How different is the core of $$^{25}$$F from $$^{24}$$O$$_{g.s.}$$ ?

Tang, T. L.*; Uesaka, Tomohiro*; Kawase, Shoichiro; Beaumel, D.*; Dozono, Masanori*; Fujii, Toshihiko*; Fukuda, Naoki*; Fukunaga, Taku*; Galindo-Uribarri, A.*; Hwang, S. H.*; et al.

Physical Review Letters, 124(21), p.212502_1 - 212502_6, 2020/05

 Times Cited Count:14 Percentile:74.18(Physics, Multidisciplinary)

The structure of a neutron-rich $$^{25}$$F nucleus is investigated by a quasifree ($$p,2p$$) knockout reaction. The sum of spectroscopic factors of $$pi 0d_{5/2}$$ orbital is found to be 1.0 $$pm$$ 0.3. The result shows that the $$^{24}$$O core of $$^{25}$$F nucleus significantly differs from a free $$^{24}$$O nucleus, and the core consists of $$sim$$35% $$^{24}$$O$$_{rm g.s.}$$, and $$sim$$65% excited $$^{24}$$O. The result shows that the $$^{24}$$O core of $$^{25}$$F nucleus significantly differs from a free $$^{24}$$O nucleus. The result may infer that the addition of the $$0d_{5/2}$$ proton considerably changes the neutron structure in $$^{25}$$F from that in $$^{24}$$O, which could be a possible mechanism responsible for the oxygen dripline anomaly.

Journal Articles

Repeatability and reproducibility of measurements of low dissolved radiocesium concentrations in freshwater using different pre-concentration methods

Kurihara, Momo*; Yasutaka, Tetsuo*; Aono, Tatsuo*; Ashikawa, Nobuo*; Ebina, Hiroyuki*; Iijima, Takeshi*; Ishimaru, Kei*; Kanai, Ramon*; Karube, Jinichi*; Konnai, Yae*; et al.

Journal of Radioanalytical and Nuclear Chemistry, 322(2), p.477 - 485, 2019/11

 Times Cited Count:2 Percentile:21.58(Chemistry, Analytical)

We assessed the repeatability and reproducibility of methods for determining low dissolved radiocesium concentrations in freshwater in Fukushima. Twenty-one laboratories pre-concentrated three of 10 L samples by five different pre-concentration methods (prussian-blue-impregnated filter cartridges, coprecipitation with ammonium phosphomolybdate, evaporation, solid-phase extraction disks, and ion-exchange resin columns), and activity of radiocesium was measured. The z-scores for all of the $$^{137}$$Cs results were within $$pm$$2, indicating that the methods were accurate. The relative standard deviations (RSDs) indicating the variability in the results from different laboratories were larger than the RSDs indicating the variability in the results from each separate laboratory.

Journal Articles

Beam position monitor and its calibration in J-PARC LINAC

Sato, Susumu; Tomisawa, Tetsuo; Sako, Hiroyuki; Shen, G.; Ueno, Akira; Akikawa, Hisashi*; Igarashi, Zenei*; Lee, S.*; Ikegami, Masanori*; Kamikubota, Norihiko*

Proceedings of 2007 Particle Accelerator Conference (PAC '07) (Internet), p.4072 - 4074, 2007/08

The beam commissioning of J-PARC LINAC has been started in November 2006. Beam Position Monitors (BPM's) which had been calibrated on the bench setup with a scanning wire, take beam-based-calibration method in order to enable the beam to pass at the centre of a quadrupole magnet (Q-magnet). The installed BPM's and their calibration methods are described.

Journal Articles

Upgrade of beam diagnostics in LEBT and MEBT of J-PARC LINAC

Sato, Susumu; Tomisawa, Tetsuo; Kondo, Yasuhiro; Ueno, Akira; Akikawa, Hisashi*; Igarashi, Zenei*; Lee, S.*; Kubota, Chikashi*; Ikegami, Masanori*

Proceedings of 23rd International Linear Accelerator Conference (LINAC 2006) (CD-ROM), p.268 - 270, 2007/00

In the J-PARC LINAC, upgrade of beam diagnostics of LEBT and MEBT is taken. Three beam current monitors and two beam phase monitors are added. In the LEBT and MEBT section, large number of accelerator devices are placed. Therefore to save the space, several modifications are needed, for example, additional monitors need to be welded with each other. Those details of the upgrade of beam diagnostics system are described.

Journal Articles

Developments of the calibration tools for beam position monitor at J-PARC LINAC

Sato, Susumu; Tomisawa, Tetsuo; Akikawa, Hisashi; Ueno, Akira; Lee, S.*; Igarashi, Zenei*; Ikegami, Masanori*; Toyama, Takeshi*; Kamikubota, Norihiko*

Proceedings of 2005 Particle Accelerator Conference (PAC '05) (CD-ROM), p.2777 - 2779, 2005/00

The J-PARC LINAC requires for fine control of beam position to minimize beam loss. So that BPMs need to be calibrated with the accuracy of about a hundred micro-meters. The accuracy of BPMs are calibrated with the calibration tool and real beam. In this paper, details of these developments around BPMs are to be reported.

Journal Articles

Beam commissioning of the J-PARC linac DTL1 at KEK

Kondo, Yasuhiro; Akikawa, Hisashi; Anami, Shozo*; Asano, Hiroyuki*; Fukui, Yuji*; Igarashi, Zenei*; Ikegami, Kiyoshi*; Ikegami, Masanori*; Ito, Takashi; Kawamura, Masato*; et al.

Proceedings of 1st Annual Meeting of Particle Accelerator Society of Japan and 29th Linear Accelerator Meeting in Japan, p.156 - 158, 2004/08

A commissioning of the J-PARC linac DTL1 is now under way at KEK. A 30mA H$$^{-}$$ beam was accelerated to 19.7-MeV, and 100% transmission was obtained with a 20-msec-pulse-width and 12.5-Hz-repetition beam. In this paper, present status of the DTL1 commissioning and preliminary results of the commissioning, such as emittance measurements, are presented.

Journal Articles

Systematic calibration of beam position monitor at J-PARC LINAC

Sato, Susumu; Tomisawa, Tetsuo; Hiroki, Fumio; Lee, S.*; Igarashi, Zenei*; Ikegami, Masanori*; Ueno, Akira; Kondo, Yasuhiro; Hasegawa, Kazuo; Toyama, Takeshi*; et al.

Proceedings of 1st Annual Meeting of Particle Accelerator Society of Japan and 29th Linear Accelerator Meeting in Japan, p.467 - 469, 2004/08

As a joint project of KEK and JAERI, a MW class of high intensity proton accelerator (J-PARC), consisting of Linac, 3 GeV-RCS, 50 GeV-MR, is under construction. For this accelerator, it is required to minimize the beam loss (typically, lower than0.1$$sim$$1 W/m at the linac). To achieve the requirement, beam trajectory needs to be controlled with accuracy of some 100 $$mu$$m. The first stage of the acceleration (up to 181 MeV during the first stage of construction) is done by linac. The beam position monitor (BPM) in the linac utilizes 4 stripline pickups (50 ohm) on the beam transportation chamber. In this paper, systematic calibration of the BPM is described.

Journal Articles

Systematic calibration of beam position monitor in the high intensity proton accelerator (J-PARC) linac

Sato, Susumu; Igarashi, Zenei*; Lee, S.*; Tomisawa, Tetsuo; Hiroki, Fumio; Kishiro, Junichi; Ikegami, Masanori*; Kondo, Yasuhiro; Hasegawa, Kazuo; Ueno, Akira; et al.

Proceedings of 22nd International Linear Accelerator Conference (LINAC 2004), p.429 - 431, 2004/00

As a joint project of KEK and JAERI, a MW class of high intensity proton accelerator (J-PARC), consisting of Linac, 3 GeV-RCS, 50 GeV-MR, is under construction at Tokai, Japan. For this accelerator, it is required to minimize the beam loss (typically, lower than 0.1$$sim$$1 W/m at the linac). To achieve the requirement, beam trajectory needs to be controlled with accuracy of some 100 micro-meter. The first stage of the acceleration (up to 181 MeV during the first stage of construction) is done by linac. The beam position monitor (BPM) in the linac utilizes 4 strip-line pickups (50 ohm) on the beam transportation chamber. In this paper, systematic calibration of the BPM is described.

Journal Articles

Energetic protons from a few-micron metallic foil evaporated by an intense laser pulse

Matsukado, Koji*; Esirkepov, T. Z.; Kinoshita, Kenichi*; Daido, Hiroyuki; Utsumi, Takayuki*; Li, Z.*; Fukumi, Atsushi*; Hayashi, Yukio; Orimo, Satoshi; Nishiuchi, Mamiko; et al.

Physical Review Letters, 91(21), p.215001_1 - 215001_4, 2003/11

 Times Cited Count:136 Percentile:95.25(Physics, Multidisciplinary)

no abstracts in English