Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Kitazato, Kohei*; Milliken, R. E.*; Iwata, Takahiro*; Abe, Masanao*; Otake, Makiko*; Matsuura, Shuji*; Takagi, Yasuhiko*; Nakamura, Tomoki*; Hiroi, Takahiro*; Matsuoka, Moe*; et al.
Nature Astronomy (Internet), 5(3), p.246 - 250, 2021/03
Times Cited Count:44 Percentile:96.99(Astronomy & Astrophysics)Here we report observations of Ryugu's subsurface material by the Near-Infrared Spectrometer (NIRS3) on the Hayabusa2 spacecraft. Reflectance spectra of excavated material exhibit a hydroxyl (OH) absorption feature that is slightly stronger and peak-shifted compared with that observed for the surface, indicating that space weathering and/or radiative heating have caused subtle spectral changes in the uppermost surface. However, the strength and shape of the OH feature still suggests that the subsurface material experienced heating above 300 C, similar to the surface. In contrast, thermophysical modeling indicates that radiative heating does not increase the temperature above 200 C at the estimated excavation depth of 1 m, even if the semimajor axis is reduced to 0.344 au. This supports the hypothesis that primary thermal alteration occurred due to radiogenic and/or impact heating on Ryugu's parent body.
Tamakuma, Yuki*; Yamada, Ryohei; Suzuki, Takahito*; Kuroki, Tomohiro*; Saga, Rikiya*; Mizuno, Hiroyuki*; Sasaki, Hiroyuki*; Iwaoka, Kazuki*; Hosoda, Masahiro*; Tokonami, Shinji*
Radiation Protection Dosimetry, 184(3-4), p.307 - 310, 2019/10
Times Cited Count:1 Percentile:10.65(Environmental Sciences)After the Fukushima Daiichi Nuclear Power Plant accident, the radiation dose for first responders was not evaluated accurately due to lack of the monitoring data. It has been important to evaluate a radiation dose for workers in emergency response at a nuclear accident. In this study, a new device which can evaluate both of external and internal exposure doses was developed and the performance of various environmental radiation monitors including commercially available monitors were tested and compared from the viewpoint of an environmental monitoring at emergency situation. Background counts of the monitors and the ambient dose equivalent rate were measured in Fukushima Prefecture. The detection limit for beta particles was evaluated by the method of ISO11929. The sensitivity for gamma-rays of the dust monitor using a ZnS(Ag) and a plastic scintillator was high, but that of the external exposure monitor using a silicon photodiode with CsI(Tl) crystal was relatively low. The detection limit ranged 190-280 Bq m at 100 Sv h, exceeding the detection limit of 100 Bq m in the minimum requirement by the National Regulation Authority in Japan. Use of the shielding with lead is necessary to achieve the minimum requirement. These results indicate that the dust monitor using a ZnS(Ag) scintillator and a plastic scintillator is suitable for the external exposure monitor and the developed internal exposure monitor is for the internal exposure monitor at emergency situation among the evaluated monitors. In the future study, the counting efficiency, the relative uncertainty and the performance of the detection for alpha particles will be evaluated, and it will be considered which type of a monitor is suitable after taking the portability into account.
Tamakuma, Yuki*; Yamada, Ryohei; Iwaoka, Kazuki*; Hosoda, Masahiro*; Kuroki, Tomohiro*; Mizuno, Hiroyuki*; Yamada, Koji*; Furukawa, Masahide*; Tokonami, Shinji*
Perspectives in Science (Internet), 12, p.100414_1 - 100414_4, 2019/09
In this study, a portable radioactive plume monitor using a silicon photodiode was developed for the detection of a radioactive plume (e.g. I, Cs and Cs) in an emergency situation. It was found that the background count rate was proportional to ambient dose equivalent rate and the detection limit for the monitor at 20 Sv h as an ambient dose equivalent rate was evaluated to be 187 Bq m using the ISO11929 method. These results suggest that the detection limit for the system can be decreased effectively by lead shielding with optimized thickness.
Konomura, Mamoru; Ogawa, Takashi; Okano, Yasushi; Yamaguchi, Hiroyuki; Murakami, Tsutomu; Takaki, Naoyuki; Nishiguchi, Youhei; Sugino, Kazuteru; Naganuma, Masayuki; Hishida, Masahiko; et al.
JNC TN9400 2004-035, 2071 Pages, 2004/06
The attractive concepts for Sodium-, lead-bismuth-, helium- and water-cooled FBRs have been created through using typical plant features and employing advanced technologies. Efforts on evaluating technological prospects of feasibility have been paid for these concepts. Also, it was comfirmed if these concepts satisfy design requierments of capability and performance presumed in the feasibilty study on commertialization of Fast Breeder Reactor Systems. As results, it was concluded that the selection of sodium-cooled reactor was most rational for practical use of FBR technologies in 2015.
Mizuno, Tomohiro*; Odaira, Naoya*; Ito, Daisuke*; Ito, Kei*; Saito, Yasushi*; Imaizumi, Yuya; Matsuba, Kenichi; Kamiyama, Kenji
no journal, ,
no abstracts in English
Mizuno, Tomohiro*; Odaira, Naoya*; Ito, Daisuke*; Ito, Kei*; Saito, Yasushi*; Imaizumi, Yuya; Matsuba, Kenichi; Kamiyama, Kenji
no journal, ,
no abstracts in English