Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Naruo, Yoshihiro*; Kobayashi, Hiroaki*; Nonaka, Satoshi*; Inatani, Yoshifumi*
IOP Conference Series; Materials Science and Engineering, 101, p.012177_1 - 012177_8, 2015/12
Times Cited Count:0 Percentile:0.00(Thermodynamics)Transient heat transfers from PtCo wire heaters inserted into vertically-mounted pipes, through which forced flow subcooled liquid hydrogen was passed, were measured by increasing the exponential heat input with various time periods at a pressure of 0.7 MPa and inlet temperature of 21 K. The flow velocities ranged from 0.3 to 7 m/s. The PtCo wire heaters had a diameter of 1.2 mm and lengths of 60 mm, 120 mm and 200 mm and were inserted into the pipes with diameters of 5.7mm, 8.0 mm, and 5.0 mm, respectively. With increase in the heat flux to the onset of nucleate boiling, surface temperature increased along the curve predicted by the Dittus-Boelter correlation for longer period, where it can be almost regarded as steady-state. For shorter period, the heat transfer became higher than the Dittus-Boelter correlation. In nucleate boiling regime, the heat flux steeply increased to the transient critical heat flux (CHF), which became higher for shorter period. Effect of flow velocity, period, and heated geometry on the transient CHF was clarified.
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Naruo, Yoshihiro*; Kobayashi, Hiroaki*; Inatani, Yoshifumi*
Journal of Physics; Conference Series, 507(2), p.022042_1 - 022042_4, 2014/05
Times Cited Count:2 Percentile:65.72(Engineering, Electrical & Electronic)An experimental system has been developed to investigate electro-magnetic properties of high-Tc superconductors cooled by liquid hydrogen under the external magnetic field of up to 7 T. A LH cryostat with a LH
inventory of 61 L is concentrically mounted on the inside of a LHe cryostat to cool a NbTi superconducting magnet. The experimental system is installed in an explosion-proof room and explosion proof electrical devices are used. The current leads are covered with an enclosure filled with nitrogen gas. A remote control system has been developed to maintain safety distance. Furthermore, the effects of stray magnetic field on the existing and the new devices are investigated and electro-magnetic shielding panels and enclosure made of iron were designed using ANSYS analysis. It is confirmed through the cryogenic test that the experimental system meets the design requirements.
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Hata, Koichi*; Naruo, Yoshihiro*; Kobayashi, Hiroaki*; Inatani, Yoshifumi*
AIP Conference Proceedings 1573, p.44 - 51, 2014/01
Times Cited Count:16 Percentile:98.12(Thermodynamics)Heat transfers from the inner side of vertically-mounted heated pipes to forced flow of saturated liquid hydrogen were measured with a quasi-steady increase of a heat generation rate for wide ranges of flow rate and saturated pressure. The tube heaters have lengths L of 100 mm and 167 mm with the diameter D of 4 mm and lengths of 150 mm and 250 mm with the diameter of 6 mm. The heat fluxes at departure from nucleate boiling (DNB) were higher for higher flow velocity, lower pressures and shorter L/D. The effect of L/D on the DNB heat flux was clarified. It is confirmed that our DNB correlation can describe the experimental data.
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Hata, Koichi*; Naruo, Yoshihiro*; Kobayashi, Hiroaki*; Inatani, Yoshifumi*; Narita, Norihiko*
Proceedings of 24th International Cryogenic Engineering Conference (ICEC 24) and International Cryogenic Materials Conference 2012 (ICMC 2012) (CD-ROM), p.157 - 160, 2012/05
The heat transfer in a forced flow of saturated liquid hydrogen was measured using vertically-mounted heated pipes with an inner diameter d of 6.0 mm and lengths L of 50, 100, 200 and 250 mm for wide ranges of flow velocity and pressure. The heat fluxes at departure from nucleate boiling were higher for higher flow velocities, lower pressures and shorter L. The effect of L on the DNB heat flux was clarified and could be described by the modified authors' DNB correlation.
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Hata, Koichi*; Kobayashi, Hiroaki*; Naruo, Yoshihiro*; Inatani, Yoshifumi*; Kato, Takashi; Futakawa, Masatoshi; Kinoshita, Katsuhiro*
Journal of Physics; Conference Series, 234, p.032056_1 - 032056_9, 2010/07
Times Cited Count:21 Percentile:97.57(Physics, Multidisciplinary)A thermal-hydraulics experimental system of liquid hydrogen was developed in order to investigate the forced flow heat transfer characteristics in the various cooling channels for wide ranges of subcoolings, flow velocities, and pressures up to supercritical. Forced flow through the channel is produced by adjusting the pressure difference between the tanks and the valve opening. The mass flow rate is measured from the weight change of the main tank. For the explosion protection, electrical equipments are covered with a nitrogen gas blanket layer and a remote control system has been established. The first cryogenic performance tests have confirmed that the experimental system has satisfied with the required performances. The forced convection heat transfer characteristics have been successfully measured at the pressure of 0.7 MPa for various flow velocities.
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Hata, Koichi*; Kobayashi, Hiroaki*; Naruo, Yoshihiro*; Inatani, Yoshifumi*; Kato, Takashi; Futakawa, Masatoshi; Kinoshita, Katsuhiro*
Proceedings of International Cryogenic Engineering Conference 23 (ICEC-23) and International Cryogenic Materials Conference 2010 (ICMC 2010), p.491 - 496, 2010/07
Forced flow heat transfers of liquid hydrogen through a vertical tube with the diameter, d, of 3.0 mm were measured at the pressure of 0.7 MPa for various inlet temperatures and flow velocities. The non-boiling heat transfer coefficients agreed with those by the Dittus-Boelter correlation. The heat fluxes at the inception of boiling and the departure from nucleate boiling (DNB) heat fluxes were higher for higher flow velocity and subcooling. The DNB heat fluxes were higher for larger diameter, compared with those for = 6.0 mm. The effect of tube diameter and subcooling on the DNB heat flux was clarified.
Tatsumoto, Hideki; Shirai, Yasuyuki*; Hikawa, Kyosuke*; Hara, Yuki*; Shiotsu, Masahiro*; Kobayashi, Hiroaki*; Naruo, Yoshihiro*; Yagishita, Tsuyoshi*; Nonaka, Satoshi*; Maru, Yusuke*; et al.
no journal, ,
no abstracts in English
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Horie, Yuki*; Yoneda, Kazuya*; Matsuzawa, Takayuki*; Kobayashi, Hiroaki*; Naruo, Yoshihiro*; Inatani, Yoshifumi*
no journal, ,
no abstracts in English
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Naruo, Yoshihiro*; Kobayashi, Hiroaki*; Inatani, Yoshifumi*
no journal, ,
no abstracts in English
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Hata, Koichi*; Naruo, Yoshihiro*; Kobayashi, Hiroaki*; Inatani, Yoshifumi*
no journal, ,
no abstracts in English
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Horie, Yuki*; Yoneda, Kazuya*; Matsuzawa, Takayuki*; Kobayashi, Hiroaki*; Naruo, Yoshihiro*; Inatani, Yoshifumi*
no journal, ,
no abstracts in English
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Horie, Yuki*; Yoneda, Kazuya*; Matsuzawa, Takayuki*; Kobayashi, Hiroaki*; Naruo, Yoshihiro*; Inatani, Yoshifumi*; Shigeta, Hiroki*; et al.
no journal, ,
no abstracts in English
Tatsumoto, Hideki; Shirai, Yasuyuki*; Shiotsu, Masahiro*; Kobayashi, Hiroaki*; Naruo, Yoshihiro*; Inatani, Yoshifumi*; Hata, Koichi*
no journal, ,
no abstracts in English
Tatsumoto, Hideki; Shiotsu, Masahiro*; Kobayashi, Hiroto*; Yoshikawa, Kotaro*; Shirai, Yasuyuki*; Hata, Koichi*; Kobayashi, Hiroaki*; Naruo, Yoshihiro*; Inatani, Yoshifumi*
no journal, ,
no abstracts in English