Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 51

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Status and upgrade plan of the cERL gun

Nishimori, Nobuyuki; Nagai, Ryoji; Mori, Michiaki; Hajima, Ryoichi; Yamamoto, Masahiro*; Honda, Yosuke*; Miyajima, Tsukasa*; Uchiyama, Takashi*; Jin, X.*; Obina, Takashi*; et al.

Proceedings of 12th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.511 - 515, 2015/09

no abstracts in English

Journal Articles

Development of a high-brightness and high-current electron gun for high-flux $$gamma$$-ray generation

Nishimori, Nobuyuki; Nagai, Ryoji; Matsuba, Shunya; Hajima, Ryoichi; Yamamoto, Masahiro*; Honda, Yosuke*; Miyajima, Tsukasa*; Uchiyama, Takashi*; Kuriki, Masao*

Nuclear Physics and $$gamma$$-ray sources for Nuclear Security and Nonproliferation, p.321 - 326, 2014/12

Journal Articles

Generation of a 500-keV electron beam with milliampere current from a photoemission DC gun

Nishimori, Nobuyuki; Nagai, Ryoji; Matsuba, Shunya; Hajima, Ryoichi; Yamamoto, Masahiro*; Miyajima, Tsukasa*; Honda, Yosuke*; Uchiyama, Takashi*; Iijima, Hokuto*; Kuriki, Masao*; et al.

Proceedings of 10th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.174 - 178, 2014/06

no abstracts in English

Journal Articles

Experimental investigation of an optimum configuration for a high-voltage photoemission gun for operation at $$geq$$ 500 kV

Nishimori, Nobuyuki; Nagai, Ryoji; Matsuba, Shunya; Hajima, Ryoichi; Yamamoto, Masahiro*; Honda, Yosuke*; Miyajima, Tsukasa*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*

Physical Review Special Topics; Accelerators and Beams, 17(5), p.053401_1 - 053401_17, 2014/05

 Times Cited Count:24 Percentile:80.32(Physics, Nuclear)

Journal Articles

Progress in a photocathode DC gun at the compact ERL

Nishimori, Nobuyuki; Nagai, Ryoji; Matsuba, Shunya; Hajima, Ryoichi; Yamamoto, Masahiro*; Honda, Yosuke*; Miyajima, Tsukasa*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*

Proceedings of 35th International Free-Electron Laser Conference (FEL 2013) (Internet), p.184 - 188, 2013/08

Journal Articles

Development of a 500-kV photoemission DC gun at JAEA

Nishimori, Nobuyuki; Nagai, Ryoji; Matsuba, Shunya; Hajima, Ryoichi; Yamamoto, Masahiro*; Miyajima, Tsukasa*; Honda, Yosuke*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*; et al.

Proceedings of 9th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.255 - 259, 2013/08

no abstracts in English

Journal Articles

Generation of a 500-keV electron beam from a high voltage photoemission gun

Nishimori, Nobuyuki; Nagai, Ryoji; Matsuba, Shunya; Hajima, Ryoichi; Yamamoto, Masahiro*; Miyajima, Tsukasa*; Honda, Yosuke*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*

Applied Physics Letters, 102(23), p.234103_1 - 234103_4, 2013/06

 Times Cited Count:20 Percentile:62.30(Physics, Applied)

Journal Articles

Beam generation from a 500 kV DC photoemission electron gun

Nishimori, Nobuyuki; Nagai, Ryoji; Matsuba, Shunya; Hajima, Ryoichi; Yamamoto, Masahiro*; Honda, Yosuke*; Miyajima, Tsukasa*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*

Proceedings of 4th International Particle Accelerator Conference (IPAC '13) (Internet), p.321 - 323, 2013/05

Journal Articles

Development of a photoemission DC Gun at JAEA

Nishimori, Nobuyuki; Nagai, Ryoji; Matsuba, Shunya; Hajima, Ryoichi; Yamamoto, Masahiro*; Honda, Yosuke*; Miyajima, Tsukasa*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*; et al.

Proceedings of 34th International Free Electron Laser Conference (FEL 2012) (Internet), p.161 - 164, 2012/08

Journal Articles

Development of a 500-kV photocathode DC gun

Nishimori, Nobuyuki; Nagai, Ryoji; Hajima, Ryoichi; Yamamoto, Masahiro*; Miyajima, Tsukasa*; Honda, Yosuke*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*; Okumi, Shoji*; et al.

Proceedings of 8th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.20 - 23, 2011/08

no abstracts in English

Journal Articles

Development of a 500-kV photocathode DC gun for ERLs

Nishimori, Nobuyuki; Nagai, Ryoji; Yamamoto, Masahiro*; Honda, Yosuke*; Miyajima, Tsukasa*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*; Okumi, Shoji*; Nakanishi, Tsutomu*; et al.

Journal of Physics; Conference Series, 298, p.012005_1 - 012005_6, 2011/06

Journal Articles

Development of a 500-kV photo-cathode DC gun for ERL light sources

Nishimori, Nobuyuki; Nagai, Ryoji; Hajima, Ryoichi; Yamamoto, Masahiro*; Honda, Yosuke*; Miyajima, Tsukasa*; Muto, Toshiya*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*; et al.

Proceedings of 25th International Linear Accelerator Conference (LINAC 2010) (CD-ROM), p.995 - 997, 2010/09

Journal Articles

Basic vacuum test of 500-kV photocathode DC gun components at KEK

Yamamoto, Masahiro*; Uchiyama, Takashi*; Miyajima, Tsukasa*; Honda, Yosuke*; Sato, Kotaro*; Matsuba, Shunya*; Saito, Yoshio*; Kobayashi, Masanori*; Kurisu, Hiriki*; Hajima, Ryoichi; et al.

Proceedings of 7th Annual Meeting of Particle Accelerator Society of Japan (DVD-ROM), p.717 - 720, 2010/08

A 500-kV photocathode DC electron gun which can supply the beam of a low emittance and a high average current has been developed in collaboration with KEK, JAEA, Hiroshima Univ., Nagoya Univ. and Yamaguchi Univ. The vacuum of the gun chamber has to be lower Extreme High Vacuum for maintain cathode-life time. A titanium chamber and new material of ceramic were employed to reduce outgassing rate. The result of outgassing rate of the gun chamber is described in this report.

Journal Articles

High-voltage test of a 500-KV photocathode DC electron-gun for a next-generation light-source

Nagai, Ryoji; Nishimori, Nobuyuki; Hajima, Ryoichi; Muto, Toshiya*; Yamamoto, Masahiro*; Miyajima, Tsukasa*; Honda, Yosuke*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*; et al.

Proceedings of 7th Annual Meeting of Particle Accelerator Society of Japan (DVD-ROM), p.806 - 808, 2010/08

A 500-kV, 10-mA photocathode DC gun which is designed for next-generation light- sources based on energy-recovery linac has been developed in a collaboration effort of JAEA, KEK, Hiroshima University and Nagoya University. We have utilized a segmented cylindrical ceramic insulator and guard-ring electrodes to prevent any damage to the insulator from electrons emitted by the support-rod electrode. The 500-kV gun was successfully conditioned up to a voltage of 550 kV and a long-time holding test for 8 h was demonstrated at an acceleration voltage of 500 kV. The cathode electrode, anode electrode, and beam line apparatuses are now under fabrication and beam tests of the gun will be started soon.

Journal Articles

Development of a 500-kV photocathode DC gun for ERL light sources

Nishimori, Nobuyuki; Nagai, Ryoji; Hajima, Ryoichi; Yamamoto, Masahiro*; Miyajima, Tsukasa*; Honda, Yosuke*; Muto, Toshiya*; Iijima, Hokuto*; Kuriki, Masao*; Kuwahara, Makoto*; et al.

Proceedings of 7th Annual Meeting of Particle Accelerator Society of Japan (DVD-ROM), p.802 - 805, 2010/08

no abstracts in English

Journal Articles

Development of a photocathode DC electron-gun for next-generation light-sources

Nagai, Ryoji; Hajima, Ryoichi; Nishimori, Nobuyuki; Muto, Toshiya*; Yamamoto, Masahiro*; Honda, Yosuke*; Miyajima, Tsukasa*; Kuriki, Masao*; Iijima, Hokuto*; Kuwahara, Makoto*; et al.

Kasokuki, 7(2), p.88 - 94, 2010/07

A 500-kV, 10-mA photocathode DC gun which is designed for next-generation light-sources based on energy-recovery linac has been developed in a collaboration effort of JAEA, KEK, Hiroshima University and Nagoya University. We have utilized a segmented cylindrical ceramic insulator and guard-ring electrodes to prevent any damage to the insulator from electrons emitted by the support-rod electrode. The 500-kV gun was successfully conditioned up to a voltage of 550 kV and a long-time holding test for 8 h was demonstrated at an acceleration voltage of 500 kV. The 500-kV gun consists of a Cockcroft-Walton generator, a segmented cylindrical ceramic insulator, guard-ring electrodes, a support-rod electrode, a vacuum chamber, and a pressurized insulating gas tank. The cathode electrode, anode electrode, and beam line apparatuses are now under fabrication and beam tests of the gun will be started soon.

Journal Articles

Recent progress in the energy recovery linac project in Japan

Sakanaka, Shogo*; Akemoto, Mitsuo*; Aoto, Tomohiro*; Arakawa, Dai*; Asaoka, Seiji*; Enomoto, Atsushi*; Fukuda, Shigeki*; Furukawa, Kazuro*; Furuya, Takaaki*; Haga, Kaiichi*; et al.

Proceedings of 1st International Particle Accelerator Conference (IPAC '10) (Internet), p.2338 - 2340, 2010/05

Future synchrotron light source using a 5-GeV energy recovery linac (ERL) is under proposal by our Japanese collaboration team, and we are conducting R&D efforts for that. We are developing high-brightness DC photocathode guns, two types of cryomodules for both injector and main superconducting (SC) linacs, and 1.3 GHz high CW-power RF sources. We are also constructing the Compact ERL (cERL) for demonstrating the recirculation of low-emittance, high-current beams using above-mentioned critical technologies.

Journal Articles

High-voltage test of a 500-kV photocathode DC gun for the ERL light sources in Japan

Nagai, Ryoji; Hajima, Ryoichi; Nishimori, Nobuyuki; Muto, Toshiya*; Yamamoto, Masahiro*; Honda, Yosuke*; Miyajima, Tsukasa*; Kuriki, Masao*; Iijima, Hokuto*; Kuwahara, Makoto*; et al.

Proceedings of 1st International Particle Accelerator Conference (IPAC '10) (Internet), p.2341 - 2343, 2010/05

A 500-kV, 10-mA photocathode DC gun has been developed in a collaboration effort of JAEA, KEK, Hiroshima University and Nagoya University. We have utilized a segmented cylindrical ceramic insulator and guard-ring electrodes to prevent any damage to the insulator from electrons emitted by the support-rod electrode. The high-voltage test of the gun has been successfully done with up to 550 kV. The cathode electrode, anode electrode, and beam line apparatuses are now under fabrication. A beam test of the gun will be started soon. The high-voltage test and up-to-date status of the gun development will be presented in detail.

Journal Articles

Development of a photocathode preparation system and a high voltage chamber for a 500 kV DC gun for ERL light sources

Nishimori, Nobuyuki; Nagai, Ryoji; Iijima, Hokuto; Hajima, Ryoichi; Yamamoto, Masahiro*; Muto, Toshiya*; Miyajima, Tsukasa*; Honda, Yosuke*; Kuriki, Masao*; Kuwahara, Makoto*; et al.

Proceedings of 6th Annual Meeting of Particle Accelerator Society of Japan (CD-ROM), p.872 - 874, 2010/03

no abstracts in English

Journal Articles

High voltage test of a 500-kV DC electron gun for an ERL light source

Nagai, Ryoji; Hajima, Ryoichi; Nishimori, Nobuyuki; Iijima, Hokuto; Muto, Toshiya*; Honda, Yosuke*; Miyajima, Tsukasa*; Yamamoto, Masahiro*; Kuriki, Masao*; Kuwahara, Makoto*; et al.

Proceedings of 6th Annual Meeting of Particle Accelerator Society of Japan (CD-ROM), p.863 - 865, 2010/03

A 500-kV, 10-mA photocathode DC gun has been designed and is now under fabrication by the collaboration efforts of JAEA, KEK, Hiroshima University and Nagoya University. We have adopted a multiple-stacked cylindrical ceramic insulator, because this type of ceramic insulator has shown good stability and robustness at the 250-kV JAEA FEL gun and the 200-kV Nagoya polarized gun. The Cockcroft-Walton voltage multiplier, the ceramic insulator, the vacuum chambers has been fabricated and a high-voltage test will be successfully achieved soon. Up-to-date status of the gun development is presented in detail.

51 (Records 1-20 displayed on this page)