Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Komatsu, Kazuki*; Iwasaki, Tsugumi*; Murata, Kosuke*; Yamashiro, Hideaki*; Goh, V. S. T.*; Nakayama, Ryo*; Fujishima, Yohei*; Ono, Takumi*; Kino, Yasushi*; Shimizu, Yoshinaka*; et al.
Reproduction in Domestic Animals, 56(3), p.484 - 497, 2021/03
Times Cited Count:10 Percentile:83.43(Agriculture, Dairy & Animal Science)We have established an archive system of livestock and wild animals from the surrounding ex-evacuation zone. Wildlife within the alert zone have been exposed to low-dose-rate (LDR) radiation for a long and continuous time. In this study, we analysed the morphological characteristics of the testes and in vitro fertilization (IVF) capacity of cryopreserved sperm of raccoons from the ex-evacuation zone of the FDNPP accident. This study revealed that the chronic and LDR radiation exposure associated with the FDNPP accident had no adverse effect on the reproductive characteristics and functions of male raccoons.
Suzuki, Akifumi; Suzuki, Takehiko; Takahashi, Masa; Nakata, Toru; Murayama, Takashi; Tsunoda, Masahiko
JAEA-Technology 2014-049, 19 Pages, 2015/03
Optically Stimulated Luminescence, OSL, dosimeters have been used as individual dosimeters for external radiation in Nuclear Science Research Institute and so on since October, 2014 as successor of the RPL glass dosimeters. Characteristics of the OSL dosimeters such as dose linearity, energy response, angular dependence, fading characteristics and responses at mixed irradiation fields were examined prior to the start of use. As a result, it was found that the OSL dosimeters met the performances that the national standard (JIS Z 4339) determined. The characteristics of OSL dosimeters were comparable with those of the RPL glass dosimeters. In conclusion, it was confirmed the OSL dosimeters had sufficient performances for the practical use on individual monitoring. This report shows the testing methods and the results for the characteristics of OSL dosimeters.
Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Ono, Takumi*; Tamaki, Hiroaki*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
no journal, ,
Release of the radioactive materials from Fukushima Daiichi Nuclear Power Plant accident results in a long-term low dose rate ionization exposure to wild animals. The biological effects of the wild animal do not show a clear correlation with the external dose, which is estimated from the external dose rate of the captured point of the animal, a precise external dose estimation using ESR and tooth enamel is required instead of using the external dose rate. In this work, we attempted to estimate the external dose of wild Japanese macaque and Procyon lotor captured in the high dose rate area.
Oka, Toshitaka; Mitsuyasu, Yusuke*; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Sekine, Tsutomu*; Okutsu, Kenichi*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
no journal, ,
Releases of the radioactive materials from the Fukushima Daiichi Nuclear Power Plant accident result in a low dose exposure to wild animals. The external dose of wild animals is commonly estimated by the external dose rate of the captured point, but the estimated exposure dose has huge uncertainties because the size of the habitat and/or the movement of the wild animals are not included in the estimation. To estimate the external dose precisely, we utilize electron spin resonance (ESR) dosimetry. In this work, we investigated the sample preparation procedure of wild animals. The ESR spectrum of enamel of racoon captured in Namie-town, Fukushima has a broad ESR signal due to metal components. The linear relationship between the Co intensity and the absorbed dose that we can apply ESR dosimetry for racoon teeth. Using this relationship, the external exposure dose was estimated.
Fujishima, Yohei*; Suzuki, Masatoshi*; Goh, V. S. T.*; Ariyoshi, Kentaro*; Kasai, Kosuke*; Nakata, Akifumi*; Kino, Yasushi*; Oka, Toshitaka; Shinoda, Hisashi*; Shimizu, Yoshinaka*; et al.
no journal, ,
After the Fukushima Daiichi Nuclear Power Plant accident, the surrounding environment was contaminated with radionuclides. Although the ambient dose rates are decreasing, prolonged effects of chronic low-dose exposure on animals are expected to be seen in the coming years. It is necessary to assess the effects of radioactivity on the wild animals in this area to better understand about the risk of low dose radiation. The chromosome translocation frequency of Japanese macaques were significantly higher in Fukushima groups comparing from control groups in Miyagi. Furthermore, chromosome translocation frequencies tended to correlate between external doses or internal dose-rates. However, chromosome translocation frequency was decreasing year by year, which may reflect restoration of environments such as decreasing of ambient dose-rates and decontamination efforts.
Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Ono, Takumi*; Tamaki, Hiroaki*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.
no journal, ,
Releases of the radioactive materials from the Fukushima Daiichi Nuclear Power Plant accident result in an ionization exposure to people and animals, the precise dosimetry is required. To estimate the external dose due to the accident, we utilize electron spin resonance (ESR) spectroscopy which is a powerful tool for the dosimetry of external dose. The detection limit of this technique was 146 mGy, so that we have to improve the detection limit for the precise dosimetry. In this work, we developed a novel enamel-dentine separation technique and improved the detection limit down to 43 mGy, and estimated the external dose for Japanese macaque and Procyon lotor collected in Fukushima prefecture.
Oka, Toshitaka; Takahashi, Atsushi*; Mitsuyasu, Yusuke*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Yamashita, Takuma*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
no journal, ,
Electron spin resonance (ESR) dosimetry technique is a powerful tool that has been used in the study of external exposure dose assessment of human by measuring CO radicals of teeth. In this work, we applied this technique for wild monkey and wild racoon captured in Fukushima prefecture, and estimated the external exposure dose.
Takada, Chie; Nakano, Masanao; Munakata, Masahiro; Yoshida, Tadayoshi; Yokosuka, Yoshiyuki; Yamada, Junya; Maeda, Eita; Watanabe, Yuki; Tomioka, Akifumi; Momose, Takumaro
no journal, ,
no abstracts in English
Takada, Chie; Nakano, Masanao; Munakata, Masahiro; Yoshida, Tadayoshi; Yokosuka, Yoshiyuki; Yamada, Junya; Maeda, Eita; Watanabe, Yuki; Tomioka, Akifumi; Momose, Takumaro
no journal, ,
no abstracts in English
Kurihara, Osamu; Kim, E.*; Yuki, Masanori*; Nakata, Akifumi*; Takashima, Yoshio*; Takada, Misaki*
no journal, ,
We evaluated source efficiency of pig skin samples contaminated with Am-241 nitric aqueous solutions by using alpha-ray spectrometry. We also considered modeling of permeability into the skin tissue based on the measurements.