A Cause and the measures that the expansion joint of the steam plumbing for Reprocessing Plants damaged

Nishino, Shohei; Nishida, Tetsuro; Kawasaki, Ichio; Motohashi, Masahiro; Kambara, Takashi*; Suzuki, Takaichi*; Kinoshita, Masato*

Nihon Hozen Gakkai Dai-20-Kai Gakujutsu Koenkai Yoshishu, p.14 - 21, 2024/08

Steam is used to a process and air conditioning in Nuclear fuel Cycle engineering Laboratories (NCL). The steam is used mainly in Reprocessing Plant, and it is supplied by two steam plumbing. A leak occurred from the steam plumbing in November, 2022. As a result of cause investigation, I estimated that it had leaked by a water hammer caused for the trouble of the steam trap.

Journal Articles

High-temperature test for BGaN semiconductor neutron detectors

Okita, Shoichiro; Sakurai, Tatsuhiro*; Kudo, Ryohei*; Takagi, Katsuyuki*; Nakano, Takayuki*; Hino, Masahiro*

KURNS Progress Report 2023, P. 97, 2024/07

Journal Articles

The Maintenance management of thickness measurement on the water tube boiler

Nishino, Shohei; Motohashi, Masahiro; Nishida, Tetsuro; Kawasaki, Ichio

Nihon Hozen Gakkai Dai-19-Kai Gakujutsu Koenkai Yoshishu, p.73 - 79, 2023/08

There are 4-boiler in Nuclear fuel Cycle engineering Laboratories (NCL). These boilers have been operated in the long term over 29 years. There are many water tube as one of many identical components which together make up a boilers. The leakage from water tube have occurred four times in recently. It was presumed that sulfur acid corrosion had caused the leakage. Therefore, to reduce generation of sulfuric acid corrosion, the operation term was changed to long, and regular inspection (non-destructive testing) have been carried out.

Journal Articles

Neutron reflectometry-based ${it in situ}$ structural analysis of an aligning agent additive for the alignment of nematic liquid crystals on solid substrates

Nemoto, Fumiya*; Yamada, Norifumi*; Hino, Masahiro*; Aoki, Hiroyuki; Seto, Hideki*

Soft Matter, 18(3), p.545 - 553, 2022/01

 Times Cited Count:2 Percentile:13.57(Chemistry, Physical)

Journal Articles

Development of the multi-cubic $$gamma$$-ray spectrometer and its performance under intense $$^{137}$$Cs and $$^{60}$$Co radiation fields

Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*

Nuclear Instruments and Methods in Physics Research A, 1010, p.165544_1 - 165544_9, 2021/09

 Times Cited Count:0 Percentile:0.00(Instruments & Instrumentation)

The number of nuclear facilities being decommissioned has been increasing worldwide, in particular following the accident of the Tokyo Electric Power Company Holdings' Fukushima Daiichi Nuclear Power Station in 2011. In these nuclear facilities, proper management of radioactive materials is required. Then, A $$gamma$$-ray spectrometer with four segmentations using small volume CeBr$$_{3}$$ scintillators with a dimension of $$5 times 5 times 5$$ $$rm{mm}^3$$ was developed. The four scintillators were coupled to a multi-anode photomultiplier tube specific to intense radiation fields. We performed the $$gamma$$-ray exposure study under $$^{137}$$Cs and $$^{60}$$Co radiation fields. Under the $$^{137}$$Cs radiation field, the relative energy resolution at 1375 mSv/h was the relative energy resolution at 1375 mSv/h was 9.2$$pm$$0.05%, 8.0$$pm$$0.08%, 8.0$$pm$$0.03%, and 9.0$$pm$$0.04% for the four channels, respectively.

Journal Articles

Commissioning of Versatile Compact Neutron Diffractometer (VCND) at the B-3 beam port of Kyoto University Research Reactor (KUR)

Mori, Kazuhiro*; Okumura, Ryo*; Yoshino, Hirofumi*; Kanayama, Masaya*; Sato, Setsuo*; Oba, Yojiro; Iwase, Kenji*; Hiraka, Haruhiro*; Hino, Masahiro*; Sano, Tadafumi*; et al.

JPS Conference Proceedings (Internet), 33, p.011093_1 - 011093_6, 2021/03

no abstracts in English

Journal Articles

Effect of grain boundary on the friction coefficient of pure Fe under the oil lubrication

Adachi, Nozomu*; Matsuo, Yasutaka*; Todaka, Yoshikazu*; Fujimoto, Mikiya*; Hino, Masahiro*; Mitsuhara, Masatoshi*; Oba, Yojiro; Shiihara, Yoshinori*; Umeno, Yoshitaka*; Nishida, Minoru*

Tribology International, 155, p.106781_1 - 106781_9, 2021/03

 Times Cited Count:11 Percentile:65.79(Engineering, Mechanical)

Journal Articles

Gamma-ray spectroscopy with a CeBr$$_3$$ scintillator under intense $$gamma$$-ray fields for nuclear decommissioning

Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*; et al.

Nuclear Instruments and Methods in Physics Research A, 988, p.164900_1 - 164900_8, 2021/02

 Times Cited Count:11 Percentile:83.42(Instruments & Instrumentation)

An increasing number of nuclear facilities have been decommissioned worldwide following the 2011 accident of the TEPCO' Fukushima Daiichi Nuclear Power Station. During the decommissioning, radioactive materials have to be retrieved under proper management. In this study, a small cubic CeBr$$_3$$ spectrometer with dimensions of 5 mm $$times$$ 5 mm $$times$$ 5 mm was manufactured to perform $$gamma$$-ray spectroscopy under intense $$gamma$$-ray fields. Furthermore, thanks to a fast digital process unit and a customized photomultiplier, the device could perform $$gamma$$-ray spectroscopy at dose rates of over 1 Sv/h. The energy resolution (FWHM) at 662 keV ranged from 4.4% at 22 mSv/h to 5.2% at 1407 mSv/h for a $$^{137}$$Cs radiation field. Correspondingly, at 1333 keV, it ranged from 3.1% at 26 mSv/h to 4.2% at 2221 mSv/h for a $$^{60}$$Co radiation field, which suggested to realize $$gamma$$-ray assessment of $$^{134}$$Cs, $$^{137}$$Cs, $$^{60}$$Co, and $$^{154}$$Eu at dose rates of over 1 Sv/h.

Journal Articles

Development and application of a $$^3$$He neutron spin filter at J-PARC

Okudaira, Takuya; Oku, Takayuki; Ino, Takashi*; Hayashida, Hirotoshi*; Kira, Hiroshi*; Sakai, Kenji; Hiroi, Kosuke; Takahashi, Shingo*; Aizawa, Kazuya; Endo, Hitoshi*; et al.

Nuclear Instruments and Methods in Physics Research A, 977, p.164301_1 - 164301_8, 2020/10

 Times Cited Count:18 Percentile:89.70(Instruments & Instrumentation)

Journal Articles

Nanostructural characterization of oleyl acid phosphate in poly-$$alpha$$-olefin using small-angle X-ray scattering

Oba, Yojiro; Motokawa, Ryuhei; Hino, Masahiro*; Adachi, Nozomu*; Todaka, Yoshikazu*; Inoue, Rintaro*; Sugiyama, Masaaki*

Chemistry Letters, 49(7), p.823 - 825, 2020/07

 Times Cited Count:0 Percentile:0.00(Chemistry, Multidisciplinary)

Journal Articles

Development of blue diode laser for additive manufacturing

Higashino, Ritsuko*; Sato, Yuji*; Masuno, Shinichiro*; Shobu, Takahisa; Funada, Yoshinori*; Abe, Nobuyuki*; Tsukamoto, Masahiro*

Laser 3D Manufacturing VII (Proceedings of SPIE Vol.11271), p.1127114_1 - 1127114_7, 2020/05

 Times Cited Count:6 Percentile:95.47(Engineering, Manufacturing)

Journal Articles

Measurement of the angular distribution of $$gamma$$-rays after neutron capture by $$^{139}$$La for a T-violation search

Okudaira, Takuya; Shimizu, Hirohiko*; Kitaguchi, Masaaki*; Hirota, Katsuya*; Haddock, C. C.*; Ito, Ikuya*; Yamamoto, Tomoki*; Endo, Shunsuke*; Ishizaki, Kohei*; Sato, Takumi*; et al.

EPJ Web of Conferences, 219, p.09001_1 - 09001_6, 2019/12

Parity violating effects enhanced by up to 10$$^6$$ times have been observed in several neutron induced compound nuclei. There is a theoretical prediction that time reversal (T) violating effects can also be enhanced in these nuclei implying that T-violation can be searched for by making very sensitive measurements. However, the enhancement factor has not yet been measured in all nuclei. The angular distribution of the (n,$$gamma$$) reaction was measured with $$^{139}$$La by using a germanium detector assembly at J-PARC, and the enhancement factor was obtained. From the result, the measurement time to achieve the most sensitive T-violation search was estimated as 1.4 days, and a 40% polarized $$^{139}$$La target and a 70% polarized $$^3$$He spin filter whose thickness is 70 atm$$cdot$$cm are needed. Therefore high quality $$^3$$He spin filter is developed in JAEA. The measurement result of the (n,$$gamma$$) reaction at J-PARC and the development status of the $$^3$$He spin filter will be presented.

Journal Articles

Preheat effect on titanium plate fabricated by sputter-free selective laser melting in vacuum

Sato, Yuji*; Tsukamoto, Masahiro*; Shobu, Takahisa; Yamashita, Yoshihiro*; Yamagata, Shuto*; Nishi, Takaya*; Higashino, Ritsuko*; Okubo, Tomomasa*; Nakano, Hitoshi*; Abe, Nobuyuki*

Applied Physics A, 124(4), p.288_1 - 288_6, 2018/04

 Times Cited Count:18 Percentile:62.72(Materials Science, Multidisciplinary)

The dynamics of titanium (Ti) melted by laser irradiation was investigated in a synchrotron radiation experiment. As an indicator of wettability, the contact angle between a selective laser melting (SLM) baseplate and the molten Ti was measured by synchrotron X-rays at 30 keV during laser irradiation. As the baseplate temperature increased, the contact angle decreased, down to 28 degrees at a baseplate temperature of 500$$^{circ}$$C. Based on this result, the influence of wettability of a Ti plate fabricated by SLM in a vacuum was investigated. It was revealed that the improvement of wettability by preheating suppressed sputtering generation, and a surface having a small surface roughness was fabricated by SLM in a vacuum.

Journal Articles

Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex, 2; Neutron scattering instruments

Nakajima, Kenji; Kawakita, Yukinobu; Ito, Shinichi*; Abe, Jun*; Aizawa, Kazuya; Aoki, Hiroyuki; Endo, Hitoshi*; Fujita, Masaki*; Funakoshi, Kenichi*; Gong, W.*; et al.

Quantum Beam Science (Internet), 1(3), p.9_1 - 9_59, 2017/12

The neutron instruments suite, installed at the spallation neutron source of the Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex (J-PARC), is reviewed. MLF has 23 neutron beam ports and 21 instruments are in operation for user programs or are under commissioning. A unique and challenging instrumental suite in MLF has been realized via combination of a high-performance neutron source, optimized for neutron scattering, and unique instruments using cutting-edge technologies. All instruments are/will serve in world-leading investigations in a broad range of fields, from fundamental physics to industrial applications. In this review, overviews, characteristic features, and typical applications of the individual instruments are mentioned.

JAEA Reports

Case studies of radiation dose assessment in emergency situation of nuclear facilities

Kawasaki, Masatsugu; Nakajima, Junya; Yoshida, Keisuke; Kato, Saori; Nishino, Sho; Nozaki, Teo; Nakagawa, Masahiro; Tsunoda, Junichi; Sugaya, Yuki; Hasegawa, Rie; et al.

JAEA-Data/Code 2017-004, 57 Pages, 2017/03

JAEA-Data-Code-2017-004.pdf:2.34MB

In emergency situation of nuclear facilities, we need to estimate the radiation dose due to radiation and radioactivity to grasp the influence range of the accident in the early stage. Therefore, we prepare the case studies of dose assessment for public exposure dose and personal exposure dose and contribute them to emergency procedures. This document covers about accidents of nuclear facilities in Nuclear Science Research Institute and past accident of nuclear power plant, and it can be used for inheritance of techniques of emergency dose assessment.

Journal Articles

Neutron reflectometer

Takeda, Masayasu; Yamazaki, Dai; Hino, Masahiro*

Hamon, 24(3), p.200 - 205, 2014/08

no abstracts in English

Journal Articles

Development of two-dimensional multiwire-type neutron detector system with individual line readout and optical signal transmission

To, Kentaro; Nakamura, Tatsuya; Sakasai, Kaoru; Soyama, Kazuhiko; Hino, Masahiro*; Kitaguchi, Masaaki*; Yamagishi, Hideshi*

Nuclear Instruments and Methods in Physics Research A, 726, p.169 - 174, 2013/10

 Times Cited Count:9 Percentile:56.12(Instruments & Instrumentation)

A multiwire-type two-dimensional neutron detector system with a sensitive area of 128 $$times$$ 128 mm$$^{2}$$ is developed for use in the Materials and Life Science Experimental Facility at the Japan Proton Accelerator Research Complex. The system can achieve a short response time and high spatial resolution using the individual line readout method. Optical devices have been incorporated in the system for long-distance signal transmission and insulation between a detector head in the neutron shielding and signal processing circuits in the data acquisition room. The detector system exhibits a pulse-pair resolution of 1 $$mu$$s, an average spatial resolution of less than 2 mm full width at half-maximum in the sensitive region, and a two-dimensional homogeneity of 8.3% in all pixels.

Journal Articles

Investigation of advanced divertor magnetic configuration for DEMO tokamak reactor

Asakura, Nobuyuki; Shinya, Kichiro*; Tobita, Kenji; Hoshino, Kazuo; Shimizu, Katsuhiro; Uto, Hiroyasu; Someya, Yoji; Nakamura, Makoto; Ono, Noriyasu*; Kobayashi, Masahiro*; et al.

Fusion Science and Technology, 63(1T), p.70 - 75, 2013/05

no abstracts in English

Journal Articles

Investigation of advanced divertor magnetic configuration for Demo tokamak reactor

Asakura, Nobuyuki; Shinya, Kichiro*; Tobita, Kenji; Hoshino, Kazuo; Shimizu, Katsuhiro; Uto, Hiroyasu; Someya, Yoji; Nakamura, Makoto; Ono, Noriyasu*; Kobayashi, Masahiro*; et al.

Fusion Science and Technology, 63(1T), p.70 - 75, 2013/05

 Times Cited Count:14 Percentile:70.64(Nuclear Science & Technology)

Design study of poloidal field coil (PFC) locations and current distribution for the advanced divertor in the Demo tokamak reactor was presented. Concept of the super-X divertor (SXD) for Demo reactor has an outer divertor leg longer than the conventional divertor, and it extends outboard to increase both the target wetted area and connection length to the outer target ($$L_{//}$$). Equilibrium calculation code, TOSCA, was developed by introducing two parameters, i.e. super-X null radius ($$R_{SX}$$) and a ratio of the poloidal flux at the super-X null to that at the separatrix ($$f_{SX}$$). Some SXD magnetic configurations with minimal number of PFCs located outside toroidal field coil (TFC) were Demonstrated. Locations of the divertor target were also investigated. It was found that the flux expansion can be increased up to 4-10 depending on the target location and $$f_{SX}$$, and that SXD has an advantage to increase $$L_{//}$$ with $$f_{SX}$$. Thus, the divertor plasma temperature is expected to decrease at the same upstream plasma density. On the other hand, large currents for the divertor PFCs were necessary. Other arrangements of PFCs such as (1) larger $$R_{SX}$$ and (2) inside TFC, can reduce the PFC currents.

Journal Articles

Progress of high-power and long-pulse ECRF system development in JT-60

Kobayashi, Takayuki; Isayama, Akihiko; Yokokura, Kenji; Shimono, Mitsugu; Hasegawa, Koichi; Sawahata, Masayuki; Suzuki, Sadaaki; Terakado, Masayuki; Hiranai, Shinichi; Sato, Fumiaki; et al.

Nuclear Fusion, 51(10), p.103037_1 - 103037_10, 2011/10

 Times Cited Count:19 Percentile:61.36(Physics, Fluids & Plasmas)

A new gyrotron operation technique to increase oscillation efficiency was developed on the JT 60 ECRF system. The electron pitch factor was optimized by controlling anode voltage within 0.1 s after the start of the operation. By applying this technique, the gyrotron output power of 1.5 MW for 4 s was recorded, for the first time. The reduced collector heat load at 1.5 MW operations was reduced by 20% and it will be acceptable for longer pulse operation. A new gyrotron with an improved mode converter was developed in order to demonstrate reduction of the stray radiation which had limited the pulse length. The stray radiation was reduced to 1/3 of that of the original gyrotron. A conditioning operation of the improved gyrotron is proceeding up to 31 s at 1 MW. These progresses significantly contribute to enhancing the high power and long pulse capability of the ECRF system toward JT 60SA.

126 (Records 1-20 displayed on this page)