Kato, Atsushi; Negishi, Kazuo; Iwasaki, Mikinori*; Akiyama, Yo*; Furue, Mamoru*; Okayasu, Takafumi*
no journal, ,
Steel plate reinforced concrete structure are adopted as the JSFR containment vessel to shorten a construction period. This reports experimental investigation of SCCV basic structural property.
Negishi, Kazuo; Hara, Hiroyuki*; Furue, Mamoru*; Sawamoto, Yoshikazu*
no journal, ,
The JSFR adopts SCCV for the quality improvement and reduction of construction term. For commercialization of JSFR, we have carried out the research and development of not only the study on SCCV structure and construction term at the site but also the material strength test and analysis. These series presentation show the results. In this presentation, the results of the experiments and evaluation of out-of-plane shear strength of SCCV structure reinforced by tie bars are shown.