Morishita, Yuki; Sagawa, Naoki; Fujisawa, Makoto; Kurosawa, Shunsuke*; Sasano, Makoto*; Hayashi, Masateru*; Tanaka, Hiroki*
Radiation Measurements, 181, p.107371_1 - 107371_5, 2025/02
Times Cited Count:0The effects of different types of radiation on a high-resolution alpha imager developed using an electron multiplying charge-coupled device (EMCCD) camera were investigated. This imager was originally developed to visualize alpha particles from Pu oxide particles at decommissioning sites. Other types of radiation such as beta particles, gamma rays, and neutrons are also present. The purpose of this study is to investigate the effects of these background radiations on the imager and to develop a method to discriminate between alpha particles and other types of radiation. When measuring gamma rays, and neutrons, the sensor of the EMCCD camera generated high intensity signals due to gamma rays and neutrons. These radiations were identified by image processing. The image values were binarized and the findContours function was applied to count the number of alpha particle spots. The results showed that alpha and gamma (neutron) radiation can be discriminated by using differences in intensity. This method will be useful for visualizing alpha particles at decommissioning sites.
Morishita, Yuki; Kurosawa, Shunsuke*; Yamaji, Akihiro*; Hayashi, Masateru*; Sasano, Makoto*; Makita, Taisuke*; Azuma, Tetsushi*
Scientific Reports (Internet), 11(1), p.5948_1 - 5948_11, 2021/03
Times Cited Count:4 Percentile:33.86(Multidisciplinary Sciences)The internal exposure of workers who inhale plutonium dioxide particles in nuclear facilities is a crucial matter for human protection from radiation. To determine the activity median aerodynamic diameter values at the working sites of nuclear facilities in real time, we developed a high-resolution alpha imager using a ZnS(Ag) scintillator sheet, an optical microscope, and an electron-multiplying charge-coupled device camera. Then, we designed and applied a setup to measure a plutonium dioxide particle and identify the locations of the individual alpha particles in real time. Employing a Gaussian fitting, we evaluated the average spatial resolution of the multiple alpha particles was evaluated to be 16.2 umFWHM with a zoom range of 5 x. Also, the spatial resolution for the plutonium dioxide particle was 302.7 umFWHM due to the distance between the plutonium dioxide particle and the ZnS(Ag) scintillator. The influence of beta particles was negligible, and alpha particles were discernible in the alpha-beta particle contamination. The equivalent volume diameter of the plutonium dioxide particle was calculated from the measured count rate. These results indicate that the developed alpha imager is effective in the plutonium dioxide particle measurements at the working sites of nuclear facilities for internal exposure dose evaluation.
Aizawa, Kosuke; Chikazawa, Yoshitaka; Ishikawa, Nobuyuki; Kubo, Shigenobu; Okazaki, Hitoshi*; Mito, Makoto*; Tozawa, Katsuhiro*; Hayashi, Masateru*
Proceedings of 2012 International Congress on Advances in Nuclear Power Plants (ICAPP '12) (CD-ROM), p.465 - 474, 2012/06
A conceptual design study of an advanced sodium-cooled fast reactor JSFR has progressed in the "Fast Reactor Cycle Technology Development (FaCT)" project in Japan. JSFR has two failed fuel detection systems in the core. One is a failed fuel detection (FFD) system which continuously monitors a fission product from failed fuel subassembly. The other is a failed fuel detection and location (FFDL) system which locates when it receives signals from FFD. In this study, requirements to the FFD-DN and the FFD-DN design to meet the requirements were investigated for the commercial and demonstration JSFR. For the FFDL systems, experiences in the previous fast reactors and the research and development of FFDL system for JSFR were investigated. Operation experiences of the Selector-valve FFDL system were accumulated in PFR and Phenix. Tagging-gas system experiences were accumulated in EBR-II and FFTF.
Hayashi, Masateru*; Makita, Taisuke*; Azuma, Tetsushi*; Sasano, Makoto*; Yoshida, Hiroko*; Tsuda, Shuichi
no journal, ,
Evaluation of dose rates of artificial nuclides is of importance to make a decision on return of residents to their hometown contaminated by the Fukushima Dai-ichi Nuclear Power Plant accident. This study applies an unfolding method to measured data by a NaI(Tl) detector in/outside houses, and obtained gamma-ray energy spectra. We calculated ratios of dose rate from natural nuclides such as 40K and Uran-Thorium series to those of artificial nuclides. It was found that the ratios are almost constant, given that no artificial nuclide exists. This means a possibility that dose rates of artificial nuclides can be precisely estimated by subtracting dose rates of natural nuclides.
Morishita, Yuki; Sagawa, Naoki; Fujisawa, Makoto; Kurosawa, Shunsuke*; Sasano, Makoto*; Hayashi, Masateru*; Tanaka, Hiroki*
no journal, ,
This study reports the effects of different types of radiation on a high-resolution alpha imager, developed using an Electron Multiplying Charge-Coupled Device (EMCCD) camera. The imager was originally designed to visualize Pu oxide particles in decommissioning sites, where other types of radiation such as beta particles, gamma-rays, and neutrons are also present. The measurement of alpha particles, beta particles, gamma-rays, and neutrons were performed, and it was found that the EMCCD camera's sensor detected gamma-rays and neutrons. The discrimination method was based on the characteristics of the image distribution, where the image values were binarized and a Gaussian filter was applied to count the number of alpha particle spots. The results show that it is possible to discriminate between alpha and gamma (neutron) rays using the difference in intensity. The study provides important information for the development of radiation detection techniques in decommissioning sites.
Sagawa, Naoki; Morishita, Yuki; Fujisawa, Makoto; Kurosawa, Shunsuke*; Sasano, Makoto*; Hayashi, Masateru*
no journal, ,
At nuclear facilities that handle plutonium, visualization of Pu particles in working environment is important for evaluating internal exposure doses for workers. In this study, a new type of Quantitative Complementary Metal Oxide Semiconductor (qCMOS) camera with low noise signals and high readout speed has been used in the alpha imaging system to improve the spatial resolution for alpha-rays and to visualize Pu particles. In addition, effects of irradiation on the system have been confirmed with various types of radiation. As a result, it was found that only alpha rays can be measured specifically by setting a threshold in terms of area, even if noise is generated, without the influence of beta rays, gamma rays, or neutrons.
Morishita, Yuki; Kurosawa, Shunsuke*; Yamaji, Akihiro*; Hayashi, Masateru*; Sasano, Makoto*; Makita, Taisuke*; Azuma, Tetsushi*
no journal, ,
It is crucial in considering internal exposure when workers inside nuclear facilities inhale plutonium particles. The internal exposure dose is strongly affected by the particle size distribution defined as activity median aerodynamic diameter (AMAD). To acquire the AMAD value at the working site of the nuclear facility, we developed an alpha imaging detector using an optical camera and an optical microscope. Then, we applied it for plutonium particle measurements. The ZnS(Ag) scintillator sheet and a plutonium particle were close to each other. Alpha particles were absorbed in the ZnS(Ag) scintillator and were converted to scintillation light. An Electron Multiplying (EM) CCD camera was mounted on top of the optical microscope to capture scintillation light. The zoom range was adjustable from 5x - 20x. When using the zoom range of 20 x, the resolution and Field of View were 0.81 um/pixel and 412.9 um 412.9 um, respectively. The Full width at half maximum (FWHM) of an alpha particle was evaluated to be 17.9 um. Locations of individual alpha particles from a plutonium particle can be identified in real-time. The number of alpha counts was agreed with those measured using a commercial ZnS(Ag) scintillation counter. The measured alpha counts will be able to convert to radioactivities and AMAD. Thus, the ultra-high-resolution alpha imager will be promising plutonium particle measurements at the working sites of nuclear facilities.
Morishita, Yuki; Sagawa, Naoki; Fujisawa, Makoto; Kurosawa, Shunsuke*; Sasano, Makoto*; Hayashi, Masateru*; Tanaka, Hiroki*
no journal, ,
This study reports the effects of different types of radiation on a high-resolution alpha imager, developed using an Electron Multiplying Charge-Coupled Device (EMCCD) camera. The imager was originally designed to visualize Pu oxide particles in decommissioning sites, where other types of radiation such as beta particles, gamma-rays, and neutrons are also present. The study aims to confirm the effects of these radiations on the imager and to develop a discrimination method between alpha particles and other radiations. The measurement of alpha particles, beta particles, gamma-rays, and neutrons were performed. The discrimination method was based on the characteristics of the image distribution, where the image values were binarized and a Gaussian filter was applied to count the number of alpha particle spots. The results show that it is possible to discriminate between alpha and gamma (neutron) rays using the difference in intensity. The study provides important information for the development of radiation detection techniques in decommissioning sites.
Fujisawa, Makoto; Morishita, Yuki; Sagawa, Naoki; Kurosawa, Shunsuke*; Sasano, Makoto*; Hayashi, Masateru*
no journal, ,
The measurement of alpha contamination, or alpha radiation, is important for the decommissioning of the Fukushima Daiichi Nuclear Power Station (FDNPS). It is very important to verify whether alpha particles can be visualized in a situation where alpha, beta, gamma-rays are mixed together. In this study, we applied our newly developed alpha imager to the measurement of actual samples containing a mixture of alpha, beta, and gamma nuclides, and verified its effectiveness. The alpha imager consisted of a qCMOS camera (ORCA-Quest (C15550-20UP)) and an optical microscope (BX53MRF-S from Olympus). A ZnS(Ag) scintillator with a thickness of 3.25 mg/cm was used for alpha measurements by placing the scintillator closely over a sample. An
Am alpha standard source was measured to verify whether alpha particles could be measured. In addition, samples containing a mixture of alpha, beta, and gamma nuclides were measured. Image processing was used to extract clusters of alpha particles. By applying image processing, clusters of alpha particles were successfully extracted. When measuring a sample with a mixture of alpha, beta, and gamma nuclides, clusters of alpha particles could be confirmed. Although the sample had a higher beta activity than alpha activity, only alpha particles were successfully extracted. The developed alpha imager will be useful for contamination measurement in the site of FDNPS.
Nabeshima, Kunihiko; Aizawa, Kosuke; Chikazawa, Yoshitaka; Okazaki, Hitoshi*; Hayashi, Masateru*
no journal, ,
FFD-DN (failed fuel detection system by delayed neutron monitoring) method is to measure the delayed neutron flux which is released from failed fuel to sodium coolant when fuel failure occurs. Here, the part of FFD-DN method will be cleared. Then, reactor trip before fuel failure propagation could be performed by new FFD-DN detection form with BC filter and collimator.
Yoshida, Hiroko*; Hayashi, Masateru*; Makita, Taisuke*; Azuma, Tetsushi*; Sasano, Makoto*; Tsuda, Shuichi
no journal, ,
Investigation on distribution of radioactive substances in Fukushima within former evacuation areas has been ongoing since 2012. Reduction rates of air dose rate indoor and outdoor were compared for 54 residential houses in Iidate-mura and Minami-Soma. Just after the decontamination, the averaged value of the outdoor reduction rates was higher than those indoor, while the averaged outdoor reduction rate in 2019 and 2020 was almost identical to the indoor one within uncertainties. This means that indoor air dose rate has decreased less than outdoors. One of the reasons would be the existence of additional radionuclides coming from outside of the decontamination area around the houses, according to spectra analyses of air dose measurement and deposition of radionuclides on the roof.
Kodama, Shohei*; Kurosawa, Shunsuke*; Morishita, Yuki; Usami, Hiroshi; Hayashi, Masateru*; Tanaka, Hiroki*; Yoshino, Masao*; Kamada, Kei*; Yoshikawa, Akira*; Torii, Tatsuo
no journal, ,
After Fukushima 1st Nuclear Plant accident, a large number of radioactive pollutants or nuclear debris with very high dose of more than a few Sv/h still have existed. To estimate the dose of such pollutants, a Japan Atomic Energy Agency research group has suggested a new technique to use a long optical fiber and a red-emitting scintillator, and the scintillation photons are read outside of high dose area. We tested the gamma-ray detection performance of a ruby (Cr:AlO
) and a newly developed Cs
HfI
scintillators as a scintillating probe coupled with an optical fiber in this study.