Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 20
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Radon measurements with a compact, organic-scintillator-based alpha/beta spectrometer

Morishita, Yuki; Ye, Y.*; Mata, L.*; Pozzi, S. A.*; Kearfott, K. J.*

Radiation Measurements, 137, p.106428_1 - 106428_7, 2020/09

 Times Cited Count:8 Percentile:60.71(Nuclear Science & Technology)

We have developed a compact, organic-scintillator-based alpha/beta spectrometer for radon measurements and have characterized it using a unique, small radon chamber. The spectrometer is composed of a through-silicon via (TSV) silicon photomultiplier (or SiPM) and a 6 mm $$times$$ 6 mm $$times$$ 6 mm stilbene crystal cube. Analog signals from the SiPM are sent to a digitizer. The detector is housed in a light-tight box, with a stacked air filter installed in one side of the box to enable $$^{222}$$Rn gas to diffuse to the inside. We conducted one experiment with the spectrometer and an AlphaGUARD detector placed in a basement at the University of Michigan, and we conducted other experiments with both detectors placed in a small radon chamber together with $$^{226}$$Ra sources. By applying a pulse-shape-discrimination technique, we were able to separate the alpha and beta spectra simultaneously and clearly and to measure them quantitatively. We found two peaks in the measured alpha spectrum: a lower-energy peak due to $$^{218}$$Po and a higher-energy peak due to $$^{214}$$Po. We found a linear relation between the radon concentration y from AlphaGUARD and the counting rates from the stilbene-SiPM detector. The alpha/beta spectrometer is less than 10 mm thick, and we expect that it will be easy to increase the sensitivity with future device construction. Thus, this compact, organic-scintillator-based alpha/beta spectrometer shows promise for use in novel radon-detection systems.

Journal Articles

Reference design of the power supply system for the resistive-wall-mode control in JT-60SA

Ferro, A.*; Gaio, E.*; Novello, L.*; Matsukawa, Makoto; Shimada, Katsuhiro; Kawamata, Yoichi; Takechi, Manabu

Fusion Engineering and Design, 98-99, p.1053 - 1057, 2015/10

 Times Cited Count:3 Percentile:25.85(Nuclear Science & Technology)

Journal Articles

22A beam production of the uniform negative ions in the JT-60 negative ion source

Yoshida, Masafumi; Hanada, Masaya; Kojima, Atsushi; Kashiwagi, Mieko; Grisham, L. R.*; Hatayama, Akiyoshi*; Shibata, Takanori*; Yamamoto, Takashi*; Akino, Noboru; Endo, Yasuei; et al.

Fusion Engineering and Design, 96-97, p.616 - 619, 2015/10

 Times Cited Count:11 Percentile:67.3(Nuclear Science & Technology)

In JT-60 Super Advanced for the fusion experiment, 22A, 100s negative ions are designed to be extracted from the world largest ion extraction area of 450 mm $$times$$ 1100 mm. One of the key issues for producing such as high current beams is to improve non-uniform production of the negative ions. In order to improve the uniformity of the negative ions, a tent-shaped magnetic filter has newly been developed and tested for JT-60SA negative ion source. The original tent-shaped filter significantly improved the logitudunal uniformity of the extracted H$$^{-}$$ ion beams. The logitudinal uniform areas within a $$pm$$10 deviation of the beam intensity were improved from 45% to 70% of the ion extraction area. However, this improvement degrades a horizontal uniformity. For this, the uniform areas was no more than 55% of the total ion extraction area. In order to improve the horizontal uniformity, the filter strength has been reduced from 660 Gasus$$cdot$$cm to 400 Gasus$$cdot$$cm. This reduction improved the horizontal uniform area from 75% to 90% without degrading the logitudinal uniformity. This resulted in the improvement of the uniform area from 45% of the total ion extraction areas. This improvement of the uniform area leads to the production of a 22A H$$^{-}$$ ion beam from 450 mm $$times$$ 1100 mm with a small amount increase of electron current of 10%. The obtained beam current fulfills the requirement for JT-60SA.

Journal Articles

Progress in long-pulse production of powerful negative ion beams for JT-60SA and ITER

Kojima, Atsushi; Umeda, Naotaka; Hanada, Masaya; Yoshida, Masafumi; Kashiwagi, Mieko; Tobari, Hiroyuki; Watanabe, Kazuhiro; Akino, Noboru; Komata, Masao; Mogaki, Kazuhiko; et al.

Nuclear Fusion, 55(6), p.063006_1 - 063006_9, 2015/06

 Times Cited Count:41 Percentile:89.45(Physics, Fluids & Plasmas)

Significant progresses in the extension of pulse durations of powerful negative ion beams have been made to realize the neutral beam injectors for JT-60SA and ITER. In order to overcome common issues of the long pulse production/acceleration of negative ion beams in JT-60SA and ITER, the new technologies have been developed in the JT-60SA ion source and the MeV accelerator in Japan Atomic Energy Agency. As for the long pulse production of high-current negative ions for JT-60SA ion source, the pulse durations have been successfully increased from 30 s at 13 A on JT-60U to 100 s at 15 A by modifying the JT-60SA ion source, which satisfies the required pulse duration of 100 s and 70% of the rated beam current for JT-60SA. This progress was based on the R&D efforts for the temperature control of the plasma grid and uniform negative ion productions with the modified tent-shaped filter field configuration. Moreover, the each parameter of the required beam energy, current and pulse has been achieved individually by these R&D efforts. The developed techniques are useful to design the ITER ion source because the sustainment of the cesium coverage in large extraction area is one of the common issues between JT-60SA and ITER. As for the long pulse acceleration of high power density beams in the MeV accelerator for ITER, the pulse duration of MeV-class negative ion beams has been extended by more than 2 orders of magnitude by modifying the extraction grid with a high cooling capability and a high-transmission of negative ions. A long pulse acceleration of 60 s has been achieved at 70 MW/m$$^{2}$$ (683 keV, 100 A/m$$^{2}$$) which has reached to the power density of JT-60SA level of 65 MW/m$$^{2}$$.

Journal Articles

Improvement of uniformity of the negative ion beams by Tent-shaped magnetic field in the JT-60 negative ion source

Yoshida, Masafumi; Hanada, Masaya; Kojima, Atsushi; Kashiwagi, Mieko; Grisham, L. R.*; Akino, Noboru; Endo, Yasuei; Komata, Masao; Mogaki, Kazuhiko; Nemoto, Shuji; et al.

Review of Scientific Instruments, 85(2), p.02B314_1 - 02B314_4, 2014/02

 Times Cited Count:14 Percentile:50.88(Instruments & Instrumentation)

Non-uniformity of the negative ion beams in the JT-60 negative ion source was improved by modifying an external magnetic field to a tent-shaped magnetic field for reduction of the local heat loads in the source. Distributions of the source plasmas (H$$^{+}$$ ions and H$$^{0}$$ atoms) of the parents of H$$^{-}$$ ions converted on the cesium covered plasma grids were measured by Langmuir probes and emission spectroscopy. Beam intensities of the H$$^{-}$$ ions extracted from the plasma grids were measured by IR camera from the back of the beam target plate. The tent-shaped magnetic field prevented the source plasmas to be localized by B $$times$$ grad B drift of the primary electrons emitted from the filaments in the arc chamber. As a result, standard derivation of the H$$^{-}$$ ions beams was reduced from 14% (the external magnetic field) to 10% (the tent-shaped magnetic field) without reduction of an activity of the H$$^{-}$$ ion production.

Journal Articles

Origin of non-uniformity of the source plasmas in JT-60 negative ion source

Yoshida, Masafumi; Hanada, Masaya; Kojima, Atsushi; Inoue, Takashi; Kashiwagi, Mieko; Grisham, L. R.*; Akino, Noboru; Endo, Yasuei; Komata, Masao; Mogaki, Kazuhiko; et al.

Plasma and Fusion Research (Internet), 8(Sp.1), p.2405146_1 - 2405146_4, 2013/11

Distributions of H$$^{0}$$ and H$$^{+}$$ in the source plasmas produced at the end-plugs of JT-60 negative ions source were measured by Langmuir probes and emission spectroscopy in order to experimentally investigate the cause of lower density of the negative ions extracted from end-plugs in the source. Densities of H$$^{0}$$ and H$$^{+}$$ in end-plugs of the plasma grid in the source were compared with those in the center regions. As a result, lower density of the negative ion at the edge was caused by lower beam optics due to lower and higher density of the H$$^{0}$$ and H$$^{+}$$.

Journal Articles

Progress in development and design of the neutral beam injector for JT-60SA

Hanada, Masaya; Kojima, Atsushi; Tanaka, Yutaka; Inoue, Takashi; Watanabe, Kazuhiro; Taniguchi, Masaki; Kashiwagi, Mieko; Tobari, Hiroyuki; Umeda, Naotaka; Akino, Noboru; et al.

Fusion Engineering and Design, 86(6-8), p.835 - 838, 2011/10

 Times Cited Count:13 Percentile:69.64(Nuclear Science & Technology)

Neutral beam (NB) injectors for JT-60 Super Advanced (JT-60SA) have been designed and developed. Twelve positive-ion-based and one negative-ion-based NB injectors are allocated to inject 30 MW D$$^{0}$$ beams in total for 100 s. Each of the positive-ion-based NB injector is designed to inject 1.7 MW for 100s at 85 keV. A part of the power supplies and magnetic shield utilized on JT-60U are upgraded and reused on JT-60SA. To realize the negative-ion-based NB injector for JT-60SA where the injection of 500 keV, 10 MW D$$^{0}$$ beams for 100s is required, R&Ds of the negative ion source have been carried out. High-energy negative ion beams of 490-500 keV have been successfully produced at a beam current of 1-2.8 A through 20% of the total ion extraction area, by improving voltage holding capability of the ion source. This is the first demonstration of a high-current negative ion acceleration of $$>$$1 A to 500 keV. The design of the power supplies and the beamline is also in progress. The procurement of the acceleration power supply starts in 2010.

Journal Articles

Development of the JT-60SA Neutral Beam Injectors

Hanada, Masaya; Kojima, Atsushi; Inoue, Takashi; Watanabe, Kazuhiro; Taniguchi, Masaki; Kashiwagi, Mieko; Tobari, Hiroyuki; Umeda, Naotaka; Akino, Noboru; Kazawa, Minoru; et al.

AIP Conference Proceedings 1390, p.536 - 544, 2011/09

 Times Cited Count:7 Percentile:84.66(Physics, Atomic, Molecular & Chemical)

no abstracts in English

Journal Articles

Achievement of 500 keV negative ion beam acceleration on JT-60U negative-ion-based neutral beam injector

Kojima, Atsushi; Hanada, Masaya; Tanaka, Yutaka*; Kawai, Mikito*; Akino, Noboru; Kazawa, Minoru; Komata, Masao; Mogaki, Kazuhiko; Usui, Katsutomi; Sasaki, Shunichi; et al.

Nuclear Fusion, 51(8), p.083049_1 - 083049_8, 2011/08

 Times Cited Count:51 Percentile:88.4(Physics, Fluids & Plasmas)

Hydrogen negative ion beams of 490 keV, 3 A and 510 keV, 1 A have been successfully produced in the JT-60 negative ion source with three acceleration stages. These successful productions of the high-energy beams at high current have been achieved by overcoming the most critical issue, i.e., a poor voltage holding of the large negative ion sources with the grids of 2 m$$^{2}$$ for JT-60SA and ITER. To improve voltage holding capability, the breakdown voltages for the large grids was examined for the first time. It was found that a vacuum insulation distance for the large grids was 6-7 times longer than that for the small-area grid (0.02 m$$^{2}$$). From this result, the gap lengths between the grids were tuned in the JT-60 negative ion source. The modification of the ion source also realized a significant stabilization of voltage holding and a short conditioning time. These results suggest a practical use of the large negative ion sources in JT-60SA and ITER.

Journal Articles

Demonstration of 500 keV beam acceleration on JT-60 negative-ion-based neutral beam injector

Kojima, Atsushi; Hanada, Masaya; Tanaka, Yutaka*; Kawai, Mikito*; Akino, Noboru; Kazawa, Minoru; Komata, Masao; Mogaki, Kazuhiko; Usui, Katsutomi; Sasaki, Shunichi; et al.

Proceedings of 23rd IAEA Fusion Energy Conference (FEC 2010) (CD-ROM), 8 Pages, 2011/03

Hydrogen negative ion beams of 490keV, 3A and 510 keV, 1A have been successfully produced in the JT-60 negative ion source with three acceleration stages. These successful productions of the high-energy beams at high current have been achieved by overcoming the most critical issue, i.e., a poor voltage holding of the large negative ion sources with the grids of $$sim$$ 2 m$$^{2}$$ for JT-60SA and ITER. To improve voltage holding capability, the breakdown voltages for the large grids was examined for the first time. It was found that a vacuum insulation distance for the large grids was 6-7 times longer than that for the small-area grid (0.02 m$$^{2}$$). From this result, the gap lengths between the grids were tuned in the JT-60 negative ion source. The modification of the ion source also realized a significant stabilization of voltage holding and a short conditioning time. These results suggest a practical use of the large negative ion sources in JT-60 SA and ITER.

Journal Articles

Development and design of the negative-ion-based NBI for JT-60 Super Advanced

Hanada, Masaya; Akino, Noboru; Endo, Yasuei; Inoue, Takashi; Kawai, Mikito; Kazawa, Minoru; Kikuchi, Katsumi; Komata, Masao; Kojima, Atsushi; Mogaki, Kazuhiko; et al.

Journal of Plasma and Fusion Research SERIES, Vol.9, p.208 - 213, 2010/08

A large negative ion source with an ion extraction area of 110 cm $$times$$ 45 cm has been developed to produce 500 keV, 22 A D$$^{-}$$ ion beams required for JT-60 Super Advanced. To realize the JT-60SA negative ion source, the JT-60 negative ion source has been modified and tested on the negative-ion-based neutral beam injector on JT-60U. A 500 keV H$$^{-}$$ ion beam has been produced at 3 A without a significant degradation of beam optics. This is the first demonstration of a high energy negative ion acceleration of more than one-ampere to 500 keV in the world. The beam current density of 90 A/m$$^{2}$$ is being increased to meet 130 A/m$$^{2}$$ of the design value for JT-60SA by tuning the operation parameters. A long pulse injection of 30 s has been achieved at a injection D$$^{0}$$ power of 3 MW. The injection energy, defined as the product of the injection time and power, reaches 80 MJ by neutralizing a 340 keV, 27 A D$$^{-}$$ ion beam produced with two negative ion sources.

Journal Articles

Recent R&D activities of negative-ion-based ion source for JT-60SA

Ikeda, Yoshitaka; Hanada, Masaya; Kamada, Masaki; Kobayashi, Kaoru; Umeda, Naotaka; Akino, Noboru; Ebisawa, Noboru; Inoue, Takashi; Honda, Atsushi; Kawai, Mikito; et al.

IEEE Transactions on Plasma Science, 36(4), p.1519 - 1529, 2008/08

 Times Cited Count:12 Percentile:41.25(Physics, Fluids & Plasmas)

The JT-60SA N-NBI system is required to inject 10 MW for 100 s at 500 keV. Three key issues should be solved for the JT-60SA N-NBI ion source. One is to improve the voltage holding capability. Recent R&D tests suggested that the accelerator with a large area of grids may need a high margin in the design of electric field and a long time for conditioning. The second issue is to reduce the grid power loading. It was found that some beamlets were strongly deflected due to beamlet-beamlet interaction and strike on the grounded grid. The grids are to be designed by taking account of beamlet-beamlet interaction in three-dimensional simulation. Third is to maintain the D- production for 100 s. A simple cooling structure is proposed for the active cooled plasma grid, where a key is the temperature gradient on the plasma grid for uniform D- production. The modified N-NBI ion source will start on JT-60SA in 2015.

Journal Articles

Long pulse production of high current D$$^{-}$$ ion beams in the JT-60 negative ion source

Hanada, Masaya; Kamada, Masaki; Akino, Noboru; Ebisawa, Noboru; Honda, Atsushi; Kawai, Mikito; Kazawa, Minoru; Kikuchi, Katsumi; Komata, Masao; Mogaki, Kazuhiko; et al.

Review of Scientific Instruments, 79(2), p.02A519_1 - 02A519_4, 2008/02

 Times Cited Count:6 Percentile:32.32(Instruments & Instrumentation)

A long pulse production of high-current, high-energy D$$^{-}$$ ion beams was studied in the JT-60U negative ion source that was designed to produce 22 A, 500 keV D$$^{-}$$ ion beams. Prior to the long pulse production, the short pulse beams were produced to examine operational ranges for a stable voltage holding capability and an allowable grid power loading. From a correlation between the voltage holding capability and a light intensity of cathodoluminescence from the insulator made of Fiber Reinforced Plastic insulator, the voltage holding was found to be stable at $$<$$ 340 kV where the light was sufficiently suppressed. The grid power loading for the long pulse operation was also decreased to the allowable level of $$<$$ 1 MW without a significant reduction of the beam power by tuning the extraction voltage (Vext) and the arc power (Parc). These allow the production of 30 A D$$^{-}$$ ion beams at 340 keV from two ion sources at Vacc = 340 kV. The pulse length was extended step by step, and finally reached up to 21 s, where the beam pulse length was limited by the surface temperature of the beam scraper without water cooling. The D$$^{-}$$ ion beams were neutralized to via a gas cell, resulting in a long pulse injection of 3.2 MW D$$^{0}$$ beams for 21 s. This is the first long injection of $$>$$ 20 s in a power range of $$>$$ 3 MW.

Journal Articles

Correlation between voltage holding capability and light emission in a 500 keV electrostatic accelerator utilized for fusion application

Hanada, Masaya; Ikeda, Yoshitaka; Kamada, Masaki; Kikuchi, Katsumi; Komata, Masao; Mogaki, Kazuhiko; Umeda, Naotaka; Usui, Katsutomi; Grisham, L. R.*; Kobayashi, Shinichi*

IEEE Transactions on Dielectrics and Electrical Insulation, 14(3), p.572 - 576, 2007/06

 Times Cited Count:5 Percentile:33.65(Engineering, Electrical & Electronic)

Voltage holding capability of a 500 keV 22 A negative ion accelerator for JT-60U was experimentally examined. Voltage holding capability was strongly correlated with intensity of the light emitted inside the accelerator by applying the acceleration voltage. Namely, stable voltage holding was realized when the light emission was well suppressed. To examine the origin of the light emission, the correlation between the light intensity and the dark current was measured. The light intensity was linearly varied with the dark current. Further, it was indicated from the direction of the dark current that electrons were emitted from cathode grids by applying the acceleration voltage. In addition, the spectroscopy measurement of the light showed that the light had a broad peak at 420 nm. No particular spectra of hydrogen, oxygen and carbon have been observed. Therefore, the light emission seemed to be originated by electron excitation of FRP itself. From these results, it was thought that the voltage holding capability of the JT-60U negative ion accelerator could be improved by suppressing the electron emission from the cathode grids.

Journal Articles

Present status of the negative ion based NBI system for long pulse operation on JT-60U

Ikeda, Yoshitaka; Umeda, Naotaka; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Hanada, Masaya; Honda, Atsushi; Inoue, Takashi; Kawai, Mikito; Kazawa, Minoru; et al.

Nuclear Fusion, 46(6), p.S211 - S219, 2006/06

 Times Cited Count:59 Percentile:87.2(Physics, Fluids & Plasmas)

Recently, the extension of the pulse duration up to 30 sec has been intended to study quasi-steady state plasma on JT-60U N-NBI system. The most serious issue is to reduce the heat load on the grids for long pulse operation. Two modifications have been proposed to reduce the heat load. One is to suppress the beam spread which may be caused by beamlet-beamlet interaction in the multi-aperture grid due to the space charge force. Thin plates were attached on the extraction grid to modify the local electric field. The plate thickness was optimized to steer the beamlet deflection. The other is to reduce the stripping loss, where the electron of the negative ion beam is stripped and accelerated in the ion source and then collides with the grids. The ion source was modified to reduce the pressure in the accelerator column to suppress the beam-ion stripping loss. Up to now, long pulse injection of 17 sec for 1.6 MW and 25 sec for $$sim$$1 MW has been obtained by one ion source with these modifications.

Journal Articles

Development of a traveling wave resonant ring of the JNC high-power, high-duty electron linac

Nomura, Masahiro; Wang, Y. L.; Yamazaki, Yoshio; Hirano, Koichiro; Kato, Yuko*; Ishikawa, Takehiro*; Komata, Tomoki*; Hiyama, Toru*

Nuclear Instruments and Methods in Physics Research A, 463(1-2), p.42 - 49, 2001/05

 Times Cited Count:0 Percentile:0.01(Instruments & Instrumentation)

None

Journal Articles

Long-lived radionuclide transport; An In-situ field column study

D.R.Champ*; J.O.Jirovec*; J.L.Young*; Kumata, Masahiro

Transport and Mass Exchange Processes in Sand and Gravel Aquifers; Field and Modelling Studies,Vol. 2, p.725 - 736, 1991/00

no abstracts in English

Oral presentation

Characterization of NV centers created by ion implantation with the energy ranging from keV to Sub GeV

Onoda, Shinobu; Haruyama, Moriyoshi; Teraji, Tokuyuki*; Isoya, Junichi*; Christoph, M.*; McGuinness, L.*; Balasubramanian, P.*; Naydenov, B.*; Jelezko, F.*; Koike, Godai*; et al.

no journal, , 

no abstracts in English

Oral presentation

Current status of creation technique of color centers in diamonds by quantum beams

Onoda, Shinobu; Haruyama, Moriyoshi; Teraji, Tokuyuki*; Isoya, Junichi*; Koike, Godai*; Higashimata, Itaru*; Inaba, Masafumi*; Yamano, Hayate*; Kato, Kanami*; Christoph, M.*; et al.

no journal, , 

no abstracts in English

Oral presentation

Radon measurements in a small chamber using compact organic scintillator-based alpha/beta spectrometer

Morishita, Yuki; Ye, Y.*; Mata, L.*; Pozzi, S.*; Kearfott, K.*

no journal, , 

A compact organic scintillator-based $$alpha beta$$ spectrometer was developed and tested for radon measurements. The spectrometer was composed of a Through Silicon Via (TSV) silicon photomultiplier or SiPM and a 6 mm $$times$$ 6 mm $$times$$ 6 mm stilbene cube crystal. Analog signals from the SiPM were sent to a digitizer. The detector was placed in a light-tight box and a stacked air filter was embedded on the side surface of the light-tight box. A continuous radon monitor, the AlphaGUARD, and $$^{226}$$Ra sources were placed in a small radon chamber constructed using a cylindrical 0.57 m diameter, 0.88 m tall steel drum. By applying a pulse shape discrimination technique, alpha and beta spectra were simultaneously clearly separated and quantitatively measured. Two peaks were registered in the measured alpha spectrum: $$^{218}$$Po was registered in the lower peak and $$^{214}$$Po was registered in the higher peak. A linear relationship was observed between radon counts from the AlphaGUARD and count-rates from the stilbene-SiPM detector. The thickness of the stilbene-SiPM detector was less than 10 mm, thus easy increases insensitivity should be possible with future construction. Thus, the compact organic scintillator-based alpha/beta spectrometer shows promise for use in novel radon detection systems.

20 (Records 1-20 displayed on this page)
  • 1