Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Uesaka, Takahiro; Kozawa, Masachiyo; Matsumoto, Junko; Endo, Masayuki; Kinoshita, Junichi; Suzuki, Takeshi; Suzuki, Hisao; Morishita, Satoru; Sakamoto, Yu
JAEA-Technology 2012-015, 29 Pages, 2012/06
In Japan Atomic Energy Agency Nuclear Science Research Institute waste treatment building No.2 treat intermediate-level solid waste. Solid wastes are reduced in volume by compaction. They are then canned in stainless can, which are subsequently put in 200-liter concrete-lined drums or 1-m concrete containers, filled with concrete. To prepare for disposal in future, be able to make fit with the technical standard of waste package, we were asked to change the lid type shielded container. Therefore due to the change of lid type shielded container, we confirmed integrity of it with evaluation of close volt by drop analysis, evaluation of shielding, and drop test with a prototype model.
Kondo, Masaaki; Kimishima, Satoru*; Emori, Koichi; Sekita, Kenji; Furusawa, Takayuki; Hayakawa, Masato; Kozawa, Takayuki; Aono, Tetsuya; Kuroha, Misao; Ouchi, Hiroshi
JAEA-Technology 2008-062, 46 Pages, 2008/10
The reactor containment of HTTR is tested to confirm leak-tight integrity of itself. "Type A test" has been conducted in accordance with the standard testing method in JEAC4203 since the preoperational verification of the containment was made. Type A tests are identified as basic one for measuring containment leakage rate, it costs much, however. Therefore, the test program for HTTR was revised to adopt an efficient and economical alternatives including "Type B and Type C tests". In JEAC4203-2004, following requirements are specified for adopting alternatives: upward trend of leakage rate by Type A test due to aging should not be recognized; criterion of combined leakage rate with Type B and Type C tests should be established; the criteria for Type A test and combined leakage rate test should be satisfied; correlation between the leakage rates by Type A test and combined leakage rate test should be recognized. Considering the performances of the tests, the policies of corresponding to the requirements were developed, which were accepted by the regulatory agency. This report presents an outline of the tests, identifies issues on the conventional test and summarizes the policies of corresponding to the requirements and of implementing the tests based on the revised program.
Ichimura, Makoto*; Higaki, Hiroyuki*; Kakimoto, Shingo*; Yamaguchi, Yusuke*; Nemoto, Kenju*; Katano, Makoto*; Kozawa, Isao*; Muro, Taishi*; Ishikawa, Masao; Moriyama, Shinichi; et al.
Fusion Science and Technology, 51(2T), p.150 - 153, 2007/02
Times Cited Count:1 Percentile:11.53(Nuclear Science & Technology)In magnetically confined plasmas, fluctuations in the ion cyclotron range of frequency (ICRF) will be driven by the presence of non-thermal ion energy distribution. In strong ICRF heating experiments on the GAMMA 10 tandem mirror, plasmas with a strong temperature anisotropy have been formed. Alfven-ion-cyclotron (AIC) modes are spontaneously excited due to strong temperature anisotropy. High-energy ions are trapped in the local mirror and will form the velocity distribution with the strong anisotropy. To study the relation among the AIC modes, ICEs and beam-driven electrostatic instabilities with non-thermal energy distribution is the main purpose of this work. When the NBs are injected, the magnetic fluctuations due to injected beams and FP ions are detected by ICRF antennas used as pickup loops on JT-60U. The wave excitation near ion cyclotron and its higer harmonic frequencies are studied experimentally and theoretically in plasmas with non-thermal ion energy distribution.
Ichimura, Makoto*; Higaki, Hiroyuki*; Yamaguchi, Yusuke*; Nemoto, Tatsuki*; Katano, Makoto*; Motegi, Yukimi*; Kozawa, Isao*; Muro, Taishi*; Ishikawa, Masao; Moriyama, Shinichi; et al.
no journal, ,
The wave excitation in the ion cyclotron range of frequency (ICRF) is strongly affected by the boundary conditions. The formation of eigenmodes depends on the plasma parameters, their spatial profiles, the magnetic field profile and so on. The main subject of this presentation is the establishment of plasma diagnostics with ICRF waves. In GAMMA 10, the injection of low power ICRF waves into the plasma as active diagnostics has been tested. The preliminary results are reported. In JT-60U, the ion cyclotron emissions (ICEs) due to high energy ions from the neutral beam injections and the fusion reactions have been clearly observed. The frequency spectra of ICEs also depend on the plasma parameters. ICEs for passive diagnostic tools are discussed.
Aoki, Isao; Asazuma, Shinichiro; Sudo, Tomoyuki; Komiya, Tomokazu; Nakamura, Masahiko; Uchida, Shinichi; Kozawa, Masachiyo; Sonoda, Takashi; Mikake, Shinichiro; Ikeda, Koki; et al.
no journal, ,
JAEAs technical experiences and lessons learned for environmental remediationof Fukushima. (Technical supports for local governments)