Refine your search:     
Report No.
 - 
Search Results: Records 1-2 displayed on this page of 2
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Oral presentation

Ibaraki materials design diffractometer for J-PARC

Ishigaki, Toru; Hoshikawa, Akinori; Yonemura, Masao*; Kamiyama, Takashi*; Harjo, S.; Aizawa, Kazuya; Sakuma, Takashi*; Tomota, Yo*; Morii, Yukio; Arai, Masatoshi; et al.

no journal, , 

Ibaraki prefecture, the local goverment of the area for J-PARC site, was decided to build a versatile neutron diffractometer (IBARAKI Materials Design Diffractometer) to promote a industrial application for neutron beam in J-PARC. This diffractometer is planned to be a high throughput diffractometer so that materials engineers and scientists can use it like the chemical analytical instruments in their materials development process. It covers in d range 0.18 $$<$$ d (${AA}$) $$<$$ 5 with $$Delta $$ $$d/d$$ = 0.16% at high resolution bank, and covers 5 $$<$$ d (${AA}$) $$<$$ 800 with gradually changing resolution at three detector bank (90 degree, low angle and small angle). Typical measuring time to obtain a "Rietveld-quality" data is several minutes with the sample size of laboratory X-ray diffractometer. To promote industrial application, a utilization system for this diffractometer is required. We will establish a support system for both academic and industrial users who are willing to use neutron but have not been familiar with neutron diffraction. The construction of this instrument was already begun and will be compleated in the beggining of 2008, as one of day-one instruments for J-PARC.

Oral presentation

IBARAKI materials design diffractometer; Versatile neutron diffractometer at J-PARC

Ishigaki, Toru; Hoshikawa, Akinori; Yonemura, Masao*; Kamiyama, Takashi*; Aizawa, Kazuya; Sakuma, Takashi*; Tomota, Yo*; Morii, Yukio; Arai, Masatoshi; Hayashi, Makoto*; et al.

no journal, , 

Ibaraki prefecture, the local government of the area for J-PARC site, was decided to build a versatile neutron diffractometer (IBARAKI Materials Design Diffractometer) to promote an industrial application for neutron beam in J-PARC. This diffractometer is planned to be a high throughput diffractometer so that materials engineers and scientists can use it like the chemical analytical instruments in their materials development process. It covers in d range 0.18 $$<$$ d (${AA}$) $$<$$ 5 with $$Delta$$ d/d = 0.16 % at high resolution bank, and covers $$<$$ d (${AA}$) $$<$$ 800 with gradually changing resolution at three detector bank (90 degree, low angle and small angle). Typical measuring time to obtain a "Rietveld-quality" data is several minutes with the sample size of laboratory X-ray diffractometer. To promote industrial application, a utilization system for this diffractometer is required. We will establish a support system for both academic and industrial users who are willing to use neutron but have not been familiar with neutron diffraction. The construction of this instrument was already beginning and will be completed in the beginning of 2008, as one of day-one instruments for J-PARC. The current status for this instrument also will be reported.

2 (Records 1-2 displayed on this page)
  • 1