Maintenance management of emergency power supply equipment (uninterruptible power supply) in Tokai reprocessing plant

Nishida, Kyosuke; Hiyama, Hisao; Shibata, Satomi; Iwasaki, Shogo; Inami, Shinichi

Nihon Hozen Gakkai Dai-6-Kai Gakujutsu Koenkai Yoshishu, p.294 - 297, 2009/08

Uninterruptible power supply systems are installed in the Tokai reprocessing plant in preparation for the emergency case that the commercial power supply is stopped by an accidental or intentional interruption in the supply of electricity. The uninterruptible power supply system particularly provides a temporary power source to the important devices for the radiation control of nuclear critical monitoring in the plant. Thus, the system is potentially important and essential for nuclear plants. The paper repots the current activities such as regular inspections, replacement of parts and system update, to maintain the function of uninterruptible power supply systems.

Journal Articles

Status of J-PARC muon science facility at the year of 2005

Miyake, Yasuhiro*; Nishiyama, Kusuo*; Kawamura, Naritoshi*; Makimura, Shunsuke*; Strasser, P.*; Shimomura, Koichiro*; Beveridge, J. L.*; Kadono, Ryosuke*; Fukuchi, Koichi*; Sato, Nobuhiko*; et al.

Physica B; Condensed Matter, 374-375, p.484 - 487, 2006/03

 Times Cited Count:6 Percentile:31.27(Physics, Condensed Matter)

The construction of the Materials and Life Science building was started in the beginning of the fiscal year of 2004. After commissioning of the accelerator and beam transport sections in 2008, muon beams will be available for users in 2009. In this letter, the latest construction status of the J-PARC Muon Science Facility is reported.

Journal Articles

J-PARC muon science facility with use of 3GeV proton beam

Miyake, Yasuhiro*; Kawamura, Naritoshi*; Makimura, Shunsuke*; Strasser, P.*; Shimomura, Koichiro*; Nishiyama, Kusuo*; Beveridge, J. L.*; Kadono, Ryosuke*; Sato, Nobuhiko*; Fukuchi, Koichi*; et al.

Nuclear Physics B; Proceedings Supplements, 149, p.393 - 395, 2005/12

The J-PARC muon science experimental area is planned to be located in the integrated building of the facility for materials and life science study. One muon target will be installed upstream of the neutron target. The main feature of the facility is introduced.

JAEA Reports

Reconstruction of CT images by the Bayes-back projection method

Haruyama, Mitsuo; Takase, Misao*; Iwasaki, Shin*; Tobita, Hiroshi

JAERI-Research 2002-022, 91 Pages, 2002/12

JAERI-Research-2002-022.pdf:37.97MB

In the course of research on quantitative assay of non-destructive measurement of radioactive waste, the authors have developed a unique program based on the Bayesian theory for reconstruction of transmission computed tomography (TCT) image. The reconstruction of cross-section images in the CT technology usually employs the Filtered Back Projection method. The new imaging reconstruction program reported here is based on the Bayesian Back Projection method, and it has a function of iterative improvement images by every step of measurement. Namely, this method has the capability of prompt display of a cross-section image corresponding to each angled projection data from every measurement. Hence, it is possible to observe an improved cross-section view by reflecting each projection data in almost real time. The present reconstruction program developed here for the $$gamma$$-ray CT can widely applied also to, for instance, the Neutron Imaging and the Positron Emission Tomography (PET).

JAEA Reports

None

; Sakai, Toshiyuki*; Sanyoshi, Hirotaka; Iwasaki, Isao*; Kuribayashi, Masakazu*;

PNC TN8410 95-056, 65 Pages, 1995/03

PNC-TN8410-95-056.pdf:2.87MB

None

JAEA Reports

None

Nemoto, Shinichi; Sakai, Toshiyuki*; Sanyoshi, Hirotaka; Kikuchi, Kenji; Iwasaki, Isao*; Kuribayashi, Masakazu*; Matsushima, Kazumi*

PNC TN8410 93-283, 86 Pages, 1993/11

PNC-TN8410-93-283.pdf:2.38MB

None

Oral presentation

The Construction of an intensive monitoring system for power supply stations in the Tokai reprocessing plant

Aoki, Kenji; Hiyama, Hisao; Shibata, Satomi; Iwasaki, Shogo; Inami, Shinichi

no journal, , 

There are plural facilities having a radiation controlled area in the Tokai reprocessing plant, and an uninterruptible power supply system which considered a blackout is necessary for the power supply to each facility from the viewpoint of radiological management and nuclear material containment. In addition, at the time of the power supplying abnormality, intelligence gathering is necessary for prompt measures and restoration. In this report, the intensive monitoring system, which aimed for the unification of the power supply monitor place and the acceleration of the intelligence gathering to detect a power supply abnormality point, is described.

Oral presentation

Liquid leakage from the sea release pipe of the Tokai reprocessing plant; Restoration of the leak point of the see release pipe

Aoki, Kenji; Shimizu, Kazuyuki; Yamamoto, Masahiko; Takeuchi, Kenji; Hiyama, Hisao; Iwasaki, Shogo

no journal, , 

no abstracts in English

Oral presentation

Current status and issues of low dose and low dose rate radiation risk estimation method; Current status and issues of dose assessment

Sakai, Kazuo*; Yamada, Yu*; Yoshida, Kazuo*; Yoshinaga, Shinji*; Sato, Kaoru; Ogata, Hiromitsu*; Iwasaki, Toshiharu*; Kudo, Shinichi*; Asada, Kyosei*; Kawaguchi, Isao*; et al.

no journal, , 

Task Group of Low dose and Low Dose Rate Radiation Risk Estimation Method in the Japan Health Physics Society presented the task group activity from April, 2016 to March, 2018. The presenter introduce the current status and issues of dose assessment (e.g. effects of anatomical characteristics of subjects, monitoring data, distribution of dose and dose rate in body on uncertainty of dose assessment).

9 (Records 1-9 displayed on this page)
  • 1