Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Iwami, Satone*; Yamashita, Takuma*; Mitsuyasu, Yusuke*; Ono, Kenta*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
KEK Proceedings 2024-6, p.91 - 95, 2024/12
We aim to improve the detection limit of the ESR dosimetry method. In this study, the saturation behavior of each radical was investigated by varying the microwave power during ESR measurement. Based on the difference in spin relaxation time between carbonate radicals and native radicals, it is expected that the signal-to-noise ratio improves and the detection limit can be lowered when the microwave power is increased to 4.0 mW.
Yamashita, Takuma*; Iwami, Satone*; Mitsuyasu, Yusuke*; Ono, Kenta*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
KEK Proceedings 2024-6, p.85 - 90, 2024/12
To clarify the radiation effects of the accident at the TEPCO's Fukushima Daiichi NPP on living organisms, it is important to accurately estimate the dose to each individual. We have developed a multi-component analysis program using random number optimization to extract only the components derived from carbonate radicals from the ESR spectra.
Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.
Radiation Protection Dosimetry, 199(14), p.1620 - 1625, 2023/09
Times Cited Count:1 Percentile:25.62(Environmental Sciences)We have been conducting dose assessments for Japanese macaques captured in Fukushima to reveal radiobiological effects on the low-dose expose animals. To accurately determine the external exposure dose, it is desirable to examine the analysis of the CO radical intensity. We examined ESR spectra of teeth of 10 macaques captured in Fukushima by two spectrum-decomposition algorithms.
Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.
KEK Proceedings 2022-2, p.120 - 125, 2022/11
We investigate the effect of sample's anisotropy and measurement condition to obtain the higher reproducibility for the shape of the ESR spectrum and the intensity of CO radical.
Ishikawa, Ryoya*; Suzuki, Masatoshi*; Kino, Yasushi*; Endo, Satoru*; Nakajima, Hiroo*; Oka, Toshitaka; Takahashi, Atsushi*; Shimizu, Yoshinaka*; Suzuki, Toshihiko*; Shinoda, Hisashi*; et al.
KEK Proceedings 2022-2, p.61 - 66, 2022/11
The balance between oxidative stress and antioxidant activity, which is a defense mechanism against oxidative stress, was investigated in the liver and bladder of wild Japanese macaques captured in Fukushima Prefecture. No significant induction of oxidative stress by exposure to environmental radionuclides after the Fukushima nuclear accident was observed, suggesting that the stress defense mechanism of the organism is activated in some organs.
Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
KEK Proceedings 2021-2, p.91 - 96, 2021/12
We examined whether the ESR dose estimation method could be applied to wild Japanese macaque. In this work, we investigated the enamel preparation protocol and the analytical method of the ESR spectra.
Komatsu, Kazuki*; Iwasaki, Tsugumi*; Murata, Kosuke*; Yamashiro, Hideaki*; Goh, V. S. T.*; Nakayama, Ryo*; Fujishima, Yohei*; Ono, Takumi*; Kino, Yasushi*; Shimizu, Yoshinaka*; et al.
Reproduction in Domestic Animals, 56(3), p.484 - 497, 2021/03
Times Cited Count:13 Percentile:83.05(Agriculture, Dairy & Animal Science)We have established an archive system of livestock and wild animals from the surrounding ex-evacuation zone. Wildlife within the alert zone have been exposed to low-dose-rate (LDR) radiation for a long and continuous time. In this study, we analysed the morphological characteristics of the testes and in vitro fertilization (IVF) capacity of cryopreserved sperm of raccoons from the ex-evacuation zone of the FDNPP accident. This study revealed that the chronic and LDR radiation exposure associated with the FDNPP accident had no adverse effect on the reproductive characteristics and functions of male raccoons.
Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; Osaka, Ken*; et al.
Radiation Measurements, 134, p.106315_1 - 106315_4, 2020/06
Times Cited Count:9 Percentile:65.08(Nuclear Science & Technology)The relationship between the CO radical intensity and the absorbed dose (dose response curve) of tooth enamel of Japanese macaque was observed by electron spin resonance and the detection limit of our system was estimated to be 33.5 mGy, which is comparable to the detection limit for human molar teeth. Using the dose response curve, external exposure dose for seven wild Japanese macaques captured in Fukushima prefecture were examined. The results suggest that the external exposure dose for the wild Japanese macaques were ranged between 45 mGy to 300 mGy.
Ohara, Takashi; Kiyanagi, Ryoji; Oikawa, Kenichi; Kaneko, Koji; Kawasaki, Takuro; Tamura, Itaru; Nakao, Akiko*; Hanashima, Takayasu*; Munakata, Koji*; Moyoshi, Taketo*; et al.
Journal of Applied Crystallography, 49(1), p.120 - 127, 2016/02
Times Cited Count:59 Percentile:96.22(Chemistry, Multidisciplinary)Hazama, Masatoshi*; Abo, Satoshi*; Masuda, Naoyuki*; Wakaya, Fujio*; Onoda, Shinobu; Makino, Takahiro; Hirao, Toshio*; Oshima, Takeshi; Iwamatsu, Toshiaki*; Oda, Hidekazu*; et al.
Proceedings of 10th International Workshop on Radiation Effects on Semiconductor Devices for Space Applications (RASEDA-10) (Internet), p.115 - 118, 2012/12
Tamura, Itaru; Oikawa, Kenichi; Kawasaki, Takuro; Ohara, Takashi; Kaneko, Koji; Kiyanagi, Ryoji; Kimura, Hiroyuki*; Takahashi, Miwako; Kiyotani, Tamiko*; Arai, Masatoshi; et al.
Journal of Physics; Conference Series, 340, p.012040_1 - 012040_4, 2012/02
Times Cited Count:11 Percentile:94.00(Physics, Condensed Matter)Sakaguchi, Yoshifumi; Kira, Hiroshi; Oku, Takayuki; Shinohara, Takenao; Suzuki, Junichi; Sakai, Kenji; Nakamura, Mitsutaka; Aizawa, Kazuya; Arai, Masatoshi; Noda, Yohei; et al.
Journal of Physics; Conference Series, 294(1), p.012017_1 - 012017_7, 2011/06
Times Cited Count:2 Percentile:64.37(Physics, Applied)Sai, Masataka; Hagiwara, Hiroki; Matsushima, Hiroyuki*; Noda, Masatoshi*; Noda, Masaru*; Ando, Kenichi*; Tanaka, Tatsuya*; Ueda, Tadashi*; Honda, Yuko*; Mizuno, Takashi
JAEA-Data/Code 2010-010, 75 Pages, 2010/09
This report compiles data set of the groundwater chemistry obtained at Mizunami Underground Research Laboratory (MIU) between the fiscal year 2004 and the fiscal year 2007. These data includes groundwater chemistry of inflow in the shafts and sampled groundwater in the boreholes, which drilled from sub-stages of MIU and from surface (MSB-2, MSB-4, and MIZ-1). Basic information (e.g. sampling location, sampling date, sampling method, analytical method) are also described in terms of quality control and traceability.
Fujii, Yasuhiko; Arai, Masatoshi; Kadono, Ryosuke*; Kanaya, Toshiji*; Kamiyama, Takashi*; Niimura, Nobuo*; Nojiri, Hiroyuki*; Noda, Yukio*; Yagi, Takehiko*; Yamada, Kazuyoshi*
Kotai Butsuri, 43(7), p.441 - 450, 2008/07
no abstracts in English
Akiyoshi, Kenji*; Mikake, Shinichiro; Kaneda, Tsutomu*; Noda, Masatoshi*
Tonneru Kogaku Hokokushu (CD-ROM), 17, p.105 - 111, 2007/11
The purpose of this study grasps the effect of the solidified shape as the auxiliary method for ground improvement of deep shaft excavation in weathered rock.
Meigo, Shinichiro; Noda, Fumiaki*; Ishikura, Shuichi*; Futakawa, Masatoshi; Sakamoto, Shinichi; Ikeda, Yujiro
Nuclear Instruments and Methods in Physics Research A, 562(2), p.569 - 572, 2006/06
Times Cited Count:20 Percentile:77.82(Instruments & Instrumentation)no abstracts in English
Ohara, Takashi; Kiyanagi, Ryoji; Kawasaki, Takuro; Oikawa, Kenichi; Kaneko, Koji; Tamura, Itaru; Nakao, Akiko*; Hanashima, Takayasu*; Munakata, Koji*; Kimura, Hiroyuki*; et al.
no journal, ,
SENJU is a new single crystal time-of-flight neutron diffractometer installed at BL18 of J-PARC. SENJU is designed for precise crystal and magnetic structure analyses under multiple extreme environments such as low-temperature, high-pressure and high-magnetic field, and also designed for diffraction measurements of small single crystals less than 1.0 mm in volume. We have successfully achieved structure analysis of a laboratory X-ray size (0.1 mm
) single organic crystal, measurement and visualization of a complex-shape diffuse scattering pattern and measurement of higher order magnetic reflections in high-Q region (Q
16
) by using SENJU. Those results show that the performance of SENJU is as we expected.
Kiyanagi, Ryoji; Ohara, Takashi*; Kawasaki, Takuro; Oikawa, Kenichi; Tamura, Itaru; Kaneko, Koji; Hanashima, Takayasu*; Nakao, Akiko*; Munakata, Koji*; Kimura, Hiroyuki*; et al.
no journal, ,
no abstracts in English
Sakaguchi, Yoshifumi; Kira, Hiroshi; Oku, Takayuki; Shinohara, Takenao; Suzuki, Junichi; Sakai, Kenji; Nakamura, Mitsutaka; Arai, Masatoshi; Noda, Yohei; Koizumi, Satoshi; et al.
no journal, ,
no abstracts in English
Oikawa, Kenichi; Ohara, Takashi*; Kiyanagi, Ryoji; Kawasaki, Takuro; Tamura, Itaru; Kaneko, Koji; Nakamura, Tatsuya; Sakasai, Kaoru; Nakao, Akiko*; Hanashima, Takayasu*; et al.
no journal, ,
SENJU, named after the thousand armed Goddess of Mercy, is a single crystal time-of-flight Laue diffractometer proposed to the MLF at J-PARC. The diffractometer is dedicated for precise crystal and magnetic structure analyses under the combined extreme conditions using a small sample less than 1 . TOF-Laue technique coupled with wide area 2D detectors enables the efficient measurements and improves the completeness of the data. A WLSF-type scintillator detector developed for iBIX was modified to meet the requirements of SENJU. Although the construction schedule has been delayed because of the earthquake, on-beam commissioning will start in 2012.