Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Sato, Kenichiro; Hiroki, Seiji; Lee, S.*; Hayashi, Naoki; Yamamoto, Kazami; Hiramatsu, Shigenori*; Toyama, Takeshi*; Arakawa, Dai*; Igarashi, Zenei*; Saeki, Riuji
Proceedings of 4th Annual Meeting of Particle Accelerator Society of Japan and 32nd Linear Accelerator Meeting in Japan (CD-ROM), p.297 - 299, 2007/00
At the injection and H0 dump line of J-PARC RCS, different beam monitors have been installed. Main purpose of the beam monitors in the injection line is to generate a beam position and profile to adjust the injection trajectory to the RCS ring. To guide the injected beam precisely is, needless to say, required to reduce the beam loss in the ring. Hence the monitor system is one of the most essential to operate the RCS. At the injection point, there are also some beams that are not match the RCS ring, that is negative and neutral proton beam. H0 dump accepts the unsuitable beams through the H0 dump line. The power limitation of the H0 dump is 4 kW. The monitor system in the dump line is to handle the beam and to monitor the dumped beam power. At the conference these monitor systems will be outlined.
Tomisawa, Tetsuo; Kishiro, Junichi; Hiroki, Fumio; Sato, Susumu; Igarashi, Zenei*; Lee, S.*; Nigorikawa, Kazuyuki*; Toyama, Takeshi*
Proceedings of 1st Annual Meeting of Particle Accelerator Society of Japan and 29th Linear Accelerator Meeting in Japan, p.165 - 167, 2004/08
It proceeds with the beam monitor production of the beam diagnosis system with J-PARC. In this paper, the present status of beam position monitors (BPM) for the SDTL is described. The impedance of strip line monitor have been adjusted in the construction of housing and electrodes of the BPM. The 4-stripline BPM has already been examined in the medium energy beam transport (MEBT) line. Preliminary results of beam position measurement for various beam conditions are reported.
Sato, Susumu; Tomisawa, Tetsuo; Hiroki, Fumio; Lee, S.*; Igarashi, Zenei*; Ikegami, Masanori*; Ueno, Akira; Kondo, Yasuhiro; Hasegawa, Kazuo; Toyama, Takeshi*; et al.
Proceedings of 1st Annual Meeting of Particle Accelerator Society of Japan and 29th Linear Accelerator Meeting in Japan, p.467 - 469, 2004/08
As a joint project of KEK and JAERI, a MW class of high intensity proton accelerator (J-PARC), consisting of Linac, 3 GeV-RCS, 50 GeV-MR, is under construction. For this accelerator, it is required to minimize the beam loss (typically, lower than0.11 W/m at the linac). To achieve the requirement, beam trajectory needs to be controlled with accuracy of some 100
m. The first stage of the acceleration (up to 181 MeV during the first stage of construction) is done by linac. The beam position monitor (BPM) in the linac utilizes 4 stripline pickups (50 ohm) on the beam transportation chamber. In this paper, systematic calibration of the BPM is described.
Sato, Susumu; Igarashi, Zenei*; Lee, S.*; Tomisawa, Tetsuo; Hiroki, Fumio; Kishiro, Junichi; Ikegami, Masanori*; Kondo, Yasuhiro; Hasegawa, Kazuo; Ueno, Akira; et al.
Proceedings of 22nd International Linear Accelerator Conference (LINAC 2004), p.429 - 431, 2004/00
As a joint project of KEK and JAERI, a MW class of high intensity proton accelerator (J-PARC), consisting of Linac, 3 GeV-RCS, 50 GeV-MR, is under construction at Tokai, Japan. For this accelerator, it is required to minimize the beam loss (typically, lower than 0.11 W/m at the linac). To achieve the requirement, beam trajectory needs to be controlled with accuracy of some 100 micro-meter. The first stage of the acceleration (up to 181 MeV during the first stage of construction) is done by linac. The beam position monitor (BPM) in the linac utilizes 4 strip-line pickups (50 ohm) on the beam transportation chamber. In this paper, systematic calibration of the BPM is described.
Tomisawa, Tetsuo; Kishiro, Junichi; Igarashi, Zenei*; Lee, S.*; Hiroki, Fumio
Proceedings of 28th Linear Accelerator Meeting in Japan, p.428 - 430, 2003/08
It is an important factor whether to have a beam loss held how, and the part of the beam diagnosis is important with the accurate beam transport, the occurrence of the high quality beam to accelerate a high intensity proton beam to handle with J-PARC linac accelerator safely. It responds to the purpose, and the beam monitor used for this beam diagnosis has it variously. There are an electric current monitor, a phase monitor, a beam position monitor, a profile monitor, a beam size monitor, a screen monitor, a beam loss monitor, and so on. Report it about these beam monitors in the present condition.
Kawabata, Kuniaki; Ogane, Katsuji*; Sato, Noritaka*; Yamada, Taichi; Abe, Hiroyuki*; Igarashi, Hiroki*
no journal, ,
no abstracts in English
Kawabata, Kuniaki; Ogane, Katsuji*; Sato, Noritaka*; Yamada, Taichi; Abe, Hiroyuki*; Igarashi, Hiroki*
no journal, ,
no abstracts in English
Kori, Shunsuke*; Igarashi, Taichi*; Okazaki, Ryuji*; Taniguchi, Hiroki*; Tanisaki, Ichiro*; Yasui, Yukio*; Igawa, Naoki; Hoshikawa, Akinori*; Ishigaki, Toru*
no journal, ,
The neutron powder diffraction for the multiferroic material, NdCrTiO has been carried out to investigate the development of the magnetic order in the material. We found the intensities of magnetic peaks increased with decreasing temperature below the transition temperature T
. We discuss temperate dependence of magnetic moments and the development of magnetic order.