Refine your search:     
Report No.
 - 
Search Results: Records 1-9 displayed on this page of 9
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Tungsten impurity density in fusion plasma

Nakano, Tomohide; Shumack, A.*; Maggi, C. F.*

Journal of Physics B; Atomic, Molecular and Optical Physics, 2 Pages, 2016/01

Collaboration of researchers from Japan Atomic Energy Agency and EUROfusion Consortium (Dutch Institute For Fundamental Energy Research, Max-Planck-Institut f$"{u}$r Plasmaphysik and so on) successfully led to determination of tungsten ion density in high temperature plasmas in Joint European Torus (JET) with an upgraded X-ray spectrometer. The researchers used the FAC code and successfully identified $$mbox{W}^{45+}$$, $$mbox{W}^{46+}$$ and $$mbox{Mo}^{32+}$$ spectral lines. The $$mbox{Mo}^{32+}$$ line identification was confirmed experimentally by Mo injection to the plasma. From the measured absolute intensity of these spectral lines, tungsten and molybdenum ion densities in the plasma core were determined.

Journal Articles

Determination of tungsten and molybdenum concentrations from an X-ray range spectrum in JET with the ITER-like wall configuration

Nakano, Tomohide; Shumack, A.*; Maggi, C. F.*; Reinke, M.*; Lawson, K.*; Coffey, I.*; P$"u$tterich, T.*; Brezinsek, S.*; Lipschultz, B.*; Matthews, G. F.*; et al.

Journal of Physics B; Atomic, Molecular and Optical Physics, 48(14), p.144023_1 - 144023_11, 2015/07

 Times Cited Count:29 Percentile:82.31(Optics)

The $$mbox{W}^{45+}$$ and $$mbox{W}^{46+}$$ 3p-4d inner shell excitation lines in addition to $$mbox{Mo}^{32+}$$ 2p-3s lines have been identified from the spectrum taken by an upgraded high-resolution X-ray spectrometer. It is found from analysis of the absolute intensities of the $$mbox{W}^{46+}$$ and $$mbox{Mo}^{32+}$$ lines that W and Mo concentrations are in the range of $$sim10^{-5}$$ and $$sim10^{-6}$$, respectively, with a ratio of $$sim$$ 5% for ELMy H-mode plasmas with a plasma current of 2.0- 2.5 MA, a toroidal magnetic field of 2.7 T and a neutral beam injection power of 14-18 MW. For the purpose of checking self-consistency, it is confirmed that the W concentration determined from the $$mbox{W}^{45+}$$ line is in agreement with that from the $$mbox{W}^{46+}$$ line within 20% and that the plasma effective charge determined from the continuum of the first order reflection spectrum is also in agreement with that from the second order within 50%. Further, the determined plasma effective charge is in agreement with that determined from a visible spectroscopy, confirming that the sensitivity of the X-ray spectrometer is valid and that probably the W and the Mo concentrations are also valid.

Journal Articles

Pedestal stability comparison and ITER pedestal prediction

Snyder, P. B.*; Aiba, Nobuyuki; Beurskens, M.*; Groebner, R. J.*; Horton, L. D.*; Hubbard, A. E.*; Hughes, J. W.*; Huysmans, G. T. A.*; Kamada, Yutaka; Kirk, A.*; et al.

Nuclear Fusion, 49(8), p.085035_1 - 085035_8, 2009/08

 Times Cited Count:170 Percentile:98.64(Physics, Fluids & Plasmas)

The pressure at the top of the edge transport barrier impacts fusion performance, while large ELMs can constrain material lifetimes. Investigation of intermediate wavelength MHD mode has led to improved understanding of the pedestal height and the mechanism for ELMs. The combination of high resolution diagnostics and a suite of stability codes has made edge stability analysis routine, and contribute both to understanding, and to experimental planning and performance optimization. Here we present extensive comparisons of observations to predicted edge stability boundaries on several tokamaks, both for the standard (Type I) ELM regime, and for small ELM and ELM-free regimes. We further discuss a new predictive model for the pedestal height and width (EPED1), developed by self-consistently combining a simple width model with peeling-ballooning stability calculations. This model is tested against experimental measurements, and used in initial predictions of the pedestal height for ITER.

Journal Articles

Pedestal stability comparison and ITER pedestal prediction

Snyder, P. B.*; Aiba, Nobuyuki; Beurskens, M.*; Groebner, R. J.*; Horton, L. D.*; Hubbard, A. E.*; Hughes, J. W.*; Huysmans, G. T. A.*; Kamada, Yutaka; Kirk, A.*; et al.

Proceedings of 22nd IAEA Fusion Energy Conference (FEC 2008) (CD-ROM), 8 Pages, 2008/10

Investigation of intermediate wavelength MHD modes has led to improved understanding of important constraints on the pedestal height and the mechanism for ELMs. The combination of high resolution pedestal diagnostics and a suite of highly efficient stability codes, has made edge stability analysis routine on several major tokamaks, contributing both to understanding, and to experimental planning and performance optimization. Here we present extensive comparisons of observations to predicted edge stability boundaries on several tokamaks, both for the standard ELM regime, and for small ELM and ELM-free regimes. We further use the stability constraint on pedestal height to test models of the pedestal width, and self-consistently combine a simple width model with MHD stability calculations to develop a new predictive model (EPED1) for the pedestal height and width. This model is tested against experimental measurements, and used in initial predictions of the pedestal height for ITER.

Journal Articles

Characteristics of the H-mode pedestal in improved confinement scenarios in ASDEX Upgrade, DIII-D, JET and JT-60U

Maggi, C. F.*; Groebner, R. J.*; Oyama, Naoyuki; Sartori, R.*; Horton, L. D.*; Sips, A. C. C.*; Suttrop, W.*; ASDEX Upgrade Team; Leonard, A.*; Luce, T. C.*; et al.

Nuclear Fusion, 47(7), p.535 - 551, 2007/07

 Times Cited Count:63 Percentile:88.45(Physics, Fluids & Plasmas)

Pedestal and global plasma parameters are compared in ELMy H-modes and improved confinement discharges from ASDEX Upgrade (AUG), DIII-D, JET and JT-60U with varying net input power. The pedestal top pressure increases moderately with power, in broad agreement with the power dependence of the H98(y,2) scaling. For all machines and all scenarios a robust correlation between the total and the pedestal thermal stored energy is observed. In AUG the improved confinement is due to improved pedestal confinement in improved H-modes with early heating and to both improved pedestal and core confinement in improved H-modes with late heating. In DIII-D the increase in confinement is due to improved confinement in the plasma core. JT-60U reversed shear H-modes have strong internal transport barriers and thus improved core performance. In all four tokamaks improved edge stability is correlated with increasing total $$beta_{p}$$ and H98(y,2) increases with pedestal $$beta_{p}$$.

Journal Articles

Edge pedestal physics and its implications for ITER

Kamada, Yutaka; Leonard, A. W.*; Bateman, G.*; Becoulet, M.*; Chang, C. S.*; Eich, T.*; Evans, T. E.*; Groebner, R. J.*; Guzdar, P. N.*; Horton, L. D.*; et al.

Proceedings of 21st IAEA Fusion Energy Conference (FEC 2006) (CD-ROM), 8 Pages, 2007/03

no abstracts in English

Journal Articles

Characteristics of the H-mode pedestal in improved confinement scenarios in ASDEX Upgrade, DIII-D, JET and JT-60U

Maggi, C. F.*; Groebner, R. J.*; Oyama, Naoyuki; Sartori, R.*; Horton, L. D.*; Sips, A. C. C.*; Suttrop, W.*; ASDEX Upgrade Team; Leonard, T.*; Luce, T. C.*; et al.

Proceedings of 21st IAEA Fusion Energy Conference (FEC 2006) (CD-ROM), 8 Pages, 2007/03

Pedestal and global plasma parameters are compared in ELMy H-mode discharges from ASDEX Upgrade (AUG), DIII-D, JET and JT-60U. The increase in pedestal pressure (p$$^{PED}$$) with power is continuous, reflecting the continuous transition from "standard H-mode" to "improved confinement scenario". In AUG improved H-modes p$$^{PED}$$ increases with power due to an increase of both pedestal top density and temperature. In DIII-D p$$^{PED}$$ increases primarily due to an increase of the pedestal temperature. In JT-60U high $$beta_{pol}$$ H-modes at $$q_{95}$$ = 6.5 and high $$delta$$ the improved confinement is due to an increase of $$W_{PED}$$, while in reversed shear H-modes to an increase of $$W_{core}$$. In JET hybrid discharges at 1.4 MA $$W_{th}$$ increases with power and $$delta$$ due to an increase of $$W_{PED}$$. In all four tokamaks improved edge stability is correlated to increasing total $$beta_{pol} $$ and H98(y,2) increases with pedestal $$beta_{pol}$$.

Journal Articles

D$$_{alpha}$$ measurements in the JET divertor with the divertor periscope diagnostic

Loarer, T.*; Horton, L. D.*; Kubo, Hirotaka; Maggi, C. F.*; Morgen, P. D.*; Stamp, M. F.*; Von Hellermann, M.*

JET-R-99-05, p.1 - 20, 1999/09

no abstracts in English

Oral presentation

Determination of tungsten and molybdenum concentrations from an X-ray range spectrum in JET

Nakano, Tomohide; Shumack, A.*; Maggi, C. F.*; Reinke, M.*; Lawson, K.*; P$"u$tterich, T.*; Brezinsek, S.*; Lipschultz, B.*; Matthews, G. F.*; Chernyshova, M.*; et al.

no journal, , 

In an European tokamak device, JET, an existing high-resolution X-ray crystal spectrometer was upgraded together with installation of the W divertor for the purpose of monitoring the W density in the core plasma. We have identified W$$^{46+}$$, W$$^{45+}$$ and Mo$$^{32+}$$ lines by comparing the spectrum observed by this spectrometer and that calculated by an atomic structure code. Further, from the intensities of these spectral lines, the W density and the Mo density over an electron density were determined to be $$10^{-5}$$ and $$10^{-7}$$, respectively. The determined W density was in good agreement with that from another spectrometer. In addition, the plasma effective charge evaluated from the continuum intensity observed by the X-ray spectrometer was in agreement with that from a visible spectrometer within a factor of three. From these agreements, it is probable that the determined W and Mo density are valid. In contrast, the determined W density is only 15% compared with that from an soft X-ray array measurement. This inconsistency will be investigated in the near future.

9 (Records 1-9 displayed on this page)
  • 1