito, Kimiaki; Kunieda, Etsuo*; Narita, Yuichiro*; Kimura, Hideo; Hirai, Masaaki*; Deloar, H. M.*; Kaneko, Katsutaro*; Ozaki, Masahiro*; Fujisaki, Tatsuya*; Myojoyama, Atsushi*; et al.

Radiation Protection Dosimetry, 116(1-4), p.190 - 195, 2005/12

 Times Cited Count:2 Percentile:17.6(Environmental Sciences)

A dose calculation system for providing accurate dose distribution in a patient body is under developing for supporting radiotherapy using photons and electrons. In this system, a sophisticated human model, a precise accelerator head model, and a Monte Carlo calculation will be utilized to perform realistic simulation. The dose distribution is calculated by this system on the ITBL computer at the dose calculation center, and the related data are transferred through a network. This system is intended to support the quality assurance of current treatments carried out in Japan. Further, this system is planned to apply to advanced radiotherapy. The project started on November 2003 and is scheduled to continue for five years. Prototypes of some parts constituting the system have been already developed, and the fundamental features on the radiation fields have been investigated. On the basis of the fundamental investigation, the final system will be designed and constructed.

Journal Articles

Development of the unattended spent fuel flow monitoring system for the high temperature engineering test reactor safeguards use

Nakagawa, Shigeaki; Kikuchi, Takayuki; Fujisaki, Shingo; Yamashita, Kiyonobu; H.O.Menlove*

IAEA-SM-351/89, 15 Pages, 1997/00

no abstracts in English

Journal Articles

The ITER-QUELL, a quench propagation experiment on a long length CICC with central channel

Anghel, A.*; Takahashi, Yoshikazu; Smith, S.*; Pourrahimi, S.*; Zhelamskij, M.*; Blau, B.*; Fuchs, A.*; Heer, B.*; Hamada, Kazuya; Fujisaki, H.*; et al.

Fusion Technology 1996, p.185 - 190, 1996/00

no abstracts in English

Oral presentation

Development of the Monte Carlo dose calcualtion system IMAGINE for remotely supporting radiation therapy

Saito, Kimiaki; Kunieda, Etsuo*; Narita, Yuichiro*; Kaneko, Katsutaro*; Hirai, Masaaki*; Oku, Yohei*; Deloar, H. M.*; Fujisaki, Tatsuya*; Myojoyama, Atsushi*; Saito, Hidetoshi*

no journal, , 

no abstracts in English

7 (Records 1-7 displayed on this page)
  • 1