Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Nakahara, Masaumi; Watanabe, So; Takeuchi, Masayuki; Yuyama, Takahiro*; Ishizaka, Tomohisa*; Ishii, Yasuyuki*; Yamagata, Ryohei*; Yamada, Naoto*; Koka, Masashi*; Kada, Wataru*; et al.
Nuclear Instruments and Methods in Physics Research B, 542, p.144 - 150, 2023/09
Times Cited Count:0 Percentile:0.02(Instruments & Instrumentation)The structures of Eu complexes in the adsorbents prepared with various extractants were evaluated by ion beam induced luminescence analysis in an extraction chromatography for minor actinides recovery. The luminescence of Eu was measured with a proton beam obtained from the single-ended accelerator and an argon ion beam obtained from the azimuthally varying field cyclotron in Takasaki Ion Accelerators for Advanced Radiation Application in National Institutes for Quantum Science and Technology. In this study, it was confirmed that the spectral shape of Eu complexes in the adsorbents varied depending on the kinds of extractants, and the correlation between the change in the spectra and the structures of Eu complexes was investigated.
Nakahara, Masaumi; Watanabe, So; Ishii, Yasuyuki*; Yamagata, Ryohei*; Yamada, Naoto*; Koka, Masashi*; Yuyama, Takahiro*; Ishizaka, Tomohisa*; Kada, Wataru*; Hagura, Naoto*
QST-M-39; QST Takasaki Annual Report 2021, P. 62, 2023/02
In an extraction chromatography method for minor actinides recovery, analysis for the structure of complex in a silica-based adsorbent has been studied to separate minor actinides efficiently. In this study, Eu was used as simulated material of minor actinides, and silica-based adsorbents containing Eu complex were prepared. The ion beam induced luminescence spectra of Eu complexes in silica-based adsorbents were measured, and the basic data for the structures of Eu complexes were obtained.
Meigo, Shinichiro; Nakano, Keita; Okubo, Nariaki; Yuyama, Takahiro*; Ishii, Yasuyuki*
Proceedings of 18th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.296 - 301, 2021/10
no abstracts in English
Sakai, Takuro; Iikura, Hiroshi; Yamada, Naoto*; Sato, Takahiro*; Ishii, Yasuyuki*; Uchida, Masaya*
QST-M-8; QST Takasaki Annual Report 2016, P. 140, 2018/03
Koka, Masashi; Ishii, Yasuyuki; Yamada, Naoto; Okubo, Takeru; Kada, Wataru*; Kitamura, Akane; Iwata, Yoshihiro*; Kamiya, Tomihiro; Sato, Takahiro
JAEA-Technology 2016-006, 41 Pages, 2016/03
A MeV-class light ion microbeam system has been developed for micro-analysis and micro-fabrication with high spatial resolution at 3-MV single-ended accelerator in Takasaki Ion Accelerators for Advanced Radiation Application of Takasaki Advanced Radiation Research Institute, Sector of Nuclear Science Research, Japan Atomic Energy Agency. This report describes the technical improvements for the main apparatus (the accelerator, beam-transport lines, and microbeam system), and auxiliary equipments/ parts for ion beam applications such as Particle Induced X-ray/Gamma-ray Emission (PIXE/PIGE) analysis, 3-D element distribution analysis using PIXE-Computed Tomography(CT), Ion Beam-Induced Luminescence (IBIL) analysis, and Proton Beam Writing with the microbeam scanning, with functional outline of these apparatus and equipments/parts.
Sato, Takahiro; Yokoyama, Akihito; Kitamura, Akane; Okubo, Takeru; Ishii, Yasuyuki; Takahatake, Yoko; Watanabe, So; Koma, Yoshikazu; Kada, Wataru*
Nuclear Instruments and Methods in Physics Research B, 371, p.419 - 423, 2016/03
Times Cited Count:7 Percentile:55.03(Instruments & Instrumentation)Usui, Aya; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; Hashizume, Masashi*; et al.
Dai-28-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.117 - 119, 2015/12
no abstracts in English
Yuyama, Takahiro; Ishibori, Ikuo; Kurashima, Satoshi; Yoshida, Kenichi; Ishizaka, Tomohisa; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Usui, Aya; Miyawaki, Nobumasa; et al.
Proceedings of 12th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.302 - 304, 2015/09
no abstracts in English
Ishii, Yasuyuki; Okubo, Takeru; Kamiya, Tomihiro; Saito, Yuichi
Nuclear Instruments and Methods in Physics Research B, 348, p.79 - 82, 2015/04
Times Cited Count:2 Percentile:17.57(Instruments & Instrumentation)Kada, Wataru*; Miura, Kenta*; Kato, Hijiri*; Saruya, Ryota*; Kubota, Atsushi*; Sato, Takahiro; Koka, Masashi; Ishii, Yasuyuki; Kamiya, Tomihiro; Nishikawa, Hiroyuki*; et al.
Nuclear Instruments and Methods in Physics Research B, 348, p.218 - 222, 2015/04
Times Cited Count:6 Percentile:45.92(Instruments & Instrumentation)Usui, Aya; Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; et al.
Dai-27-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.118 - 121, 2015/03
no abstracts in English
Okubo, Takeru; Ishii, Yasuyuki
Review of Scientific Instruments, 86(3), p.036102_1 - 036102_3, 2015/03
Times Cited Count:2 Percentile:10.19(Instruments & Instrumentation)Ishii, Yasuyuki; Okubo, Takeru; Kojima, Takuji; Kamiya, Tomihiro
Nuclear Instruments and Methods in Physics Research B, 332, p.156 - 159, 2014/08
Times Cited Count:7 Percentile:48.36(Instruments & Instrumentation)Sakai, Takuro; Yasuda, Ryo; Iikura, Hiroshi; Nojima, Takehiro; Koka, Masashi; Sato, Takahiro; Ishii, Yasuyuki; Oshima, Akihiro*
Nuclear Instruments and Methods in Physics Research B, 332, p.238 - 241, 2014/08
Times Cited Count:1 Percentile:10.25(Instruments & Instrumentation)We have successfully fabricated novel microscopic imaging devices made from UV/EB curable resin using an external scanning proton microbeams. The devices are micro-structured fluorescent plates that consist of an array of micro-pillars that align periodically. The base material used in the pillars is UV/EB curable resin and each pillar contains phosphor grains. The pattern exposures were performed using a proton beam writing technique. The height of the pillars depends on the range of the proton beam. Optical microscopy and scanning electron microscopy have been used to characterize the samples. The results show that the fabricated fluorescent plates are expected to be high-spatial-resolution imaging devices.
Yamada, Keisuke; Saito, Yuichi; Ishii, Yasuyuki; Matoba, Shiro; Chiba, Atsuya; Yokoyama, Akihito; Usui, Aya; Sato, Takahiro; Okubo, Takeru; Uno, Sadanori
JAEA-Review 2013-059, JAEA Takasaki Annual Report 2012, P. 159, 2014/03
no abstracts in English
Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Usui, Aya; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Okubo, Takeru; Nara, Takayuki; et al.
JAEA-Review 2013-059, JAEA Takasaki Annual Report 2012, P. 179, 2014/03
Three electrostatic accelerators at TIARA were operated on schedule in fiscal year 2012 except changing its schedule by cancellations of users. The yearly operation time of the 3 MV tandem accelerator, the 400 kV ion implanter and the 3MV single-ended accelerator were in the same levels as the ordinary one, whose operation time totaled to 2,073, 1,847 and 2,389 hours, respectively. The tandem accelerator had no trouble, whereas the ion implanter and the single-ended accelerator stopped by any troubles for one day and four days, respectively. The molecular ion beam of helium hydride was generated by the ion implanter, because the users required irradiation of several cluster ions in order to study the effect of irradiation. As a result, its intensity of beam was 50 nA at 200 kV. The ion beam of tungsten (W) at 15 MeV was accelerated by the tandem accelerator, whose intensity was 20 nA at charge state of 4+, because of the request from a researcher in the field of nuclear fusion.
Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Usui, Aya; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; et al.
Dai-26-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.79 - 81, 2013/07
Three electrostatic accelerators at TIARA were operated on schedule in fiscal year 2012 except changing its schedule by cancellations of users. The yearly operation time of the 3MV tandem accelerator, the 400 kV ion implanter and the 3 MV single-ended accelerator were in the same levels as the ordinary one, whose operation time totaled to 2,073, 1,847 and 2,389 hours, respectively. The tandem accelerator had no trouble, whereas the ion implanter and the single-ended accelerator stopped by any troubles for one day and four days, respectively. The ion implanter generated molecular ion beam of helium hydride by using the Freeman type ion source, because of the request from the user. As a result, its intensity of beam was 50 nA at 200 kV.
Sakai, Takuro; Yasuda, Ryo; Iikura, Hiroshi; Nojima, Takehiro; Matsubayashi, Masahito; Kada, Wataru; Koka, Masashi; Sato, Takahiro; Okubo, Takeru; Ishii, Yasuyuki; et al.
Nuclear Instruments and Methods in Physics Research B, 306, p.299 - 301, 2013/07
Times Cited Count:7 Percentile:49.28(Instruments & Instrumentation)Okubo, Takeru; Ishii, Yasuyuki; Miyake, Yoshinobu*; Kamiya, Tomihiro
AIP Conference Proceedings 1525, p.370 - 374, 2013/04
Times Cited Count:4 Percentile:83.66(Physics, Applied)Yamada, Keisuke; Chiba, Atsuya; Yokoyama, Akihito; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Okubo, Takeru; Uno, Sadanori
JAEA-Review 2012-046, JAEA Takasaki Annual Report 2011, P. 155, 2013/01
no abstracts in English