Hata, Katsuro; Suzuki, Kazuyuki; Miyoshi, Ryuta; Sugai, Eiji; Hikita, Keiichi; Nakamura, Yoshinobu; Hayashi, Shinichiro
no journal, ,
The pulse filter of the clarification process used the sintered metal powder filter at Tokai reprocessing plant. It is known that the sintered metal powder filter is easy to be clogged up by sludge. Therefore, we examined the filtration performance of the sintered laminated wire mesh filter which might substitute for the sintered metal powder filter.
Sugai, Eiji; Terunuma, Hirotaka; Otani, Takehisa; Hikita, Keiichi; Hatanaka, Akira; Samoto, Hirotaka; Okano, Masanori; Hayashi, Shinichiro
no journal, ,
A dissolution test of the sludge gathered from the dissolver of Tokai Reprocessing Plant (TRP) was performed for the purpose of eliminating of the sludge, which deposited in the dissolver and clogged pipes equipped in the dissolver. In the result, the sludge consisted primarily of ZrMoO
(OH)
(H
O)
and was possible to eliminate at the rate of about 80% by using NaOH and HNO
reagent which was commonly-used in the PUREX process. From this experimental result, it is thought that the method of using NaOH and HNO
reagent is effective method for the elimination of the sludge which deposited in the dissolver.
Kikuchi, Hideki; Suzuki, Kazuyuki; Sugai, Eiji; Hikita, Keiichi; Otani, Takehisa; Samoto, Hirotaka; Hayashi, Shinichiro
no journal, ,
About 6t the Fugen MOX type B fuels, whose Pu content rate is about 1.7%, were reprocessed on Tokai Reprosessing Plant(TRP) to the present. It was required to control plutonium(Pu) concentration of dissolution liquor because of the higher Pu content of the MOX fuels. There operational method to control Pu concentration by dilution has be established. And the amount of Pu, which was transferred to the highly radioactive liquid waste system with the residue from the clarification process, was investigated.
Suzuki, Kazuyuki; Nakamura, Yoshinobu; Hikita, Keiichi; Kogawa, Takayuki; Hayashi, Shinichiro
no journal, ,
The reprocessing plant dissolves Spent Fuels and it is a process to attract U and Pu after the removal of the Fission Products. Because dissolver is a tank with boiling nitric acid, there is it in the severe corrosion environment. Corrosion environment of the heat transfer surface is the severest. Therefore, the dissolver is made in High Chrome Nickel Steel in consideration of corrosion resistance. This paper reports a supersonic wave measurement method and corrosion rate of the dissolver.
Hikita, Keiichi; Uchida, Naoki; Suzuki, Kazuyuki; Mitani, Hironobu; Hata, Katsuro; Hayashi, Shinichiro; Yudo, Mitsuhiro*; Sakai, Hideaki*
no journal, ,
TRP dissolver deposits dissolver sludge which consists of zircaloy swarf with shearing operation and undissolved fission products such as Mo, Ru, Rh and Pd with dissolution operation. We have developed dissolver cleaning device which can be introduced through a ventilation pipe to inside dissolver.