Refine your search:     
Report No.
 - 
Search Results: Records 1-12 displayed on this page of 12
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Morphological reproductive characteristics of testes and fertilization capacity of cryopreserved sperm after the Fukushima accident in raccoon (${it Procyon lotor}$)

Komatsu, Kazuki*; Iwasaki, Tsugumi*; Murata, Kosuke*; Yamashiro, Hideaki*; Goh, V. S. T.*; Nakayama, Ryo*; Fujishima, Yohei*; Ono, Takumi*; Kino, Yasushi*; Shimizu, Yoshinaka*; et al.

Reproduction in Domestic Animals, 56(3), p.484 - 497, 2021/03

 Times Cited Count:9 Percentile:88.06(Agriculture, Dairy & Animal Science)

We have established an archive system of livestock and wild animals from the surrounding ex-evacuation zone. Wildlife within the alert zone have been exposed to low-dose-rate (LDR) radiation for a long and continuous time. In this study, we analysed the morphological characteristics of the testes and in vitro fertilization (IVF) capacity of cryopreserved sperm of raccoons from the ex-evacuation zone of the FDNPP accident. This study revealed that the chronic and LDR radiation exposure associated with the FDNPP accident had no adverse effect on the reproductive characteristics and functions of male raccoons.

Journal Articles

Progress report of Japanese simulation research projects using the high-performance computer system Helios in the International Fusion Energy Research Centre

Ishizawa, Akihiro*; Idomura, Yasuhiro; Imadera, Kenji*; Kasuya, Naohiro*; Kanno, Ryutaro*; Satake, Shinsuke*; Tatsuno, Tomoya*; Nakata, Motoki*; Nunami, Masanori*; Maeyama, Shinya*; et al.

Purazuma, Kaku Yugo Gakkai-Shi, 92(3), p.157 - 210, 2016/03

The high-performance computer system Helios which is located at The Computational Simulation Centre (CSC) in The International Fusion Energy Research Centre (IFERC) started its operation in January 2012 under the Broader Approach (BA) agreement between Japan and the EU. The Helios system has been used for magnetised fusion related simulation studies in the EU and Japan and has kept high average usage rate. As a result, the Helios system has contributed to many research products in a wide range of research areas from core plasma physics to reactor material and reactor engineering. This project review gives a short catalogue of domestic simulation research projects. First, we outline the IFERC-CSC project. After that, shown are objectives of the research projects, numerical schemes used in simulation codes, obtained results and necessary computations in future.

Journal Articles

Twiss parameter matching of the injection beam for the J-PARC RCS

Okabe, Kota; Maruta, Tomofumi*; Hotchi, Hideaki; Saha, P. K.; Yoshimoto, Masahiro; Miura, Akihiko; Liu, Y.*; Kinsho, Michikazu

Proceedings of 12th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.933 - 937, 2015/09

In a high power proton accelerator such as the 3-GeV rapid cycle synchrotron (RCS), small ratio of the beam loss such as beam halo can cause serious radiation dose. The suppression of the transverse beam halo is a key issue to provide high intensity beam for routine user operation at the RCS. If the transverse twiss parameter of the injection beam is not matched to the RCS optics, it will generates beam halo during the multi-turn injection. In order to suppress such beam halo, twiss parameters and dispersion matching are performed at the RCS injection point. In the beam matching process, we use the rms envelope equation solver with space charge effect to predict high intensity beam behavior. The beam profile measurement is done with wire scanner monitors at the downstream of the L3BT as well as multi-wire profile monitors at the RCS injection section. In this presentation, we introduce the transverse twiss parameter matching scheme at the RCS injection points.

Journal Articles

Experimental evidence of nonthermal acceleration of relativistic electrons by an intensive laser pulse

Kuramitsu, Yasuhiro*; Nakanii, Nobuhiko*; Kondo, Kiminori; Sakawa, Yoichi*; Mori, Yoshitaka*; Miura, Eisuke*; Tsuji, Kazuki*; Kimura, Kazuya*; Fukumochi, Shuji*; Kashihara, Mamoru*; et al.

Physical Review E, 83(2), p.026401_1 - 026401_6, 2011/02

 Times Cited Count:16 Percentile:65.84(Physics, Fluids & Plasmas)

An energy distribution function of energetic particles in the universe or cosmic rays is well represented by a power-law spectrum, therefore, nonthermal acceleration is essential to understand the origin of cosmic rays. A possible candidate for the origin of cosmic rays is wakefield acceleration at relativistic astrophysical perpendicular shocks. Substituting an intensive laser pulse for the large amplitude light waves, we performed a model experiment of the shock environments in a laboratory plasma.

Journal Articles

Model experiment of cosmic ray acceleration due to an incoherent wakefield induced by an intense laser pulse

Kuramitsu, Yasuhiro*; Nakanii, Nobuhiko*; Kondo, Kiminori; Sakawa, Yoichi*; Mori, Yoshitaka*; Miura, Eisuke*; Tsuji, Kazuki*; Kimura, Kazuya*; Fukumochi, Shuji*; Kashihara, Mamoru*; et al.

Physics of Plasmas, 18(1), p.010701_1 - 010701_4, 2011/01

 Times Cited Count:19 Percentile:62.63(Physics, Fluids & Plasmas)

Substituting an intensive laser pulse for the large amplitude light waves, we performed a model experiment of the shock environments in a laboratory plasma. An intensive laser pulse was propagated in a plasma tube created by imploding a hollow polystyrene cylinder, as the large amplitude light waves propagated in the upstream plasma at an astrophysical shock. Nonthermal electrons were generated, and the energy distribution functions of the electrons have a power-law component with an index of 2.

Journal Articles

Spectrum modulation of relativistic electrons by laser wakefield

Nakanii, Nobuhiko*; Kondo, Kiminori; Kuramitsu, Yasuhiro*; Mori, Yoshitaka*; Miura, Eisuke*; Tsuji, Kazuki*; Kimura, Kazuya*; Fukumochi, Shuji*; Kashihara, Mamoru*; Tanimoto, Tsuyoshi*; et al.

Applied Physics Letters, 93(8), p.081501_1 - 081501_3, 2008/08

 Times Cited Count:4 Percentile:18.82(Physics, Applied)

Energetic electrons were generated by the interaction of a high-intensity laser pulse with a plasma preformed from a hollow plastic cylinder via laser-driven implosion. The spectra of a comparatively high-density plasma had a bump around 10 MeV. Simple numerical calculations explained the spectra obtained in this experiment. This indicates that the plasma tube has sufficient potential to convert a Maxwellian spectrum to a comparatively narrow spectrum.

Oral presentation

Applicability evaluation of k$$_{0}$$-neutron activation analysis for biological reference material

Matsue, Hideaki; Kuroiwa, Takayoshi*; Miura, Tsutomu*

no journal, , 

no abstracts in English

Oral presentation

Maintenance management of fuel handling and storage system in the experimental fast reactor "JOYO"

Kawakami, Shodai; Suzuki, Toshiaki; Takahashi, Tsuyoshi*; Fujinaka, Hideaki; Miura, Yoshiyuki

no journal, , 

no abstracts in English

Oral presentation

External dose estimation of Japanese macaque and Procyon lotor using electron spin resonance spectroscopy

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Ono, Takumi*; Tamaki, Hiroaki*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.

no journal, , 

Releases of the radioactive materials from the Fukushima Daiichi Nuclear Power Plant accident result in an ionization exposure to people and animals, the precise dosimetry is required. To estimate the external dose due to the accident, we utilize electron spin resonance (ESR) spectroscopy which is a powerful tool for the dosimetry of external dose. The detection limit of this technique was 146 mGy, so that we have to improve the detection limit for the precise dosimetry. In this work, we developed a novel enamel-dentine separation technique and improved the detection limit down to 43 mGy, and estimated the external dose for Japanese macaque and Procyon lotor collected in Fukushima prefecture.

Oral presentation

Sample preparation procedure for the estimation of external exposure dose of wild animals using elecron spin resonance spectroscopy

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Ono, Takumi*; Tamaki, Hiroaki*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

no journal, , 

Release of the radioactive materials from Fukushima Daiichi Nuclear Power Plant accident results in a long-term low dose rate ionization exposure to wild animals. The biological effects of the wild animal do not show a clear correlation with the external dose, which is estimated from the external dose rate of the captured point of the animal, a precise external dose estimation using ESR and tooth enamel is required instead of using the external dose rate. In this work, we attempted to estimate the external dose of wild Japanese macaque and Procyon lotor captured in the high dose rate area.

Oral presentation

Sample preparation procedure for ESR dosimetry using teeth of wild animal

Oka, Toshitaka; Mitsuyasu, Yusuke*; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Sekine, Tsutomu*; Okutsu, Kenichi*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

no journal, , 

Releases of the radioactive materials from the Fukushima Daiichi Nuclear Power Plant accident result in a low dose exposure to wild animals. The external dose of wild animals is commonly estimated by the external dose rate of the captured point, but the estimated exposure dose has huge uncertainties because the size of the habitat and/or the movement of the wild animals are not included in the estimation. To estimate the external dose precisely, we utilize electron spin resonance (ESR) dosimetry. In this work, we investigated the sample preparation procedure of wild animals. The ESR spectrum of enamel of racoon captured in Namie-town, Fukushima has a broad ESR signal due to metal components. The linear relationship between the Co$$_{2}$$ intensity and the absorbed dose that we can apply ESR dosimetry for racoon teeth. Using this relationship, the external exposure dose was estimated.

Oral presentation

External exposure dose estimation using ESR dosimetry technique

Oka, Toshitaka; Takahashi, Atsushi*; Mitsuyasu, Yusuke*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Yamashita, Takuma*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

no journal, , 

Electron spin resonance (ESR) dosimetry technique is a powerful tool that has been used in the study of external exposure dose assessment of human by measuring CO$$_{2}$$ radicals of teeth. In this work, we applied this technique for wild monkey and wild racoon captured in Fukushima prefecture, and estimated the external exposure dose.

12 (Records 1-12 displayed on this page)
  • 1