Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Hong, Z.*; Ahmed, Z.*; Pellegrini, M.*; Yamano, Hidemasa; Erkan, N.*; Sharma, A. K.*; Okamoto, Koji*
Progress in Nuclear Energy, 171, p.105160_1 - 105160_13, 2024/06
In this study, it is found that the eutectic reaction between BC powder and stainless steel (SS) is considerably more rapid than that between the BC pellet and SS. The derived reaction rate constant values for powder and pellet cases are consistently based on the reference values. Also, a composition analysis using SEM/EDS was conducted for the detailed microstructures of the powder and pellet samples. In the powder case, only one thick layer is found as the reaction layer consisting of (Fe, Cr)B precipitate, including BC powder. In the pellet case, two layers are found in the reaction layer.
Baccou, J.*; Glantz, T.*; Ghione, A.*; Sargentini, L.*; Fillion, P.*; Damblin, G.*; Sueur, R.*; Iooss, B.*; Fang, J.*; Liu, J.*; et al.
Nuclear Engineering and Design, 421, p.113035_1 - 113035_16, 2024/05
Ahmed, Z.*; Sharma, A. K.*; Pellegrini, M.*; Yamano, Hidemasa; Okamoto, Koji*
Proceedings of Saudi International Conference On Nuclear Power Engineering (SCOPE2023) (Internet), 8 Pages, 2023/11
In this study, the eutectic behavior and subsequent melt structure of boron migration are observed by a quantitative and high-resolution visualization method using radiative heating. Experiments were conducted using B4C pellet and powder within SS tubes, replicating the actual control rod design in the temperature range of 1150C to 1372C to study long-duration melting and relocation behavior. The visualization technique accurately identified the time of eutectic melting onset and the related temperature, pointing out different values for the pellet and the powder cases.
Tamii, Atsushi*; Pellegri, L.*; Sderstrm, P.-A.*; Allard, D.*; Goriely, S.*; Inakura, Tsunenori*; Khan, E.*; Kido, Eiji*; Kimura, Masaaki*; Litvinova, E.*; et al.
European Physical Journal A, 59(9), p.208_1 - 208_21, 2023/09
Times Cited Count:1 Percentile:0.02(Physics, Nuclear)no abstracts in English
Abeykoon, S.*; Howard, C.*; Dominijanni, S.*; Eberhard, L.*; Kurnosov, A.*; Frost, D. J.*; Boffa Ballaran, T.*; Terasaki, Hidenori*; Sakamaki, Tatsuya*; Suzuki, Akio*; et al.
Journal of Geophysical Research; Solid Earth, 128(9), p.e2023JB026710_1 - e2023JB026710_17, 2023/09
Times Cited Count:0 Percentile:0.01(Geochemistry & Geophysics)Small amounts of iron sulphide minerals are found in most rocks from the Earth's mantle and as inclusions trapped in natural diamonds. Hydrogen may dissolve into iron sulphide minerals under high pressures and temperature, but is most likely lost once pressure and temperature are removed. In this study, we determined deuterium contents in iron sulphide, held under high pressure and temperature conditions, using neutron diffraction measurements with 6-ram multi-anvil press at PLANET, J-PARC. Deuterium contents in iron sulphide were measured at high-P, up to 11.4 GPa and high-T to 1300 K in in situ neutron diffraction experiments. The total deuterium content increases with both P and T. The results are used to estimate hydrogen contents of iron sulphide minerals in the deep continental lithospheric mantle, which are found to be in the range 1700-2700 ppm. This corresponds to approximately 2-3 ppm of hydrogen in the bulk mantle.
Toyoda, Shin*; Inoue, Kazuhiko*; Yamaguchi, Ichiro*; Hoshi, Masaharu*; Hirota, Seiko*; Oka, Toshitaka; Shimazaki, Tatsuya*; Mizuno, Hideyuki*; Tani, Atsushi*; Yasuda, Hiroshi*; et al.
Radiation Protection Dosimetry, 199(14), p.1557 - 1564, 2023/09
Times Cited Count:0 Percentile:0.01(Environmental Sciences)Interlaboratory comparison studies are important for radiation dosimetry in order to demonstrate how the technique is universally available. The set of standard samples are examined in each participating laboratory in the present study. After a set of standard samples together with the samples with unknown doses, which were prepared in the same laboratory as the standard samples, are measured at a participating laboratory, those samples are sent to another participating laboratory for next measurement. There is some small difference observed in the sensitivity (the slope of the dose response line) of the standard samples while the differences in the obtained doses for the samples with unknown doses are rather systematic, implying that the difference is mostly due to the samples but not to measurements.
Yasuda, Satoshi; Dio, W. A.*; Fukutani, Katsuyuki
Vacuum and Surface Science, 66(9), p.514 - 519, 2023/09
Monolayer graphene, representative of atomically thin crystals, has recently shown unexpectedly high proton and deuteron permeability under ambient conditions. It also permeates (filters) hydrogen (deuterium) isotope ion with high selectivity. These results suggest possible ways of developing novel and efficient hydrogen isotope gas enrichment techniques for manufacturing silicon semiconductors, optical fibers, drug development, nuclear fusion, and other related applications. And yet, despite its importance, experimental studies remain scarce and the separation mechanism contentious. Here, we introduce our recent findings on how quantum tunneling of hydrons through graphene could account for the high hydron selectivity of graphene.
Maruyama, Yu; Sugiyama, Tomoyuki*; Shimada, Asako; Lind, T.*; Bentaib, A.*; Sogalla, M.*; Pellegrini, M.*; Albright, L.*; Clayton, D.*
Proceedings of 20th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-20) (Internet), p.4782 - 4795, 2023/08
Shimomura, Koichiro*; Koda, Akihiro*; Pant, A. D.*; Natori, Hiroaki*; Fujimori, Hiroshi*; Umegaki, Izumi*; Nakamura, Jumpei*; Tampo, Motonobu*; Kawamura, Naritoshi*; Teshima, Natsuki*; et al.
Journal of Physics; Conference Series, 2462, p.012033_1 - 012033_5, 2023/03
Times Cited Count:0 Percentile:0.2(Physics, Applied)Watabe, Hiroshi*; Sato, Tatsuhiko; Yu, K. N.*; Zivkovic, M.*; Krstic, D.*; Nikezic, D.*; Kim, K. M.*; Yamaya, Taiga*; Kawachi, Naoki*; Tanaka, Hiroki*; et al.
Radiation Protection Dosimetry, 13 Pages, 2023/00
Times Cited Count:0 Percentile:0.01(Environmental Sciences)Previously, we have developed DynamicMC for modelling relative movement of ORNL phantom in a radiation field for MCNP. Using this software, 3-dimensional dose distributions in a phantom irradiated by a certain mono-energetic source can be deduced through its graphical user interface (GUI). In this study, we extended DynamicMC to be used in combination with the PHITS by providing it with a higher flexibility for dynamic movement for a less sophisticated anthropomorphic phantom. We anticipate that the present work and the developed open-source tools will be in the interest of nuclear radiation physics community for research and teaching purposes.
Sato, Takumi; Nagae, Yuji; Kurata, Masaki; Quaini, A.*; Guneau, C.*
CALPHAD; Computer Coupling of Phase Diagrams and Thermochemistry, 79, p.102481_1 - 102481_11, 2022/12
Times Cited Count:0 Percentile:0.01(Thermodynamics)Maurer, C.*; Galmarini, S.*; Solazzo, E.*; Kumierczyk-Michulec, J.*; Bar, J.*; Kalinowski, M.*; Schoeppner, M.*; Bourgouin, P.*; Crawford, A.*; Stein, A.*; et al.
Journal of Environmental Radioactivity, 255, p.106968_1 - 106968_27, 2022/12
Times Cited Count:2 Percentile:14.8(Environmental Sciences)After performing multi-model exercises in 2015 and 2016, a comprehensive Xe-133 atmospheric transport modeling challenge was organized in 2019. For evaluation measured samples for the same time frame were gathered from four International Monitoring System stations located in Europe and North America with overall considerable influence of IRE and/or CNL emissions. As a lesion learnt from the 2nd ATM-Challenge participants were prompted to work with controlled and harmonized model set ups to make runs more comparable, but also to increase diversity. Effects of transport errors, not properly characterized remaining emitters and long IMS sampling times (12 to 24 hours) undoubtedly interfere with the effect of high-quality IRE and CNL stack data. An ensemble based on a few arbitrary submissions is good enough to forecast the Xe-133 background at the stations investigated. The effective ensemble size is below five.
Falyouna, O.*; Maamoun, I.; Ghosh, S.*; Malloum, A.*; Othmani, A.*; Eljamal, O.*; Amen, T. W. M.*; Oroke, A.*; Bornman, C.*; Ahmadi, S.*; et al.
Journal of Molecular Liquids, 368, Part B, p.120726_1 - 120726_25, 2022/12
Times Cited Count:5 Percentile:38.46(Chemistry, Physical)Sheng, J.*; Wang, L.*; Candini, A.*; Jiang, W.*; Huang, L.*; Xi, B.*; Zhao, J.*; Ge, H.*; Zhao, N.*; Fu, Y.*; et al.
Proceedings of the National Academy of Sciences of the United States of America, 119(51), p.e2211193119_1 - e2211193119_9, 2022/12
Times Cited Count:3 Percentile:28(Multidisciplinary Sciences)Honda, Maki; Martschini, M.*; Wieser, A.*; Marchhart, O.*; Lachner, J.*; Priller, A.*; Steier, P.*; Golser, R.*; Sakaguchi, Aya*
JAEA-Conf 2022-001, p.85 - 90, 2022/11
Accelerator mass spectrometry (AMS) is an analytical method that combines mass spectrometry with a tandem accelerator, which has been used mainly in nuclear physics experiments. AMS is used to measure radionuclides with half-lives of 10-10 years. For radionuclides with half-lives of this order, the method of measuring their mass is 10-10 times more sensitive than measuring their activity. Because of this advantage, AMS has been widely applied in Earth and planetary sciences, atomic energy research, and other fields. Among the various studies, Wallner et al. (2021, 2016) have achieved excellent work in Earth and planetary sciences. For example, they have attained the ultra-sensitive analysis of Fe and Pu in environmental samples. These are radionuclides produced by rapid-neutron-capture (r-process) nucleosynthesis. Our recent work shows that a new AMS system (VERA, University of Vienna), which combines laser isobaric separation and a typical AMS system, has been successfully applied to the ultra-sensitive determination of Sr and Cs in environment. For Sr in environmental samples, the -ray measurement by the milking of the daughter nuclide Y is still the principal method, which takes 3-6 weeks. The new AMS method has a detection limit of 0.1 mBq, which is comparable to that of -ray measurement, with a more straightforward chemical treatment than -measurement. Our achievement demonstrates that AMS can be a practical new method for determining Sr in the environment.
Hamdani, A.; Abe, Satoshi; Ishigaki, Masahiro; Shibamoto, Yasuteru; Yonomoto, Taisuke
Progress in Nuclear Energy, 153, p.104415_1 - 104415_16, 2022/11
Times Cited Count:3 Percentile:68.71(Nuclear Science & Technology)Nakamura, Hideo; Bentaib, A.*; Herranz, L. E.*; Ruyer, P.*; Mascari, F.*; Jacquemain, D.*; Adorni, M.*
Proceedings of International Conference on Topical Issues in Nuclear Installation Safety; Strengthening Safety of Evolutionary and Innovative Reactor Designs (TIC 2022) (Internet), 10 Pages, 2022/10
Yasuda, Satoshi; Matsushima, Hisayoshi*; Harada, Kenji*; Tanii, Risako*; Terasawa, Tomoo; Yano, Masahiro; Asaoka, Hidehito; Gueriba, J. S.*; Dio, W. A.*; Fukutani, Katsuyuki
ACS Nano, 16(9), p.14362 - 14369, 2022/09
Times Cited Count:12 Percentile:85.62(Chemistry, Multidisciplinary)The fabrication of hydrogen isotope enrichment system is essential for the development of industrial, medical, life science, and nuclear fusion fields, therefore alternative enrichment techniques with high separation factor and economic feasibility have been still explored. Herein, we report the fabrication of heterogeneous electrode with layered structures consisting of palladium and graphene layers for polymer electrolyte membrane electrochemical hydrogen pumping for the hydrogen isotope enrichment. We demonstrated significant bias voltage dependence of hydrogen/deuterium (H/D) separation ability and its high H/D at lower bias voltage. Theoretical analysis also demonstrated that the observed high H/D at low bias voltage stems from hydrogen isotopes tunneling through atomically-thick graphene during the electrochemical reaction, and the bias dependent H/D results in a transition from the quantum tunneling regime to classical over- barrier regime for hydrogen isotopes transfer via the graphene. These findings provide new insight for a novel economical methodology of efficient hydrogen isotope enrichment.
Khemchandani, K. P.*; Martnez Torres, A.*; Kim, S.-H.*; Nam, S.-I.*; Hosaka, Atsushi
Acta Physica Polonica A, 142(3), p.329 - 336, 2022/09
Times Cited Count:0 Percentile:0(Physics, Multidisciplinary)Honda, Maki; Martschini, M.*; Marchhart, O.*; Priller, A.*; Steier, P.*; Golser, R.*; Sato, Tetsuya; Tsukada, Kazuaki; Sakaguchi, Aya*
Analytical Methods, 14(28), p.2732 - 2738, 2022/07
Times Cited Count:2 Percentile:45.92(Chemistry, Analytical)The sensitive Sr analysis with accelerator mass spectrometry (AMS) was developed for the advances of environmental radiology. One advantage of AMS is the ability to analyze various environmental samples with Sr/Sr atomic ratios of 10 in a simple chemical separation. Three different IAEA samples with known Sr concentrations (moss-soil, animal bone, Syrian soil: 1 g each) were analyzed to assess the validity of the chemical separation and the AMS measurement. The Sr measurements were conducted on the AMS system combined with the Ion Laser InterAction MasSpectrometry (ILIAMS) setup at the University of Vienna, which has excellent isobaric separation performance. The isobaric interference of Zr in the Sr AMS was first removed by chemical separation. The separation factor of Zr in two-step column chromatography with Sr resin and anion exchange resin was 10. The Zr remaining in the sample was removed by ILIAMS effectively. This simple chemical separation achieved a limit of detection 0.1 mBq in the Sr AMS, which is lower than typical -ray detection. The agreement between AMS measurements and nominal values for the Sr concentrations of IAEA samples indicated that the new highly-sensitive Sr analysis in the environmental samples with AMS is reliable even for high matrix samples of soil and bone.