Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Masuda, Ryo; Mitsui, Takaya; Kobayashi, Yasuhiro*; Higashitaniguchi, Satoshi*; Seto, Makoto
Japanese Journal of Applied Physics, 48(12), p.120221_1 - 120221_3, 2009/12
Times Cited Count:9 Percentile:35.54(Physics, Applied)A neV-resolution spectrometer using 14.4 keV synchrotron-based Fe M
ssbauer radiation has been developed to observe the quasi-elastic scattering by condensed matter. It consists of a
Fe
O
nuclear resonant Bragg monochromator and a
Fe stainless steel nuclear analyzer. As a feasibility study, the quasi-elastic scattering by supercooled glycerol near its melting point has been observed. The instrumental function of the spectrometer was 42.2 neV. The energy broadening of 11 neV due to the quasi-elastic scattering was observed.
Seto, Makoto; Masuda, Ryo; Higashitaniguchi, Satoshi*; Kitao, Shinji*; Kobayashi, Yasuhiro*; Inaba, Chika*; Mitsui, Takaya; Yoda, Yoshitaka*
Physical Review Letters, 102(21), p.217602_1 - 217602_4, 2009/05
Times Cited Count:60 Percentile:88.03(Physics, Multidisciplinary)We have developed a new method that yields Mssbauer absorption spectra using synchrotron radiation (SR); this method is applicable for almost all M
ssbauer nuclides including those that cannot be measured by previous methods using radioisotope (RI) sources. The M
ssbauer spectrum of the 68.752 keV excited state of
Ge, which cannot be measured using a RI source, was measured using SR. Our results show that this method can be used to perform advanced M
ssbauer spectroscopy measurements owing to the excellent features of SR.
Masuda, Ryo; Mitsui, Takaya; Kitao, Shinji*; Higashitaniguchi, Satoshi*; Yoda, Yoshitaka*; Seto, Makoto
Japanese Journal of Applied Physics, 47(10), p.8087 - 8090, 2008/10
Times Cited Count:14 Percentile:48.20(Physics, Applied)A synchrotron-radiation-based neV-resolution spectrometer has been developed using single-line pure nuclear Bragg reflection. The developed optical system consists of two components: a FeBO
single crystal near the N
el temperature for producing
Fe M
ssbauer radiation from synchrotron radiation, and a single-line M
ssbauer absorber (
Fe-enriched stainless steel foil) for analyzing the energy distribution. As a feasibility study, we have performed the measurement of the M
ssbauer radiation diffracted by a Si crystal under ultrasound vibration with the optical system and have successfully observed the neV-range energy modulation due to the ultrasound vibration.
Mitsui, Takaya; Seto, Makoto; Hirao, Naohisa*; Oishi, Yasuo*; Kobayashi, Yasuhiro*; Higashitaniguchi, Satoshi*; Masuda, Ryo*
Japanese Journal of Applied Physics, Part 2, 46(16), p.L382 - L384, 2007/04
Times Cited Count:12 Percentile:43.55(Physics, Applied)Energy-domain synchrotron radiation Mssbauer spectroscopy was performed by a single-line M
ssbauer filtering technique and focusing X-ray optics. Pure nuclear Bragg reflection from a heated
FeBO
single crystal was used for a neV order bandwidth ultrahigh energy resolution X-ray analyzer. As an example of small target research, the M
ssbauer transmission spectrum of polycrystalline iron metal was observed using a diamond anvil cell at multimegabar pressures (252 GPa) for the first time.
Mitsui, Takaya; Seto, Makoto; Kikuta, Seishi*; Hirao, Naohisa*; Oishi, Yasuo*; Takei, Fumihiko*; Kobayashi, Yasuhiro*; Kitao, Shinji*; Higashitaniguchi, Satoshi*; Masuda, Ryo*
Japanese Journal of Applied Physics, Part 1, 46(2), p.821 - 825, 2007/02
Times Cited Count:34 Percentile:74.24(Physics, Applied)Ultrahigh monochromatic 14.4 keV X-rays with a narrow bandwidth of 15.4 neV were generated successfully with a high counting rate of 12,000 counts/s at the undulator beamline (BL11XU) of SPring-8. It was achieved by combining an intense X-ray from the third generation synchrotron radiation facility SPring-8 and pure nuclear Bragg scattering of a very highquality FeBO
perfect single crystal at the N
el temperature. We describe the detailed study of the beam characteristics and some performance test experiments of energy-domain synchrotron radiation M
ssbauer spectroscopy, including a highpressure experiment using a diamond anvil cel.
Imai, Yasuhiko*; Yoda, Yoshitaka*; Kitao, Shinji*; Masuda, Ryo; Higashitaniguchi, Satoshi*; Inaba, Chika*; Seto, Makoto
Advances in X-ray/EUV Optics and Components II (Proceedings of SPIE Vol.6705), p.670512_1 - 670512_7, 2007/00
We have developed a high-resolution monochromator (HRM) for the measurement of nuclear resonant scattering of synchrotron radiation by Te at 35.49 keV using the backscattering of sapphire (9 1 -10 68). The relative energy resolution of
is achieved, that is 7.5 meV in energy bandwidth. A new HRM has been desired at this energy region because of the low efficiency of usual Si HRMs. This HRM opens studies on element-specific dynamics and electronic state of substances containing
Te.
Masuda, Ryo*; Higashitaniguchi, Satoshi*; Kitao, Shinji*; Kobayashi, Yasuhiro*; Seto, Makoto*; Mitsui, Takaya; Yoda, Yoshitaka*; Haruki, Rie*; Kishimoto, Shunji*
Journal of the Physical Society of Japan, 75(9), p.094716_1 - 094716_4, 2006/09
Times Cited Count:2 Percentile:19.07(Physics, Multidisciplinary)no abstracts in English
Mitsui, Takaya; Seto, Makoto; Higashitaniguchi, Satoshi*
no journal, ,
no abstracts in English
Masuda, Ryo; Mitsui, Takaya; Kitao, Shinji*; Higashitaniguchi, Satoshi*; Yoda, Yoshitaka*; Seto, Makoto
no journal, ,
no abstracts in English