Nakano, Tomohide; Shumack, A.*; Maggi, C. F.*; Reinke, M.*; Lawson, K.*; Coffey, I.*; Ptterich, T.*; Brezinsek, S.*; Lipschultz, B.*; Matthews, G. F.*; et al.
Journal of Physics B; Atomic, Molecular and Optical Physics, 48(14), p.144023_1 - 144023_11, 2015/07
Times Cited Count:30 Percentile:82.76(Optics)The and 3p-4d inner shell excitation lines in addition to 2p-3s lines have been identified from the spectrum taken by an upgraded high-resolution X-ray spectrometer. It is found from analysis of the absolute intensities of the and lines that W and Mo concentrations are in the range of and , respectively, with a ratio of 5% for ELMy H-mode plasmas with a plasma current of 2.0- 2.5 MA, a toroidal magnetic field of 2.7 T and a neutral beam injection power of 14-18 MW. For the purpose of checking self-consistency, it is confirmed that the W concentration determined from the line is in agreement with that from the line within 20% and that the plasma effective charge determined from the continuum of the first order reflection spectrum is also in agreement with that from the second order within 50%. Further, the determined plasma effective charge is in agreement with that determined from a visible spectroscopy, confirming that the sensitivity of the X-ray spectrometer is valid and that probably the W and the Mo concentrations are also valid.
Nakano, Tomohide; Shumack, A. E.*; Maggi, C.*; Reinke, M.*; Lawson, K. D.*; Ptterich, T.*; Brezinsek, S.*; Lipschultz, B.*; Matthews, G.*; Chernyshova, M.*; et al.
Europhysics Conference Abstracts (Internet), 38F, p.P1.019_1 - P1.019_4, 2014/06
no abstracts in English
Nakano, Tomohide; Shumack, A.*; Maggi, C. F.*; Reinke, M.*; Lawson, K.*; Ptterich, T.*; Brezinsek, S.*; Lipschultz, B.*; Matthews, G. F.*; Chernyshova, M.*; et al.
no journal, ,
In an European tokamak device, JET, an existing high-resolution X-ray crystal spectrometer was upgraded together with installation of the W divertor for the purpose of monitoring the W density in the core plasma. We have identified W, W and Mo lines by comparing the spectrum observed by this spectrometer and that calculated by an atomic structure code. Further, from the intensities of these spectral lines, the W density and the Mo density over an electron density were determined to be and , respectively. The determined W density was in good agreement with that from another spectrometer. In addition, the plasma effective charge evaluated from the continuum intensity observed by the X-ray spectrometer was in agreement with that from a visible spectrometer within a factor of three. From these agreements, it is probable that the determined W and Mo density are valid. In contrast, the determined W density is only 15% compared with that from an soft X-ray array measurement. This inconsistency will be investigated in the near future.