Kiriyama, Hiromitsu; Mori, Michiaki; Okada, Hajime; Shimomura, Takuya; Nakai, Yoshiki*; Tanoue, Manabu; Kondo, Shuji; Kanazawa, Shuhei; Yogo, Akifumi; Sagisaka, Akito; et al.
JPS Conference Proceedings (Internet), 1, p.015095_1 - 015095_5, 2014/03
We present the design and characterization of a high-contrast, petawatt-class Ti:sapphire chirped-pulse amplification (CPA) laser system. Two saturable absorbers and low-gain optical parametric chirped-pulse amplification (OPCPA) preamplifier in the double CPA laser chain have improved the temporal contrast to 1.410 on the subnanosecond time scale at 70 terawatt level. Final uncompressed broadband pulse energy is 28 J, indicating the potential for reaching peak power near 600 terawatt. We also discuss our upgrade to over petawatt level at a 0.1 Hz repetition rate briefly.
Sakaki, Hironao; Nishiuchi, Mamiko; Maeda, Shota; Sagisaka, Akito; Pirozhkov, A. S.; Pikuz, T.; Faenov, A.*; Ogura, Koichi; Fukami, Tomoyo; Matsukawa, Kenya*; et al.
Review of Scientific Instruments, 85(2), p.02A705_1 - 02A705_4, 2014/02
Times Cited Count:2 Percentile:11.31(Instruments & Instrumentation)High intensity laser-plasma interaction has attracted considerable interest for a number of years. The laser-plasma interaction is accompanied by generation of various charged particle beams. Results of simultaneous novel measurements of electron-induced photonuclear neutrons (photoneutron), which are a diagnostic of the laser-plasma interaction, are proposed to use for optimization of the laser-plasma ion generation. The proposed method is demonstrated by the laser irradiation with the intensity os 110 W/cm on the metal foil target. The photoneutrons are measured by using NE213 liquid scintillation detectors. Heavy-ion signal is registered with the CR39 track detector simultaneously. The measured signals of the electron-induced photoneutrons are well reproduced by using the Particle and Heavy Ion Transport code System (PHITS). The results obtained provide useful approach for analyzing the various laser based ion beams.
Sagisaka, Akito; Pirozhkov, A. S.; Nishiuchi, Mamiko; Ogura, Koichi; Sakaki, Hironao; Yogo, Akifumi; Mori, Michiaki; Kiriyama, Hiromitsu; Okada, Hajime; Kanazawa, Shuhei; et al.
Reza Kenkyu, 42(2), p.160 - 162, 2014/02
High-intensity laser and thin-foil interactions produce high-energy particles, hard X-ray, high-order harmonics, and terahertz radiation. A proton beam driven by a high-intensity laser has received attention as a compact ion source for medical and other applications. We have measured the proton yield from thin-foil targets irradiated with a high-intensity Ti:sapphire laser (J-KAREN) at JAEA. The longitudinal extent of the preformed plasma protruding from the front surface of the target is reduced by decreasing the duration of the amplified spontaneous emission (ASE) before the main pulse. The maximum proton energy in the target normal direction increases when the size of the preformed plasma is controlled.
Kiriyama, Hiromitsu; Shimomura, Takuya; Mori, Michiaki; Nakai, Yoshiki*; Tanoue, Manabu; Kondo, Shuji; Kanazawa, Shuhei; Pirozhkov, A. S.; Esirkepov, T. Z.; Hayashi, Yukio; et al.
Applied Sciences (Internet), 3(1), p.214 - 250, 2013/03
Times Cited Count:15 Percentile:50(Chemistry, Multidisciplinary)This paper reviews techniques for improving the temporal contrast and spatial beam quality in an ultra-intense laser system that is based on chirped-pulse amplification (CPA). We describe the design, performance, and characterization of our laser system, which has the potential for achieving a peak power of 600 TW. We also describe applications of the laser system in the relativistically dominant regime of laser-matter interactions and discuss a compact, high efficiency diode-pumped laser system.
Iwamoto, Yukiharu*; Kondo, Manabu*; Minamiura, Hirotaka*; Tanaka, Masaaki; Yamano, Hidemasa
Journal of Fluid Science and Technology (Internet), 7(3), p.315 - 328, 2012/08
LDV measurements in a 90 degree elbow of which the curvature radius coincides with its inner diameter were examined for the cases of inflow from a long pipe, short pipe and swirl generator. Ensemble averaged flow distribution at the Reynolds number of 320000 based on the inner pipe diameter and bulk velocity shows that shortening the upstream pipe length to 4.9D from 10D induces the flow separation downstream of the elbow.
Iwamoto, Yukiharu*; Kondo, Manabu*; Ogawa, Shota*; Tanaka, Masaaki; Yamano, Hidemasa
Nihon Kikai Gakkai Rombunshu, B, 78(792), p.1383 - 1387, 2012/08
LDV measurements in a 90 degrees elbow which curvature radius coincides with the diameter have been conducted. This paper especially focuses on a result of the deflected inflow, comparing with a result of the short pipe. The result shows that the deflected inflow reinforced a convex velocity distribution occurring near the curvature inside in the downstream region, concluding that the deflected inflow promotes the secondary flow of Prandtl's first kind in the elbow. Its Strouhal number increases to 0.6 from 0.5, compared with the short pipe case. Results of frequency analyses are also shown for other cases that we have been examined. Dominant Strouhal numbers in most of the cases become 0.5, except for 0.6 in cases of the inflow from the long pipe and deflector. This frequency shift might be related with the boundary layer size and the local flow velocity, since the corresponding fluctuation is caused by vortex shedding from the boundary layer at the elbow inside.
Kiriyama, Hiromitsu; Shimomura, Takuya; Sasao, Hajime; Nakai, Yoshiki*; Tanoue, Manabu; Kondo, Shuji; Kanazawa, Shuhei; Pirozhkov, A. S.; Mori, Michiaki; Fukuda, Yuji; et al.
Optics Letters, 37(16), p.3363 - 3365, 2012/08
Times Cited Count:38 Percentile:85.95(Optics)We demonstrate the temporal contrast enhancement in a petawatt-class Ti:sapphire chirped-pulse amplification (CPA) laser system. An extra saturable absorber, introduced downstream a low gain optical parametric chirped-pulse amplification (OPCPA) preamplifier, has improved the temporal contrast in the system to 1.410 on the sub-nanosecond time scale at 70 TW power level. We have achieved 28 J of uncompressed broadband output energy with this system, indicating the potential for reaching peak powers near 600 TW.
Ogura, Koichi; Shizuma, Toshiyuki; Hayakawa, Takehito; Yogo, Akifumi; Nishiuchi, Mamiko; Orimo, Satoshi; Sagisaka, Akito; Pirozhkov, A. S.; Mori, Michiaki; Kiriyama, Hiromitsu; et al.
Japanese Journal of Applied Physics, 51(4), p.048003_1 - 048003_2, 2012/04
Times Cited Count:2 Percentile:8.97(Physics, Applied)A proton beam driven by a repetitive high-intensity-laser is utilized to induce a Li(p,n)Be nuclear reaction. The total activity of Be are evaluated by two different methods. The activity obtained measuring the decay -rays after 1912 shots at 1 Hz is 1.70.2 Bq. This is in good agreement with 1.60.3 Bq evaluated from the proton energy distribution measured using a time-of-flight detector and the nuclear reaction cross-sections. We conclude that the production of activity can be monitored in real time using the time-of-flight-detector placed inside a diverging proton beam coupled with a high-speed signal processing system.
Iwamoto, Yukiharu*; Kondo, Manabu*; Yasuda, Kazunori*; Sogo, Motosuke*; Tanaka, Masaaki; Yamano, Hidemasa
Proceedings of 19th International Conference on Nuclear Engineering (ICONE-19) (CD-ROM), 10 Pages, 2011/10
Kotaki, Hideyuki; Kando, Masaki; Daito, Izuru; Kameshima, Takashi*; Kawase, Keigo*; Chen, L. M.*; Fukuda, Yuji; Koga, J. K.; Kiriyama, Hiromitsu; Kondo, Shuji; et al.
Japanese Journal of Applied Physics, 50(6), p.066401_1 - 066401_3, 2011/06
Times Cited Count:1 Percentile:4.8(Physics, Applied)Yogo, Akifumi; Maeda, Takuya; Hori, Toshihiko; Sakaki, Hironao; Ogura, Koichi; Nishiuchi, Mamiko; Sagisaka, Akito; Kiriyama, Hiromitsu; Okada, Hajime; Kanazawa, Shuhei; et al.
Applied Physics Letters, 98(5), p.053701_1 - 053701_3, 2011/02
Times Cited Count:95 Percentile:94.27(Physics, Applied)Sagisaka, Akito; Pirozhkov, A. S.; Mori, Michiaki; Yogo, Akifumi; Ogura, Koichi; Orimo, Satoshi; Nishiuchi, Mamiko; Ma, J.*; Kiriyama, Hiromitsu; Kanazawa, Shuhei; et al.
NIFS-PROC-85, p.30 - 33, 2011/02
The experiment of proton generation is performed for developing the laser-driven ion source. We observe proton signals in the laser-plasma interaction by using a thin-foil target. To get higher energy protons the size of the preformed plasma is reduced by changing the laser contrast level. In the high-contrast laser pulse case the maximum energy of the protons generated at rear side of the target increases.
Kiriyama, Hiromitsu; Mori, Michiaki; Nakai, Yoshiki*; Shimomura, Takuya; Sasao, Hajime*; Tanaka, Momoko; Ochi, Yoshihiro; Tanoue, Manabu*; Kondo, Shuji; Kanazawa, Shuhei; et al.
Reza Kenkyu, 38(9), p.669 - 675, 2010/09
This paper reviews the temporal contrast and spatial beam quality improvement techniques in a high intensity Ti:sapphire laser system that is based on chirped-pulse amplification (CPA). We describe a low gain optical parametric chirped-pulse amplification (OPCPA) preamplifier that uses high energy, clean pulse seeding and is shown to significantly improve the contrast to better than 10-10 relative to the peak of the main femtosecond pulse. We also report the use of a diffractive optical element for beam homogenization of a 100 J level Nd:glass green pump laser, achieving a flat-topped spatial profile with a filling factor near 80 %.
Sagisaka, Akito; Pirozhkov, A. S.; Mori, Michiaki; Yogo, Akifumi; Ogura, Koichi; Orimo, Satoshi; Nishiuchi, Mamiko; Ma, J.*; Kiriyama, Hiromitsu; Kanazawa, Shuhei; et al.
Reza Kenkyu, 38(9), p.702 - 705, 2010/09
High-intensity laser and thin-foil interactions produce high-energy particles, hard X-ray, high-order harmonics, and terahertz (THz) radiation. A proton beam driven by a high-intensity laser has received attention as a compact ion source for medical applications. In this study we have tested simultaneous generation of protons and THz radiation from a thin-foil target. We use a Ti:sapphire laser system (J-KAREN) at JAEA. A laser beam is focused by an off-axis parabolic mirror at the thin-foil target. We observed the high-energy proton in the rear side of the target and THz radiation in the reflected direction. Next, high energy protons are observed by reducing the size of preformed plasma.
Sakaki, Hironao; Nishiuchi, Mamiko; Hori, Toshihiko; Bolton, P.; Yogo, Akifumi; Ogura, Koichi; Sagisaka, Akito; Pirozhkov, A. S.; Orimo, Satoshi; Kondo, Kiminori; et al.
Proceedings of 7th Annual Meeting of Particle Accelerator Society of Japan (DVD-ROM), p.312 - 315, 2010/08
The beam transport test is carried out through the test beam line of the laser-driven proton accelerator which consists of the phase rotation cavity, PMQ, and bending magnet. The laser system used is J-KAREN at JAEA. The final transmitted bunch duration and transverse profile are well predicted by the PARMILA particle transport code by assuming relatively low initial current of the proton beam. The most probable explanation for this is the space charge neutralization by the laser-plasma-electrons.
Nishiuchi, Mamiko; Sakaki, Hironao; Hori, Toshihiko; Bolton, P.; Ogura, Koichi; Sagisaka, Akito; Yogo, Akifumi; Mori, Michiaki; Orimo, Satoshi; Pirozhkov, A. S.; et al.
Physical Review Special Topics; Accelerators and Beams, 13(7), p.071304_1 - 071304_7, 2010/07
Times Cited Count:25 Percentile:79.49(Physics, Nuclear)A laser-driven repetition-rated 1.9 MeV proton beam line composed of permanent quadrupole magnets (PMQs), a radio frequency (rf) phase rotation cavity, and a tunable monochromator is developed to evaluate and to test the simulation of laser-accelerated proton beam transport through an integrated system for the first time. In addition, the proton spectral modulation and focusing behavior of the rf phase rotationcavity device is monitored with input from a PMQ triplet. In the 1.9 MeV region we observe very weakproton defocusing by the phase rotation cavity. The final transmitted bunch duration and transverse profile are well predicted by the PARMILA particle transport code. The transmitted proton beam duration of 6 ns corresponds to an energy spread near 5% for which the transport efficiency is simulated to be 10%. The predictive capability of PARMILA suggests that it can be useful in the design of future higher energy transport beam lines as part of an integrated laser-driven ion accelerator system.
Kiriyama, Hiromitsu; Mori, Michiaki; Nakai, Yoshiki; Shimomura, Takuya; Sasao, Hajime; Tanaka, Momoko; Ochi, Yoshihiro; Tanoue, Manabu*; Okada, Hajime; Kondo, Shuji; et al.
JAEA-Conf 2010-002, p.18 - 21, 2010/06
We have developed a femtosecond high intensity laser system, which combines both Ti:sapphire chirped-pulse amplification (CPA) and optical parametric chirped-pulse amplification (OPCPA) techniques, that produces more than 30 J broadband output energy, indicating the potential for achieving peak powers in excess of 500 TW. With a cleaned high-energy seeded OPCPA preamplifier as a front-end in the system, for the final compressed pulse (without pumping the booster amplifier) we found that the temporal contrast in this system exceeds 10 on the sub-nanosecond timescale, and is near 10 on the nanosecond timescale before the main femtosecond pulse. Using diffractive optical elements for beam homogenization of 100-J level high-energy Nd:glass green pump laser in a Ti:sapphire final amplifier, we have successfully generated broadband high-energy output with near-perfect top-hat intensity distributions.
Kiriyama, Hiromitsu; Mori, Michiaki; Nakai, Yoshiki; Shimomura, Takuya; Sasao, Hajime; Tanoue, Manabu*; Kanazawa, Shuhei; Wakai, Daisuke*; Sasao, Fumitaka*; Okada, Hajime; et al.
Optics Letters, 35(10), p.1497 - 1499, 2010/05
Times Cited Count:85 Percentile:95.22(Optics)OPCPA (Optical parametric chirped-pulse amplification) operation with low gain by seeding with high energy, clean pulses is shown to significantly improve the contrast to better than - in a high intensity Ti:sapphire laser system that is based on chirped pulse amplification. In addition to the high contrast broadband high energy output from the final amplifier is achieved with a flat-topped spatial profile of filling factor near 77%. This is the result of pump beam spatial profile homogenization with diffractive optical elements. Final pulse energies exceed 30-Joules indicating capability for reaching peak powers in excess of 500-TW.
Nishiuchi, Mamiko; Sakaki, Hironao; Hori, Toshihiko; Bolton, P.; Ogura, Koichi; Sagisaka, Akito; Yogo, Akifumi; Mori, Michiaki; Orimo, Satoshi; Pirozhkov, A. S.; et al.
Proceedings of 1st International Particle Accelerator Conference (IPAC '10) (Internet), p.88 - 90, 2010/05
The concept of a compact ion particle accelerator has become attractive in view of recent progress in laser-driven ion acceleration. We report here the recent progress in the laser-driven proton beam transport at the Photo Medical Research Center (PMRC) at JAEA, which is established to address the challenge of laser-driven ion accelerator development for ion beam cancer therapy.
Kiriyama, Hiromitsu; Mori, Michiaki; Nakai, Yoshiki; Shimomura, Takuya; Sasao, Hajime; Tanaka, Momoko; Ochi, Yoshihiro; Tanoue, Manabu*; Okada, Hajime; Kondo, Shuji; et al.
Applied Optics, 49(11), p.2105 - 2115, 2010/04
Times Cited Count:39 Percentile:83.8(Optics)We have developed a femtosecond high intensity laser system, which combines both Ti:sapphire chirped-pulse amplification (CPA) and optical parametric chirped-pulse amplification (OPCPA) techniques, that produces more than 30-J broadband output energy, indicating the potential for achieving peak powers in excess of 500-TW. With a cleaned high-energy seeded OPCPA preamplifier as a front-end in the system, for the compressed pulse without pumping the final amplifier we found that the temporal contrast in this system exceeds 10 on the sub-nanosecond timescales, and is near 10 on the nanosecond timescale prior to the peak of the main femtosecond pulse. Using diffractive optical elements for beam homogenization of 100-J level high-energy Nd:glass green pump laser in a Ti:sapphire final amplifier, we have successfully generated broadband high-energy output with a near-perfect top-hat-like intensity distribution.