Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Joung, S.*; Ji, Y.-Y.*; Choi, Y.*; Lee, E.*; Ji, W.*; 佐々木 美雪; 越智 康太郎; 眞田 幸尚
Journal of Instrumentation (Internet), 20(4), p.P04027_1 - P04027_10, 2025/04
被引用回数:0An airborne survey system named the MARK-A1 was previously developed to be mounted on an unmanned aerial vehicle for the purpose of application in contaminated areas with high dose rate levels. The MARK-A1 system consists of a CZT detector, signal processing unit, and positioning and interface units linked to a PC on the ground. The weight of the system is below 1 kg for loading on a commercial drone. In the current work, for experimental verification, field testing was conducted in a high dose rate environment near the Fukushima Daiichi Nuclear Power Plant. With the cooperation of the Japan Atomic Energy Agency, the MARK-A1 was installed on an unmanned aerial vehicle to conduct airborne surveys using two flight methods, namely a flat flight and a step flight, at various speeds. The airborne survey data were converted to gamma dose rates at a height of 1 m above the ground using a flat source model to create contamination maps. For a comparative evaluation of the airborne survey results, an in situ survey was also conducted in the survey area, and it was confirmed that the step flight method better matched the surface survey results.
Kim, H.-S.*; Jeon, Y. M.*; Na, Y.-S.*; Ghim, Y.-C.*; Ahn, J.-W.*; Yoon, S. W.*; Bak, J. G.*; Bae, Y. S.*; Kim, J. S.*; Joung, M.*; et al.
Nuclear Fusion, 54(8), p.083012_1 - 083012_11, 2014/08
被引用回数:9 パーセンタイル:38.86(Physics, Fluids & Plasmas)KSTARのLモードおよびHモードプラズマにおいてエネルギー閉じ込め特性を定量的に評価し、多変数回帰解析を行い多装置スケーリング則と比較した。解析したKSTARプラズマのエネルギー閉じ込め時間はLモードで0.04-0.16秒、Hモードで0.06-0.19秒の範囲にある。多変数回帰解析によると、閉じ込め時間は多装置スケーリング則と比較して損失パワーに関しては同程度の、プラズマ電流に関してはわずかに強い依存性が見られた。一方で、非円形度に関しては多装置スケーリング則が正の冪乗依存性を示すのに対してKSTARでは負の冪乗依存性を示した(Lモードで-0.68乗、Hモードで-0.76乗)。KSTARでは非円形度の増加と共にダイバータ足位置が移動するため、不純物の混入量が増加して閉じ込めを劣化させているなどの原因が考えられる。
Jeong, J. H.*; Bae, Y. S.*; Joung, M.*; Kim, H. J.*; Park, S. I.*; Han, W. S.*; Kim, J. S.*; Yang, H. L.*; Kwak, J. G.*; 坂本 慶司; et al.
Fusion Engineering and Design, 88(5), p.380 - 387, 2013/06
被引用回数:4 パーセンタイル:30.59(Nuclear Science & Technology)A 3.6 MW DC power supply system was developed for the 170 GHz EC H&CD system in KSTAR. It consists of a cathode power supply (CPS), an anode power supply (APS) and a body power supply (BPS). The CPS is capable of supplying a voltage of -66 kV and a current of 55 A to the cathode with respect to the collector using pulse step modulation (PSM). The APS is a voltage divider system consisting of a fixed resistor and zener diode units with the capability of 60 kV stand-off voltage. For high frequency current modulation, the parallel discharge switch is introduced between the cathode and anode. The BPS is a DC power supply with 50 kV/160 mA. The series MOS-FET solid-state switch is used for on/off modulation in the body voltage sychronizing with anode voltage. The parallel discharge switch is also introduced between the body and collector for high frequency RF modulation. This paper describes the key features of the high voltage power supply system as well as the test results.
Yang, H. L.*; Kim, Y. S.*; Park, Y. M.*; Bae, Y. S.*; Kim, H. K.*; Kim, K. M.*; Lee, K. S.*; Kim, H. T.*; Bang, E. N.*; Joung, M.*; et al.
Proceedings of 23rd IAEA Fusion Energy Conference (FEC 2010) (CD-ROM), 8 Pages, 2011/03
韓国超伝導トカマク先進研究装置(KSTAR)における高楕円度でダイバータ配位を有するプラズマ生成を目指した2010年の運転のため、プラズマ形状制御に不可欠なハードウェア・システムが新たに据え付けられ改良された。この論文では、改良されたシステムの一般的な構成の概要を述べる。さらに、システムにおいてキーとなる幾つかの性能と試験結果についても報告する。
Stober, J.*; Jackson, G. L.*; Ascasibar, E.*; Bae, Y.-S.*; Bucalossi, J.*; Cappa, A.*; Casper, T.*; Cho, M. H.*; Gribov, Y.*; Granucci, G.*; et al.
Proceedings of 23rd IAEA Fusion Energy Conference (FEC 2010) (CD-ROM), 8 Pages, 2010/10
ECRH assisted plasma breakdown is foreseen with full and half magnetic field in ITER. As reported earlier, the corresponding O1- and X2-schemes have been successfully used for pre-ionisation and breakdown assist in present day devices. This contribution reports on common experiments studying the effect of toroidal inclination of the ECR beam, which is in ITER. All devices could demonstrate successful breakdown assist also for this case, although in some experiments the necessary power was almost a factor of two higher compared to perpendicular launch. Differences between the devices with regard to the required power and vertical field are discussed and analysed. In contrast to most of these experiments, ITER will build up loop voltage prior to the formation of the field null due to the strong shielding by the vessel. Possible consequences of this difference are discussed.
Na, Y. S.*; 鈴木 隆博; 井手 俊介; Mueller, D.*; Kim, J. H.*; 宮田 良明; Kim, S. H.*; Kim, H. S.*; Jeon, Y. M.*; Bae, Y. S.*; et al.
no journal, ,
KSTARプロジェクトの重要な実験目標である先進シナリオ開発を開始した。プラズマ電流立ち上げ初期にダイバータ配位を形成し、その後に加熱を行いつつ電流を立ち上げることで先進シナリオに適した鋸歯状不安定性のないターゲットプラズマの生成に成功した。さらにこのプラズマに対して、高いポロイダルベータ値と自発電流割合を得て磁気シアを変化させるためにJET装置で用いられている「Ipオーバーシュート」法を適用した。これら一連のプラズマについて、平衡及び輸送と加熱・電流駆動を考慮した統合シミュレーションコードを用いて閉じ込めと輸送特性を調べた。プラズマ電流立ち上げ中の安全係数、電流立ち上げ後の閉じ込め特性、自発電流を含む非誘導駆動電流について議論する。また、これらのプラズマを他のトカマク装置で開発された先進シナリオと比較し、今後のKSTAR先進シナリオ開発の方向性も議論する。
Joung, S.*; Ji, Y.-Y.*; Choi, Y.*; Lee, E.*; Ji, W.*; 佐々木 美雪; 越智 康太郎; 眞田 幸尚
no journal, ,
韓国原子力研究院は、汚染地域での利用を目的に無人航空機に搭載する上空からの測定システム「MARK A1」を開発した。MARK A1システムは、CZT検出器、信号処理ユニット、地上のPCへの測位・インターフェースユニットで構成されている。検出器の有効性を検証するために、福島第一原子力発電所付近の高線量率環境下でフィールドテストを実施した。日本原子力研究開発機構と韓国原子力研究院の検出器をそれぞれ、無人ヘリコプターに搭載し、異なる高度で測定を行った。両システムとも上空からの測定で得られた空間線量率は、歩行サーベイで得られた空間線量率と同様の傾向の結果を得ることができた。そのため、MARK A1は原子力事故発生時に人間が立ち入ることが困難な広大で高濃度の汚染された地域を、迅速にスキャンするために使用できることが期待されている。
佐々木 美雪; 眞田 幸尚; Lee, E.*; Joung, S.*; Ji, Y.-Y.*
no journal, ,
福島第一原子力発電所の事故以降、日本では複数種類の放射線モニタリングが実施された。FDNPP周辺では、歩行調査や無人ヘリコプターによる調査が行われ、周辺線量当量率(空間線量率)が測定されている。無人ヘリコプターによる放射線モニタリング(ARS)は、森林を含む広い範囲を測定できる利点がある。しかし、ARSは歩行型サーベイに比べ測定分解能が低いというデメリットがある。佐々木らは、事故後に蓄積されたデータを用いて、ARSのデータを地上1mの空間線量率に変換する人工ニューラルネットワーク(ANN)を構築した。ANNを用いた変換は、従来の方法よりも地上での測定値に近い値に変換できることが報告されている。福島の経験から構築したANNが、ANNの構築に使用した放射線検出器以外の検出器にも適用できることを示すことは、今後のARSの発展に大きく寄与する。そこで本研究では、学習データの取得に用いた放射線検出器とは異なる検出器で取得した放射線測定データを、既に構築されたANNに適用する方法を検討した。