Watanabe, Kenichi*; Sugai, Yusuke*; Hasegawa, Sota*; Tanaka, Seishiro*; Hitomi, Keitaro*; Nogami, Mitsuhiro*; Shinohara, Takenao; Su, Y. H.; Parker, J. D.*; Kockelmann, W.*
Scientific Reports (Internet), 14, p.25224_1 - 25224_13, 2024/10
Times Cited Count:0 Percentile:0.00(Multidisciplinary Sciences)Nemoto, Takahiro; Fujiwara, Yusuke; Arakawa, Ryoki; Choyama, Yuya; Nagasumi, Satoru; Hasegawa, Toshinari; Yokoyama, Keisuke; Watanabe, Masashi; Onishi, Takashi; Kawamoto, Taiki; et al.
JAEA-Technology 2024-003, 17 Pages, 2024/06
In order to investigate the cause of the increase in differential pressure in the primary helium circulator filter that occurred during the RS-14 cycle, a clogged filter was investigated. As a result of the investigation, deposits caused by silicone oil were confirmed on the surface of the filter element. These results revealed that the cause of filter clogging was silicone oil mixed into the primary system due to performance deterioration of the charcoal filter in the gas circulator of primary helium purification system. As a measure to prevent the recurrence of this event, in addition to the conventional management based on operating hours for replacing of charcoal filter in the gas circulator of primary helium purification system, we have established a new replacement plan for every three years.
Hasegawa, Toshinari; Nagasumi, Satoru; Nemoto, Takahiro; Nakajima, Kunihiro; Yokoyama, Keisuke; Fujiwara, Yusuke; Arakawa, Ryoki; Iigaki, Kazuhiko; Inoi, Hiroyuki; Kawamoto, Taiki
Proceedings of 2024 International Congress on Advanced in Nuclear Power Plants (ICAPP 2024) (Internet), 10 Pages, 2024/06
The filter element of the primary gas circulators (PGC) in High Temperature engineering Test Reactor (HTTR) and its deposits were investigated by Scanning Electron Microscope (SEM) observation and Energy Dispersive X-ray spectroscopy (EDX) analysis to find the cause of the increase of the filter differential pressure during the operation in 2021. SEM observation showed that the clumpy deposits and fibrous deposits smaller than the filtration pore size and the rod-shaped deposits larger than the pore size were present on the filter element. EDX analysis showed that the clumpy deposits and fibrous deposits could include silicone oil in the primary helium purification system (PHPS) gas circulators and that the rod-shaped deposits were thermal insulators inside of the co-axial double pipes in the primary cooling system. It is considered that silicone oil leaked from the PHPS gas circulators due to deterioration in the absorption performance of the activated charcoal filter. Next, it could be vaporized and reach PGC's filter element after passing through the reactor core. Since those deposits including silicone oil were present over the entire surface of the filter element, the filter differential pressure could be increased due to a reduction in the pore size and a rise in its flow resistance. The thermal insulator was unrelated to filter clogging because it was present mainly in the lower part of the filter element. Therefore, silicone oil could increase the filter differential pressure, and the graphite powder, which is the cause of the previous issue was unrelated.
Watanabe, Kenichi*; Sugai, Yusuke*; Hasegawa, Sota*; Hitomi, Keitaro*; Nogami, Mitsuhiro*; Shinohara, Takenao; Su, Y. H.; Parker, J. D.*; Kockelmann, W.*
Sensors and Materials, 36(1), p.149 - 154, 2024/01
Times Cited Count:2 Percentile:83.81(Instruments & Instrumentation)Saga, Ryo*; Matsuya, Yusuke; Sato, Hikari*; Hasegawa, Kazuki*; Obara, Hideki*; Komai, Fumio*; Yoshino, Hironori*; Aoki, Masahiko*; Hosokawa, Yoichiro*
Radiotherapy and Oncology, p.109444_1 - 109444_9, 2023/00
Times Cited Count:3 Percentile:49.33(Oncology)When treating non-small cell lung cancer (NSCLC), stereotactic body radiotherapy (SBRT) with high-dose irradiation is often utilized. The fractionation schemes and curative effects can be evaluated by mathematical models for predicting cell survival curve. Such model parameters can be determined from in vitro experiment, but they are empirically determined based on experiences in clinics. As such, there is a large gap between in vitro and clinical study. As such background, translational study between in vitro cell survival and clinical curative effects is necessary. In this study, explicitly considering existence of cancer stem-like cells (CSCs), we developed an all-in-one model for predicting both in vitro cell survival and clinical curative effects (integrated microdosimetric-kinetic (IMK) model) and performed retrospective evaluation of clinical outcomes following SBRT for NSCLC in Hirosaki University Hospital. As a result, the IMK model successfully reproduced both in vitro cell survival and the tumor control probability with various fractionation schemes (i.e., 6-10 Gy per fraction). The developed model would contribute on precisely understanding the impact of CSCs on curative effects after SBRT for NSCLC with high precision.
Saga, Ryo*; Matsuya, Yusuke; Takahashi, Rei*; Hasegawa, Kazuki*; Date, Hiroyuki*; Hosokawa, Yoichiro*
Scientific Reports (Internet), 11(1), p.8258_1 - 8258_10, 2021/04
Times Cited Count:4 Percentile:36.52(Multidisciplinary Sciences)Hyaluronan synthesis inhibitor 4-methylumbelliferone (4-MU) is a candidate of radiosensitizers in X-ray therapy. The curative effects under such 4-MU administration have been investigated in vitro; however, the radiosensitizing mechanisms remain unclear. Here, we investigated the radiosensitizing effects under 4-MU treatment from cell experiments and model estimations. We generated experimental surviving fractions of human fibrosarcoma cells (HT1080) after 4-MU treatment combined with X-ray irradiation. Meanwhilst, we also modelled the pharmacological effects of 4-MU treatment and theoretically analyzed the synergetic effects between 4-MU treatment and X-ray irradiation. The results show that the enhancement of cell killing by 4-MU treatment is the greatest in the intermediate dose range of around 4 Gy, which indicates the involvement of intercellular communication. In addition, the oxidative stress level, which leads to DNA damage induction, significantly increased under 4-MU treatment, and the radiosensitization by 4-MU can be suppressed by the inhibitors for intercellular communication. These findings suggest that the synergetic effects between 4-MU treatment and irradiation are predominantly attributed to intercellular communication and provide more efficient tumour control than conventional X-ray therapy.
Yang, Z. H.*; Kubota, Yuki*; Corsi, A.*; Yoshida, Kazuki; Sun, X.-X.*; Li, J. G.*; Kimura, Masaaki*; Michel, N.*; Ogata, Kazuyuki*; Yuan, C. X.*; et al.
Physical Review Letters, 126(8), p.082501_1 - 082501_8, 2021/02
Times Cited Count:55 Percentile:96.38(Physics, Multidisciplinary)A quasifree (,
) experiment was performed to study the structure of the Borromean nucleus
B, which had long been considered to have a neutron halo. By analyzing the momentum distributions and exclusive cross sections, we obtained the spectroscopic factors for
and
orbitals, and a surprisingly small percentage of 9(2)% was determined for
. Our finding of such a small
component and the halo features reported in prior experiments can be explained by the deformed relativistic Hartree-Bogoliubov theory in continuum, revealing a definite but not dominant neutron halo in
B. The present work gives the smallest
- or
-orbital component among known nuclei exhibiting halo features and implies that the dominant occupation of
or
orbitals is not a prerequisite for the occurrence of a neutron halo.
Kusumoto, Tamon*; Matsuya, Yusuke; Baba, Kentaro*; Ogawara, Ryo*; Akselrod, M. S.*; Harrison, J.*; Fomenko, V.*; Kai, Takeshi; Ishikawa, Masayori*; Hasegawa, Sumitaka*; et al.
Radiation Measurements, 132, p.106256_1 - 106256_4, 2020/03
Times Cited Count:8 Percentile:58.60(Nuclear Science & Technology)Internal radiation therapy with Cu-64 concentrates energy deposition in tumor cells by virtue of released Auger electrons with low energy. In our previous study, we have attached the solutions at the surface of Fluorescent Nuclear Track Detector (FNTD) and succeeded in measuring the absorbed doses of Auger electrons registered in FNTD. However, because there are several types of radiation emitted from the source, i.e., beta rays, positron etc., the contribution degree of Auger electron to energy concentration remain uncertain. In this study, we quantitatively analyzed the spatial dose distribution in the FNTD based on Monte Carlo simulation with PHITS and GEANT4, and evaluated high dose deposited by Auger electrons. The dose distribution calculated by the PHITS code is exactly equivalent to that by Geant4. Also, the simulations are well agreement with experimental results. If the contribution of Auger electrons is ignored, the significantly high absorbed dose proximal to the source is not properly reduced. These findings demonstrate that Auger electrons work very effectively to kill cancer cells proximal to Cu-64 source while minimizing damage effects on normal cells distal to the source.
Sue, Yuki*; Yotsuzuka, Mai*; Futatsukawa, Kenta*; Hasegawa, Kazuo; Iijima, Toru*; Iinuma, Hiromi*; Inami, Kenji*; Ishida, Katsuhiko*; Kawamura, Naritoshi*; Kitamura, Ryo; et al.
Physical Review Accelerators and Beams (Internet), 23(2), p.022804_1 - 022804_7, 2020/02
Times Cited Count:2 Percentile:21.81(Physics, Nuclear)A destructive monitor to measure the longitudinal bunch width of a low-energy and low-intensity muon beam was developed. This bunch-width monitor (BWM) employed microchannel plates to detect a single muon with high time resolution. In addition, constant-fraction discriminators were adopted to suppress the time-walk effect. The time resolution was measured to be 65 ps in rms using a picosecond-pulsed laser. This resolution satisfied the requirements of the muon linac of the J-PARC E34 experiment. We measured the bunch width of negative-muonium ions accelerated with a radio-frequency quadrupole using the BWM. The bunch width was successfully measured to be 54
11 ns, which is consistent with the simulation.
Sue, Yuki*; Iijima, Toru*; Inami, Kenji*; Yotsuzuka, Mai*; Iinuma, Hiromi*; Nakazawa, Yuga*; Otani, Masashi*; Kawamura, Naritoshi*; Shimomura, Koichiro*; Futatsukawa, Kenta*; et al.
Proceedings of 16th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.55 - 60, 2019/07
The result of bunch size measurement of muon accelerated by RFQ up to 89 keV is presented in this paper. A four-stage muon linac for precise measurement of muon property is under construction in the J-PARC. The demonstration of the first muon RF acceleration with an RFQ linac was conducted and the transverse profile of the accelerated muons was measured in 2017. As one of the remaining issues for the beam diagnostic system, the longitudinal beam profile after the RFQ should be measured to match the profile to the designed acceptance of the subsequent accelerator. For this purpose, the new longitudinal beam monitor using the microchannel plate is under development. The time resolution of the monitor aims to be around 30 to 40 ps corresponding to 1% of a period of an operating frequency of the accelerator, which is 324 MHz. On November 2018, the bunch size of accelerated negative muonium ion of 89 keV with the RFQ was measured using this monitor at the J-PARC MLF. The measured bunch width is ns, which is consistent with the simulation.
Sue, Yuki*; Iijima, Toru*; Inami, Kenji*; Yotsuzuka, Mai*; Futatsukawa, Kenta*; Kawamura, Naritoshi*; Mibe, Tsutomu*; Miyake, Yasuhiro*; Otani, Masashi*; Hasegawa, Kazuo; et al.
Proceedings of 10th International Particle Accelerator Conference (IPAC '19) (Internet), p.37 - 40, 2019/06
The result of bunch size measurement of muon accelerated by RFQ up to 89 keV is presented in this paper. A four-stage muon linac for precise measurement of muon property is under construction in the J-PARC. The demonstration of the first muon RF acceleration with an RFQ linac was conducted and the transverse profile of the accelerated muons was measured in 2017. As one of the remaining issues for the beam diagnostic system, the longitudinal beam profile after the RFQ should be measured to match the profile to the designed acceptance of the subsequent accelerator. For this purpose, the new longitudinal beam monitor using the microchannel plate is under development. The time resolution of the monitor aims to be around 30 to 40 ps corresponding to 1% of a period of an operating frequency of the accelerator, which is 324 MHz. On November 2018, the bunch size of accelerated negative muonium ion of 89 keV with the RFQ was measured using this monitor at the J-PARC MLF. The measured bunch width is ns, which is consistent with the simulation.
Saga, Ryo*; Matsuya, Yusuke; Takahashi, Rei*; Hasegawa, Kazuki*; Date, Hiroyuki*; Hosokawa, Yoichiro*
Journal of Radiation Research, 60(3), p.298 - 307, 2019/05
Times Cited Count:25 Percentile:80.69(Biology)In radiotherapy, it is recognized that cancer stem cells (CSCs) in tumor tissue shows radio-resistance. However, the relationship between content percentage of the CSCs and dose-response curve on cell survival remain unclear. In this study, we developed a stochastic model considering progeny cells and stem cells, and investigated the impact of stem cells on radio-sensitivity. From the flow-cytometric analysis (cell experiments), the content percentage of stem cells was 3.2% or less which agreed well with the model estimation from the cell survival curve. Based on the verification, it is suggested that cell survival in high-dose range is largely affected by the CSCs. In addition, regarding the sub-population of stem cells, the present model well reproduces the dose response on lethal lesions to DNA comparing with the conventional LQ model. This outcome indicates that the stem cells must be considered for describing the dose-response curve in wide dose range.
Miura, Akihiko; Maruta, Tomofumi*; Liu, Y.*; Miyao, Tomoaki*; Kawane, Yusuke; Ouchi, Nobuo; Oguri, Hidetomo; Ikegami, Masanori*; Hasegawa, Kazuo
JPS Conference Proceedings (Internet), 8, p.011002_1 - 011002_6, 2015/09
In the J-PARC Linac, an energy upgrade project has started since 2009 using Annular-ring Coupled Structure cavities to achieve design beam power of 1 MW at the exit of the downstream rapid cycling synchrotron. Linac beam parameters of the upgraded Linac is drastically improved especially for the beam energy from 181 to 400 MeV in the project. To meet with the significant upgrades of the Linac, beam monitors to be used for the upgraded beam line are newly designed and fabricated as well as the beam monitor layout is designed with the consideration to the beam commissioning strategies. This paper introduces the beam monitor layout in the new beam line and the commissioning results to confirm the beam monitor functioning.
Oguri, Hidetomo; Hasegawa, Kazuo; Ito, Takashi; Chishiro, Etsuji; Hirano, Koichiro; Morishita, Takatoshi; Shinozaki, Shinichi; Ao, Hiroyuki; Okoshi, Kiyonori; Kondo, Yasuhiro; et al.
Proceedings of 11th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.389 - 393, 2014/10
no abstracts in English
Tomita, Takuro*; Nishikino, Masaharu; Hasegawa, Noboru; Minami, Yasuo*; Takei, Ryota*; Baba, Motoyoshi*; Eyama, Tsuyoshi*; Takayoshi, Shodai*; Kaihori, Takeshi*; Morita, Toshimasa; et al.
Journal of Laser Micro/Nanoengineering, 9(2), p.137 - 142, 2014/06
Times Cited Count:5 Percentile:28.31(Nanoscience & Nanotechnology)Femtosecond laser ablation processes on platinum, gold, and tungsten were observed by the single shot pump and probe reflective imaging using a soft X-ray laser probe. To avoid the timing error due to the jitter, we adopted a posteriori correction technique by simultaneous measurement of timing between the pump and probe pulses for every single shot, using a soft X-ray streak camera. A clear difference was found in the temporal behavior of the dynamical response of the soft X-ray reflectivity depending on the irradiated laser fluence in these three materials. On the other hand, the narrow dark rings were found in Pt and W, while an additional bright ring was found outside the dark disk in Au. Our result gives the experimental data comparable with various numerical simulations.
Fukushi, Keisuke*; Hasegawa, Yusuke*; Maeda, Koshi*; Aoi, Yusuke*; Tamura, Akihiro*; Arai, Shoji*; Yamamoto, Yuhei*; Aosai, Daisuke*; Mizuno, Takashi
Environmental Science & Technology, 47(22), p.12811 - 12818, 2013/11
Times Cited Count:31 Percentile:62.18(Engineering, Environmental)Eu(III) sorption on granite was examined by the combined microscopic and macroscopic approaches. Polished thin sections of the granite were reacted with solutions containing 10 M of Eu(III) and analyzed using EPMA and LA-ICP-MS. The Eu enrichment up to 6 wt.% was observed on most of the biotite grains. The Eu-enriched parts commonly lose K, which is the interlayer cation of biotite, indicating that the sorption mode is cation exchange in the interlayer. Batch Eu(III) sorption experiments on granite and biotite powders were conducted. The macroscopic sorption behavior of biotite was consistent with that of granite. The obtained sorption edges can be reproduced reasonably by the modeling considering single-site cation exchange reactions. Granite is complex mineral assemblages. However, the combined microscopic and macroscopic approaches revealed that elementary reactions by single phase can be representative for the bulk sorption reaction in complex mineral assemblages.
Shibanuma, Kiyoshi; Arai, Takashi; Hasegawa, Koichi; Hoshi, Ryo; Kamiya, Koji; Kawashima, Hisato; Kubo, Hirotaka; Masaki, Kei; Saeki, Hisashi; Sakurai, Shinji; et al.
Fusion Engineering and Design, 88(6-8), p.705 - 710, 2013/10
Times Cited Count:11 Percentile:62.29(Nuclear Science & Technology)Toyoshima, Atsushi; Haba, Hiromitsu*; Tsukada, Kazuaki; Asai, Masato; Akiyama, Kazuhiko*; Goto, Shinichi*; Ishii, Yasuo; Nishinaka, Ichiro; Sato, Tetsuya; Nagame, Yuichiro; et al.
Radiochimica Acta, 96(3), p.125 - 134, 2008/03
Times Cited Count:29 Percentile:84.99(Chemistry, Inorganic & Nuclear)Formation of an anionic fluoride-complex of element 104, rutherfordium (Rf) produced in the Cm(
O,5n)
Rf reaction was studied by an anion-exchange method based on an atom-at-a-time scale. It was found that the hexafluoro complex of Rf, [RfF
]
, was formed in the studied fluoride ion concentrations of 0.0005 - 0.013 M. Formation of [RfF
]
was significantly different from that of the homologues Zr and Hf, [ZrF
]
and [HfF
]
; the evaluated formation constant of [RfF
]
is at least one-order of magnitude smaller than those of [ZrF
]
and [HfF
]
.
Nagame, Yuichiro; Tsukada, Kazuaki; Asai, Masato; Toyoshima, Atsushi; Akiyama, Kazuhiko; Ishii, Yasuo; Sato, Tetsuya; Hirata, Masaru; Nishinaka, Ichiro; Ichikawa, Shinichi; et al.
Radiochimica Acta, 93(9-10), p.519 - 526, 2005/00
Times Cited Count:31 Percentile:87.27(Chemistry, Inorganic & Nuclear)no abstracts in English
Amamoto, Ippei; Kobayashi, Hidekazu; Ayame, Yasuo; Onishi, Takashi; Inaba, Yusuke*; Utsumi, Kazuo*; Takeshita, Kenji*; Onoe, Jun*; Koshizaka, Akiko*; Hasegawa, Yoshio*
no journal, ,
The development on synthesis of sorbent was carried out to separate the platinum group species such as Ru, Rh and Pd in high-level radioactive liquid waste. After sorption test using developed sorbents, the spherical porous silica impregnated aluminium ferrocyanide was effective to sorb the species of Ru and Pd in the nitric solution. This sorption effect remained stable when tested on actual high-level radioactive liquid waste. It was found that more treated waste could be loaded into the borosilicate glass than untreated waste.