Refine your search:     
Report No.
 - 
Search Results: Records 1-6 displayed on this page of 6
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Test beam-line for laser-driven proton therapy

Sakaki, Hironao; Nishiuchi, Mamiko; Hori, Toshihiko; Bolton, P.; Yogo, Akifumi; Ogura, Koichi; Sagisaka, Akito; Pirozhkov, A. S.; Orimo, Satoshi; Kondo, Kiminori; et al.

Proceedings of 7th Annual Meeting of Particle Accelerator Society of Japan (DVD-ROM), p.312 - 315, 2010/08

The beam transport test is carried out through the test beam line of the laser-driven proton accelerator which consists of the phase rotation cavity, PMQ, and bending magnet. The laser system used is J-KAREN at JAEA. The final transmitted bunch duration and transverse profile are well predicted by the PARMILA particle transport code by assuming relatively low initial current of the proton beam. The most probable explanation for this is the space charge neutralization by the laser-plasma-electrons.

Journal Articles

Measured and simulated transport of 1.9 MeV laser-accelerated proton bunches through an integrated test beam line at 1 Hz

Nishiuchi, Mamiko; Sakaki, Hironao; Hori, Toshihiko; Bolton, P.; Ogura, Koichi; Sagisaka, Akito; Yogo, Akifumi; Mori, Michiaki; Orimo, Satoshi; Pirozhkov, A. S.; et al.

Physical Review Special Topics; Accelerators and Beams, 13(7), p.071304_1 - 071304_7, 2010/07

 Times Cited Count:25 Percentile:79.43(Physics, Nuclear)

A laser-driven repetition-rated 1.9 MeV proton beam line composed of permanent quadrupole magnets (PMQs), a radio frequency (rf) phase rotation cavity, and a tunable monochromator is developed to evaluate and to test the simulation of laser-accelerated proton beam transport through an integrated system for the first time. In addition, the proton spectral modulation and focusing behavior of the rf phase rotationcavity device is monitored with input from a PMQ triplet. In the 1.9 MeV region we observe very weakproton defocusing by the phase rotation cavity. The final transmitted bunch duration and transverse profile are well predicted by the PARMILA particle transport code. The transmitted proton beam duration of 6 ns corresponds to an energy spread near 5% for which the transport efficiency is simulated to be 10%. The predictive capability of PARMILA suggests that it can be useful in the design of future higher energy transport beam lines as part of an integrated laser-driven ion accelerator system.

Journal Articles

Laser-driven proton accelerator for medical application

Nishiuchi, Mamiko; Sakaki, Hironao; Hori, Toshihiko; Bolton, P.; Ogura, Koichi; Sagisaka, Akito; Yogo, Akifumi; Mori, Michiaki; Orimo, Satoshi; Pirozhkov, A. S.; et al.

Proceedings of 1st International Particle Accelerator Conference (IPAC '10) (Internet), p.88 - 90, 2010/05

The concept of a compact ion particle accelerator has become attractive in view of recent progress in laser-driven ion acceleration. We report here the recent progress in the laser-driven proton beam transport at the Photo Medical Research Center (PMRC) at JAEA, which is established to address the challenge of laser-driven ion accelerator development for ion beam cancer therapy.

Journal Articles

Construction of the J-PARC L3BT control system

Shen, G.; Watanabe, Kazuhiko*; Kato, Yuko; Sakaki, Hironao; Sako, Hiroyuki; Ito, Yuichi; Yoshikawa, Hiroshi; Hanawa, Katsushi*; Mizuno, Seiji*

Proceedings of 3rd Annual Meeting of Particle Accelerator Society of Japan and 31st Linear Accelerator Meeting in Japan (CD-ROM), p.364 - 366, 2006/00

The control system of J-PARC project is under construction. After almost finishing the hardware installation of the L3BT section, an online device commissioning was performed for magnet power supply, stepping motor and vacuum system. Many components for device control have already been developed separately, but not integrated together yet. It is the first experience to combine all the components, including core software for a front-end IO controller, an EPICS run-time database, and a remote graphic user interface. This paper describes the detail of the recent construction status of the L3BT control system, including component development, system integration, and device commissioning.

Oral presentation

Towards the laser-driven proton accelerator for cancer therapy; Benchmark test of the PARMILA code at the transport and irradiation test beam line

Nishiuchi, Mamiko; Sakaki, Hironao; Hori, Toshihiko; Bolton, P.; Ogura, Koichi; Yogo, Akifumi; Pirozhkov, A. S.; Sagisaka, Akito; Orimo, Satoshi; Mori, Michiaki; et al.

no journal, , 

no abstracts in English

Oral presentation

Prototype of beam transport line for laser-driven proton therapy

Sakaki, Hironao; Nishiuchi, Mamiko; Hori, Toshihiko; Kondo, Kiminori; Ogura, Koichi; Yogo, Akifumi; Sagisaka, Akito; Orimo, Satoshi; Mori, Michiaki; Tampo, Motonobu; et al.

no journal, , 

We constructed prototype transportation system of the laser driven 2.0MeV by using nuclear power mechanism J-KAREN laser, and we measured and analyzed this beam line.

6 (Records 1-6 displayed on this page)
  • 1