Refine your search:     
Report No.
 - 
Search Results: Records 1-9 displayed on this page of 9
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Cable twist pitch variation in Nb$$_{3}$$Sn conductors for ITER toroidal field coils in Japan

Takahashi, Yoshikazu; Nabara, Yoshihiro; Hemmi, Tsutomu; Nunoya, Yoshihiko; Isono, Takaaki; Hamada, Kazuya; Matsui, Kunihiro; Kawano, Katsumi; Koizumi, Norikiyo; Oshikiri, Masayuki; et al.

IEEE Transactions on Applied Superconductivity, 23(3), p.4801504_1 - 4801504_4, 2013/06

 Times Cited Count:11 Percentile:50.46(Engineering, Electrical & Electronic)

Japan Atomic Energy Agency (JAEA) is the first to start the mass production of the TF conductors in March 2010 among the 6 parties who are procuring TF conductors in the ITER project. The height and width of the TF coils are 14 m and 9 m, respectively. The conductor is cable-in-conduit conductor (CICC) with a central spiral. A circular multistage superconducting cable is inserted into a circular stainless steel jacket with a thickness of 2 mm. A total of 900 Nb$$_{3}$$Sn strands and 522 copper strands are cabled around the central spiral and the cable is inserted into a round-in-round stainless steel jacket. It was observed that the cabling pitch of the destructive sample is longer than the original pitch at cabling. The JAEA carried out the tensile tests of the cable and the measurement of the cable rotation during the insertion to investigate the cause of the elongation. The cause of elongation was clarified and the results will be described in this paper.

Journal Articles

Mass production of Nb$$_{3}$$Sn conductors for ITER toroidal field coils in Japan

Takahashi, Yoshikazu; Isono, Takaaki; Hamada, Kazuya; Nunoya, Yoshihiko; Nabara, Yoshihiro; Matsui, Kunihiro; Hemmi, Tsutomu; Kawano, Katsumi; Koizumi, Norikiyo; Oshikiri, Masayuki; et al.

IEEE Transactions on Applied Superconductivity, 22(3), p.4801904_1 - 4801904_4, 2012/06

 Times Cited Count:7 Percentile:41.31(Engineering, Electrical & Electronic)

Japan Atomic Energy Agency is the first to start the mass production of the TF conductors in Phase IV in March 2010 among the 6 parties who are procuring TF conductors in the ITER project. The conductor is cable-in-conduit conductor with a central spiral. A total of 900 Nb$$_{3}$$Sn strands and 522 copper strands are cabled around the central spiral and then wrapped with stainless steel tape whose thickness is 0.1 mm. Approximately 60 tons of Nb$$_{3}$$Sn strands were manufactured by the two suppliers in December 2010. This amount corresponds to approximately 55% of the total contribution from Japan. Approximately 30% of the total contribution from Japan was completed as of February 2011. JAEA is manufacturing one conductor per month under a contract with two Japanese companies for strands, one company for cabling and one company for jacketing. This paper summarizes the technical developments including a high-level quality assurance. This progress is a significant step in the construction of the ITER machine.

Journal Articles

Analyses of absorbed dose to tooth enamel against external photon exposure

Takahashi, Fumiaki; Yamaguchi, Yasuhiro; Iwasaki, Midori*; Miyazawa, Chuzo*; Hamada, Tatsuji*; Funabiki, Jun*; Saito, Kimiaki

Radiation Protection Dosimetry, 103(2), p.125 - 130, 2003/01

 Times Cited Count:4 Percentile:31.59(Environmental Sciences)

Absorbed dose to tooth enamels against external photon exposure was examined by the Electron Spin Resonance (ESR) dosimetry using tooth samples placed in a realistic physical phantom. Dose to teeth region was also measured with thermo-luminescence dosimeters (TLDs). A voxel-type phantom was constructed from CT images of the physical phantom. Monte Carlo calculations with this voxel-type phantom were performed to analyse the results of the experiments. The obtained data in this study were compared to the enamel doses, which were calculated with a modified MIRD-type and already given in a previous paper. The results suggested that the conversion factors from enamel dose to organ doses obtained by the modified MIRD-type phantom are to be applicable for retrospective individual dose assessments by the ESR dosimetry. The analysis, however, indicated that the size and figure of the head can affect the enamel dose for low photon energy region below 100keV.

Journal Articles

Conversion from tooth enamel dose to organ doses for the electron spin resonance dosimetry

Takahashi, Fumiaki; Yamaguchi, Yasuhiro; Iwasaki, Midori*; Miyazawa, Chuzo*; Hamada, Tatsuji*; Saito, Kimiaki

Journal of Nuclear Science and Technology, 39(9), p.964 - 971, 2002/09

 Times Cited Count:6 Percentile:39.48(Nuclear Science & Technology)

Conversion from tooth enamel dose to organ doses was analyzed to establish a method of retrospective individual dose assessment against external photon exposure by the Electron Spin Resonance (ESR) dosimetry. Dose to tooth enamel was obtained by Monte Carlo calculations using a modified MIRD-type phantom. The calculated tooth enamel doses were verified by measurements with thermo-luminescence dosimeters inserted in a physical head phantom. Energy and angular dependences of tooth enamel dose were compared with those of other organ doses. Additional Monte Carlo calculations were performed to study the effects of human model on the tooth enamel dose with a voxel-type phantom, which was based on CT images of the physical phantom. The data derived with the modified MIRD-type phantom were applied to convert from tooth enamel dose to organ doses against external photon exposure in a hypothesized field, where scattered radiations were taken into account. The results indicated that energy distribution of photons incident to a human body should be required to evaluate precisely individual dose by the ESR dosimetry using teeth.

Journal Articles

Analysis of absorbed dose to tooth enamel for ESR dosimetry

Takahashi, Fumiaki; Yamaguchi, Yasuhiro; Saito, Kimiaki; Iwasaki, Midori*; Miyazawa, Chuzo*; Hamada, Tatsuji*; Funabiki, Jun*

Journal of Nuclear Science and Technology, 39(Suppl.2), p.1314 - 1317, 2002/08

An analysis of dose to tooth enamel was carried out to develop a method that can predict the organdose and effective dose by the Electron Spin Resonance (ESR) dosimetry using teeth for external photon exposure. Absorbed dose to tooth enamel were obtained with Monte Carlo calculations using EGS4 code with a mathematical human model, which has a newly defined teeth-part. Experiments were also carried out to investigate the dose at the tooth area with a physical head phantom. The calculated doses to tooth enamel were, however, less than the measured doses with the TLDs for the case of photon incidence from the back of a human body. Then, a computational human model, called a “Voxel (Volume-pixel) type" phantom was constructed based upon a computed topography (CT) image of the physical head phantom used in the experiments.The additional Monte Carlo calculations were performed to verify the results in the experiments with the EGS4 in conjunction with user's code UCPIXEL and the Voxel type phantom.

Journal Articles

Relations between tooth enamel dose and organ doses for the Electron Spin Resonance dosimetry against external photon exposure

Takahashi, Fumiaki; Yamaguchi, Yasuhiro; Iwasaki, Midori*; Miyazawa, Chuzo*; Hamada, Tatsuji*

Radiation Protection Dosimetry, 95(2), p.101 - 108, 2001/09

 Times Cited Count:27 Percentile:85.67(Environmental Sciences)

An analysis of doses to tooth enamel and to organs was carried out to develop a method that can predict the organ doses and the effective dose by the Electron Spin Resonance (ESR) dosimetry using tooth samples for external photon exposure. Absorbed dose to tooth enamel and organ doses were obtained by Monte Carlo calculations using EGS4 code in combination with a mathematical human model with a newly defined teeth-part. The calculations gave quantitative relations between tooth enamel dose and organ doses for some cases of external photon exposure. It was also found that tooth enamel dose depends more significantly on energy of incident photons than the other organ dose or the effective dose. The obtained data are to be useful for the assessment of individual dose in past exposure events by the ESR dosimetry with tooth enamel.

Journal Articles

Analysis of dose in teeth for estimation of effective dose by the electron spin resonance (ESR) dosimetry using dental enamels

Takahashi, Fumiaki; Yamaguchi, Yasuhiro; Saito, Kimiaki; Iwasaki, Midori*; Miyazawa, Chuzo*; Hamada, Tatsuji*

KEK Proceedings 2000-20, p.48 - 55, 2000/12

no abstracts in English

Journal Articles

Radiation between teeth-dose and effective dose for external photon exposure

Takahashi, Fumiaki*; Yamaguchi, Yasuhiro; Iwasaki, Midori*; Miyazawa, Chuzo*; Hamada, Tatsuji*

Proceedings of 10th International Congress of the International Radiation Protection Association (IRPA-10) (CD-ROM), 5 Pages, 2000/05

no abstracts in English

Oral presentation

Mass production technology of ITER conductors; Investigation of twist pitch variation

Takahashi, Yoshikazu; Nabara, Yoshihiro; Hemmi, Tsutomu; Nunoya, Yoshihiko; Isono, Takaaki; Oshikiri, Masayuki; Tsutsumi, Fumiaki; Uno, Yasuhiro; Hamada, Kazuya; Shibutani, Kazuyuki*; et al.

no journal, , 

In the ITER project, Japan Atomic Energy Agency (JAEA) is the first to start the mass production of the TF conductors in March 2010 among the 6 parties who are procuring TF conductors in the ITER project. The height and width of the TF coils are 14 m and 9 m, respectively. The conductor is cable-in-conduit conductor (CICC) with a central spiral. A circular multistage superconducting cable is inserted into a circular stainless steel jacket with a thickness of 2 mm. A total of 900 Nb$$_{3}$$Sn strands and 522 copper strands are cabled around the central spiral and the cable is inserted into a round-in-round stainless steel jacket. It was observed that the cabling pitch of the destructive sample is longer than the original pitch at cabling. The JAEA carried out the tensile tests of the cable and the measurement of the cable rotation during the insertion to investigate the cause of the elongation. The cause of elongation was clarified and the results will be described in this paper.

9 (Records 1-9 displayed on this page)
  • 1