Watakabe, Tomoyoshi; Kaneko, Naoaki*; Aida, Shigekazu*; Otani, Akihito*; Tsukimori, Kazuyuki; Moriizumi, Makoto; Kitamura, Seiji
Dynamics and Design Conference 2013 (D&D 2013) Koen Rombunshu (USB Flash Drive), 8 Pages, 2013/08
The piping in a nuclear power plant is laid across multiple floors of a single building or two buildings, which are supported at many anchors. As the piping is excited by multiple inputs from the supporting anchors during an earthquake, seismic response analysis by multiple excitations is needed to obtain the exact seismic response of the piping. However, few tests involving such multiple excitations have been performed to verify the validity of multiple excitation analysis. To perform rational seismic design and evaluation, it is important to investigate the seismic response by multiple excitations and verify the validity of the analysis method by multiple excitation test. This paper reports on the result of the shaking test using triple uni-axial shaking tables and a 3-dimensional piping model.
Watakabe, Tomoyoshi; Kaneko, Naoaki*; Aida, Shigekazu*; Otani, Akihito*; Moriizumi, Makoto*; Tsukimori, Kazuyuki; Kitamura, Seiji
Proceedings of 2013 ASME Pressure Vessels and Piping Conference (PVP 2013) (DVD-ROM), 8 Pages, 2013/07
The piping in a nuclear power plant is laid across multiple floors of a single building or two buildings, which are supported at many points. As the piping is excited by multiple inputs from the supporting points during an earthquake, seismic response analysis by multiple excitations is needed to obtain the exact seismic response of the piping. However, few experiments involving such multiple excitations have been performed to verify the validity of multiple excitation analysis. To perform rational seismic design and evaluation, it is important to investigate the seismic response by multiple excitations and verify the validity of the analysis method by multiple excitation test. This paper reports on the result of the shaking test using triple uni-axial shaking tables and a 3-dimensional piping model.
Oka, Yoshihide*; Tsumori, Katsuyoshi*; Ikeda, Katsunori*; Kaneko, Osamu*; Nagaoka, Kenichi*; Osakabe, Masaki*; Takeiri, Yasuhiko*; Asano, Eiji*; Komada, Seiji*; Kondo, Tomoki*; et al.
Review of Scientific Instruments, 79(2), p.02C105_1 - 02C105_4, 2008/02
Times Cited Count:0 Percentile:0.01(Instruments & Instrumentation)In the present studies, we studied the cesium lines in the source plasma during beam shots on the LND MN-NBI system. It was found for the first time in the LHD-source 2, that both the amount of Cs I (neutral Cs) and Cs II (Cs) in the source plasma light rose sharply when beam acceleration began, and continued rising during a 10 s pulse. We think that this was because the cesium was evaporated/sputtered from the source backplate by the back-streaming positive ions.
Kaneko, Naoaki*; Kitamura, Seiji; Jimbo, Noboru*; Mizutani, Takumi*; Otani, Akihito*
no journal, ,
no abstracts in English
Okumura, Keisuke; Sakamoto, Masahiro; Tada, Kenichi; Nishihara, Kenji; Mizokami, Shinya*; Mizokami, Masato*; Miki, Yosuke*; Kaneko, Seiji*
no journal, ,
no abstracts in English
Sakamoto, Masahiro; Okumura, Keisuke; Tada, Kenichi; Nishihara, Kenji; Mizokami, Shinya*; Mizokami, Masato*; Miki, Yosuke*; Kaneko, Seiji*
no journal, ,
no abstracts in English
Sakamoto, Masahiro; Okumura, Keisuke; Tada, Kenichi; Nishihara, Kenji; Mizokami, Shinya*; Mizokami, Masato*; Miki, Yosuke*; Kaneko, Seiji*
no journal, ,
no abstracts in English