Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Saito, Hiroyuki; Machida, Akihiko; Matsuoka, Takehiro*; Aoki, Katsutoshi*
Solid State Communications, 205, p.24 - 27, 2015/03
Times Cited Count:9 Percentile:37.08(Physics, Condensed Matter)Kiriyama, Hiromitsu; Mori, Michiaki; Suzuki, Masayuki*; Daito, Izuru*; Okada, Hajime; Ochi, Yoshihiro; Tanaka, Momoko; Sato, Masatoshi*; Tamaoki, Yoshinori*; Yoshii, Takehiro*; et al.
Reza Kenkyu, 42(6), p.441 - 447, 2014/06
We describe three specific high power laser systems that are being developed in our laboratory for many applications in high field science, nonlinear optics and material processing. We report on a femtosecond petawatt-class Ti:sapphire chirped-pulse amplification laser system that can produce a pulse energy of 20 J of 40 fs pulse duration, a picosecond high intensity Yb:YAG chirped-pulse amplification laser system that can generate a pulse energy of 100 mJ of 0.5 ps pulse duration, and a nanosecond high repetition rate Nd:YAG laser system that can provide an average power of 360 W with a pulse duration of 30 ns delivered at a 1 kHz repetition rate. We discuss the basic design aspects and present the results from our experimental investigations of these laser systems.
Mitsui, Takaya; Masuda, Ryo*; Seto, Makoto; Hirao, Naohisa*; Matsuoka, Takehiro*; Nakamura, Yumiko*; Sakaki, Koji*; Enoki, Hirotoshi*
Journal of Alloys and Compounds, 580(Suppl.1), p.S264 - S267, 2013/12
Times Cited Count:8 Percentile:41.04(Chemistry, Physical)Suzuki, Masayuki; Kiriyama, Hiromitsu; Daito, Izuru; Okada, Hajime; Ochi, Yoshihiro; Sato, Masatoshi*; Yoshii, Takehiro*; Tamaoki, Yoshinori*; Maeda, Junya*; Matsuoka, Shinichi*; et al.
AIP Conference Proceedings 1465, p.53 - 57, 2012/07
Times Cited Count:0 Percentile:0.00(Physics, Applied)We have reported hundred mJ level, femtosecond pulse duration with the high temporal contrast in an OPCPA/Yb:YAG ceramic thin disk laser system at 10 Hz repetition rate. At an input laser pulse energy of 3.8 mJ from the OPCPA preamplifer the output energy of 130 mJ with spectral bandwidth of 2.5 nm has been obtained from multipass Yb:YAG ceramic thin disk amplifier, and the optical efficiency from LD energy to amplified laser pulse is 9.6%. The recompressed laser pulse duration was measured to be 450 fs. Because the compressor efficiency exceeds 73% the compressed pulse energy can potentially be as high as 95 mJ. The contrast level of this laser pulse was measured to be less than 7.210
at -150 ps. This novel laser system after further amplification using additional amplifiers can be useful for the laser-driven proton acceleration in future.
Kiriyama, Hiromitsu; Suzuki, Masayuki*; Daito, Izuru; Okada, Hajime; Ochi, Yoshihiro; Sato, Masatoshi*; Tamaoki, Yoshinori*; Yoshii, Takehiro*; Maeda, Junya*; Matsuoka, Shinichi*; et al.
Reza Kenkyu, 40(2), p.143 - 145, 2012/02
We demonstrate a compact, high-spatiotemporal-quality, high-intensity diode-pumped Yb:YAG thin-disk chirped-pulse amplification (CPA) laser system that incorporates a nonlinear preamplifier based on optical parametric chirped-pulse amplification (OPCPA). The stretched pulses are amplified in the OPCPA preamplifier and the following Yb:YAG main amplifier to 100 mJ at 10 Hz. The broadband amplified beam quality of 1.1 (horizontal direction) and 1.4 (vertical direction) times diffraction limited and pulse compression down to 470 fs with contrast of better than 10
have been achieved successfully.
Suzuki, Masayuki*; Kiriyama, Hiromitsu; Daito, Izuru; Ochi, Yoshihiro; Okada, Hajime; Sato, Masatoshi*; Tamaoki, Yoshinori*; Yoshii, Takehiro*; Maeda, Junya*; Matsuoka, Shinichi*; et al.
Applied Physics B, 105(2), p.181 - 184, 2011/11
Times Cited Count:5 Percentile:28.00(Optics)We have demonstrated an OPCPA/Yb:YAG ceramic thin disk hybrid laser system having hundred mJ level pulse energy sub-picosecond pulse duration with high temporal contrast. At an input energy of 3.8 mJ from an OPCPA preamplifier an output energy of 130 mJ was obtained from Yb:YAG ceramic thin disk amplifier. A recompressed pulse duration of 450 fs with a contrast level of less than 7.210
was obtained. The contrast level is the highest value achieved in Yb:YAG chirped pulse amplification (CPA) laser system with hundred mJ level.
Matsuoka, Takehiro*; Hirao, Naohisa*; Oishi, Yasuo*; Shimizu, Katsuya*; Machida, Akihiko; Aoki, Katsutoshi
Koatsuryoku No Kagaku To Gijutsu, 21(3), p.190 - 196, 2011/09
We present the newly developed electrical resistance measurement technique for metal hydrides compressed in high-pressure H and the first successful
simultaneous measurements of electrical resistance and X-ray diffraction of FeH at high pressures and low temperatures. The electrical resistivity
showed a sharp increase with the formation of iron-hydride FeH
(
) at 3.5 GPa. The
'-phase of FeH was found to be metallic up to 25.5 GPa. The
vs.
curves up to 16.5 GPa approximately follow Fermi-liquid law below 25 K. However,
was found to be better fitting at 25.5 GPa. This change can be related to the previously reported ferromagnetism collapse at corresponding pressures.
Suzuki, Masayuki; Kiriyama, Hiromitsu; Daito, Izuru; Okada, Hajime; Nakai, Yoshiki; Orimo, Satoshi; Sato, Masatoshi*; Tamaoki, Yoshinori*; Yoshii, Takehiro*; Maeda, Junya*; et al.
Applied Physics B, 97(2), p.379 - 382, 2009/10
Times Cited Count:7 Percentile:36.93(Optics)We report the highest energy broadband laser pulses at a center wavelength of 1030 nm based on optical parametric chirped-pulse amplification (OPCPA). We have demonstrated amplification of 1030 nm femtosecond laser pulses from a broadband Yb oscillator to over 6.5 mJ with a total gain of greater than 10 achieved in a single pass through only 56 mm of gain material at a 10 Hz repetition rate. The amplified spectral bandwidth of 10.8 nm affords recompression to a 230 fs pulse duration following amplification. As an alternative to the regenerative amplifier (RA) this system is one of the more promising candidates for realizing compact, high intensity, direct diode pumped, high repetition rate femtosecond Yb:YAG chirped-pulse amplification (CPA) in laser systems.
Matsuoka, Takehiro*; Kitayama, Takayasu*; Shimizu, Katsuya*; Nakamoto, Yuki*; Kagayama, Tomoko*; Aoki, Katsutoshi; Oishi, Yasuo*; Takemura, Kenichi*
High Pressure Research, 26(4), p.391 - 394, 2006/12
Times Cited Count:3 Percentile:26.27(Physics, Multidisciplinary)The electrical and structural properties of yttrium hydride YHx was studied by the in-situ measurements of the electrical resistance and X-ray diffraction up to 86 GPa. The electrical resistivity increased with applying pressure up to 10 GPa and showed a maximum which accompanied with the structural transition of metal lattice from hcp to fcc structure. In fcc phase the resistivity decreased significantly, however the value still remained larger by 4 orders of magnitude that that of pure yttrium metal. We could not confirm the insulator to metal transition up to 23 GPa. The resistivity showed another maximum in the large pressure region 40 60 GPa without the structural phase transition of metal lattice.
Suzuki, Masayuki*; Kiriyama, Hiromitsu; Daito, Izuru; Okada, Hajime; Ochi, Yoshihiro; Sato, Masatoshi*; Yoshii, Takehiro*; Tamaoki, Yoshinori*; Maeda, Junya*; Matsuoka, Shinichi*; et al.
no journal, ,
no abstracts in English
Kiriyama, Hiromitsu; Mori, Michiaki; Shimomura, Takuya; Nakai, Yoshiki*; Tanoue, Manabu*; Sasao, Hajime*; Kondo, Shuji; Kanazawa, Shuhei; Ochi, Yoshihiro; Tanaka, Momoko; et al.
no journal, ,
We report on a femtosecond high-intensity OPCPA/Ti:sapphire hybrid laser system that produces more than 30 J broadband output energy, indicating the potential for achieving petawatt-class peak powers. High temporal-contrast of 10 to 10
has been obtained with a near-perfect flat-topped spatial-profile of filling factor
80%. We also present a compact, high-intensity OPCPA/Yb:YAG hybrid laser system that generates
100 mJ output energy with a temporal contrast of better than 10
and good spatial beam quality.
Watanuki, Tetsu; Matsuoka, Takehiro*
no journal, ,
no abstracts in English
Mitsui, Takaya; Masuda, Ryo; Hirao, Naohisa*; Matsuoka, Takehiro*
no journal, ,
no abstracts in English
Watanuki, Tetsu; Matsuoka, Takehiro*
no journal, ,
no abstracts in English
Suzuki, Masayuki; Kiriyama, Hiromitsu; Daito, Izuru; Okada, Hajime; Bolton, P.; Sugiyama, Akira; Kondo, Kiminori; Kawanishi, Shunichi*; Sato, Masatoshi*; Tamaoki, Yoshinori*; et al.
no journal, ,
At our Institute we are developing a compact ion accelerator for cancer therapy using a laser-driven plasma point source of ions. The laser system was consisted of an oscillator, Offner stretcher, optical parametric amplifier (OPCPA), LD pumped Yb:YAG amplifier, and compressor. In OPCPA the stretched laser pulse after the pulse stretcher was amplified to 3.8 mJ with only a 12.8 nJ input. After amplification in the OPCPA laser pulse was further amplified by an Yb:YAG thin disk module which was pumped by the Q-CW LD. The maximum output energy was about 80 mJ in a multi-pass scheme (20 pass) at 10 Hz. The compressed pulse duration is about 520 fs, and the contrast level before the main pulse is measured as 10 at -150 ps. We have developed that new high intensity, high contrast femtosecond OPCPA/LD-pumped Yb:YAG hybrid laser system. This novel system might represent the driver in integrated, laser-driven ion accelerator systems.
Suzuki, Masayuki; Kiriyama, Hiromitsu; Daito, Izuru; Okada, Hajime; Sato, Masatoshi*; Yoshii, Takehiro*; Tamaoki, Yoshinori*; Matsuoka, Shinichi*; Kan, Hirofumi*; Bolton, P.; et al.
no journal, ,
no abstracts in English
Suzuki, Masayuki; Kiriyama, Hiromitsu; Daito, Izuru; Okada, Hajime; Nakai, Yoshiki; Orimo, Satoshi; Sato, Masatoshi*; Tamaoki, Yoshinori*; Yoshii, Takehiro*; Maeda, Junya*; et al.
no journal, ,
We have reported the demonstration of an optical parametric chirped-pulse amplification (OPCPA) operating at 1030 nm. A total OPCPA output energy of 6.5 mJ (uncompressed) with gain exceeding of 10 has been achieved with a spectral bandwidth of 10.8 nm and a recompressed pulse duration of 230 fs. This novel system is a promising alternative to the RA as a nonlinear preamplifier for compact, high intensity, Yb:YAG CPA laser using DPPSL systems.
Kiriyama, Hiromitsu; Mori, Michiaki; Shimomura, Takuya; Tanoue, Manabu; Kondo, Shuji; Kanazawa, Shuhei; Daito, Izuru; Suzuki, Masayuki*; Okada, Hajime; Ochi, Yoshihiro; et al.
no journal, ,
We describe two specific high intensity laser systems that are being developed in our laboratory for many applications such as high field science, nonlinear optics. We report on an ultra-high intensity petawatt-class Ti:sapphire chirped-pulse amplification laser system that can produce a pulse energy of 18 J with
30 fs pulse duration for studying extremely high intensity laser matter interaction process and a small-scaled Yb:YAG chirped-pulse amplification laser system that can generate a pulse energy of
100 m J of
500 fs pulse duration for compact, high efficiency, high repetition system. We discuss the basic design aspects and present the results from our experimental investigations of these laser systems.
Suzuki, Masayuki; Kiriyama, Hiromitsu; Daito, Izuru; Okada, Hajime; Sato, Masatoshi*; Matsuoka, Shinichi*; Yoshii, Takehiro*; Kan, Hirofumi*; Bolton, P.; Daido, Hiroyuki; et al.
no journal, ,
Suzuki, Masayuki; Kiriyama, Hiromitsu; Daito, Izuru; Okada, Hajime; Nakai, Yoshiki*; Daido, Hiroyuki; Bolton, P.; Sugiyama, Akira; Kondo, Kiminori; Kawanishi, Shunichi; et al.
no journal, ,
At our Institute we are developing a compact ion accelerator for cancer therapy using a laser-driven plasma point source of ions. The laser system was consisted of an oscillator, offner stretcher, optical parametric amplifier (OPCPA), LD pumped Yb:YAG amplifier, and compressor. In OPCPA the stretched laser pulse after the pulse stretcher was amplified to 5 mJ with only a 0.2 mJ input. After amplification in the OPCPA laser pulse was further amplified by an Yb:YAG (5 at%) thin disk module which was pumped by the Q-CW LD. The maximum output energy was about 120 mJ in a multi-pass scheme (20 pass) at 10 Hz. The compressed pulse duration is about 300 fs, and the contrast level before the main pulse is measured as 10 at -150 ps. We have developed that new high intensity, high contrast femtosecond OPCPA/LD-pumped Yb:YAG hybrid laser system. This novel system might represent the driver in integrated, laser-driven ion accelerator systems.