Thermal transient test and strength evaluation of a tubesheet structure made of Mod.9Cr-1Mo steel, 1; Test model design and experimental results

Ando, Masanori; Hasebe, Shinichi; Kobayashi, Sumio; Kasahara, Naoto*; Toyoshi, Akira*; Omae, Takahiro*; Enuma, Yasuhiro*

Nuclear Engineering and Design, 275, p.408 - 421, 2014/08

AA2013-0395.pdf:2.65MB

 Times Cited Count:4 Percentile:31.13(Nuclear Science & Technology)

To clarify the failure mode of a semispherical tubesheet structure originally designed for SG in the JSFR, a cyclic thermal loading test was performed using a tubesheet model test structure. The tubesheet model made of Mod.9Cr-1Mo steel was subjected to 1,873 cycles of severe thermal transient loads using a large-scale sodium loop, in which sodium heated to 600$$^{circ}$$C and 250$$^{circ}$$C was flowed repeatedly with periods for each transient of 2 and 1 h, respectively. After the test, the test model was inspected by PT. Then, observation using a SEM and hardness testing were performed. A thermal-hydraulic analysis was also performed to validate the measured temperature history during the thermal transient. Through these examinations and evaluation with thermal-hydraulic analysis, the manner of failure in the tubesheet under cyclic thermal loading is discussed.

Journal Articles

Thermal transient test and strength evaluation of a tubesheet structure made of Mod.9Cr-1Mo steel, 2; Creep-fatigue strength evaluation

Ando, Masanori; Hasebe, Shinichi; Kobayashi, Sumio; Kasahara, Naoto*; Toyoshi, Akira*; Omae, Takahiro*; Enuma, Yasuhiro*

Nuclear Engineering and Design, 275, p.422 - 432, 2014/08

AA2013-0396.pdf:1.44MB

 Times Cited Count:12 Percentile:67.72(Nuclear Science & Technology)

In this study, the strength of a tubesheet test model simulating a semispherical tubesheet structure subjected to cyclic thermal transients was evaluated using the finite element analysis (FEA). A test model made of Mod.9Cr-1Mo steel was subjected to 1,873 cycles of severe thermal transient loading using a large-scale sodium loop, in which elevated-temperature sodium at 600$$^{circ}$$C and 250$$^{circ}$$C was flowed repeatedly and kept at the final temperature for 2 and 1 h, respectively. Heat transfer analysis and stress analysis were performed using the sodium temperature data measured during the test. Then, the elastic and inelastic stress analysis results were used to investigate the failure mechanism by creep-fatigue damage and evaluate the failure strength. The evaluation based on the results of inelastic analysis estimated the number of cycles to failure within a factor of 3.

Journal Articles

Creep-fatigue evaluation of a structural model made of Mod.9Cr-1Mo steel subjected to the cyclic thermal loading

Ando, Masanori; Hasebe, Shinichi; Kobayashi, Sumio; Kasahara, Naoto*; Toyoshi, Akira*; Omae, Takahiro*; Enuma, Yasuhiro*

Nihon Kikai Gakkai M&M 2013 Zairyo Rikigaku Kanfarensu Koen Rombunshu (CD-ROM), p.OS1510_1 - OS1510_3, 2013/10

To validate the failure mode and assess creep-fatigue damage evaluation, a thick cylinder test model made of Mod.9Cr-1Mo steel was subjected to 1,873 cycles of accelerated thermal transient loading using a large-scale sodium loop through which liquid sodium at 600$$^{circ}$$C and 250$$^{circ}$$C flowed repeatedly, with the period of each transient being 2 h and 1 h, respectively. After completion of the test, liquid penetrant testing, a surface observation and hardness testing were performed to characterize failure mode. Based on the finite element analysis, creep-fatigue life was evaluated by applying the JSME FRs code. The failure cycles evaluated by rules described in the JSME FRs code was shown to have a safety margin of greater than 300 times for this system.

Journal Articles

Thermal transient test and strength evaluation of a thick cylinder model made of Mod.9Cr-1Mo steel

Ando, Masanori; Hasebe, Shinichi; Kobayashi, Sumio; Kasahara, Naoto*; Toyoshi, Akira*; Omae, Takahiro*; Enuma, Yasuhiro*

Nuclear Engineering and Design, 255, p.296 - 309, 2013/02

 Times Cited Count:19 Percentile:81.46(Nuclear Science & Technology)

To verify the failure mode and assess creep-fatigue damage, a thick cylinder test model made of Mod.9Cr-1Mo steel was subjected to 1,873 cycles of accelerated thermal transient loading using a large-scale sodium loop through which liquid sodium at 600 $$^{circ}$$C and 250 $$^{circ}$$C flowed repeatedly, with the period of each transient being 2 h and 1 h, respectively. After completion of the test, the test model was inspected using liquid penetrant testing. Observations using a scanning electron microscope and hardness testing were then performed to characterize creep-fatigue damage in the structural model subjected to cyclic thermal transient loading in a sodium environment. Finite element analysis were performed to evaluate the relationship between creep-fatigue damage and the observed crack conditions.

Journal Articles

Operation of the electrostatic accelerators

Mizuhashi, Kiyoshi; Uno, Sadanori; Okoshi, Kiyonori; Chiba, Atsuya; Yamada, Keisuke; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Sakai, Takuro; Yokota, Wataru; et al.

JAEA-Review 2006-042, JAEA Takasaki Annual Report 2005, P. 197, 2007/02

Three electrostatic accelerators were almost operated smoothly for various experiments in FY 2005. The yearly operation time of each accelerator amounts to 1974, 2359.9, 1859.9 hour for the tandem, the single-ended and the ion implanter, respectively. Main trouble was a short circuit of a part of the ion source in the single-ended accelerator. This lets to the suspension of operation for fifteen days. As features in FY 2005, the generation of the power cut by thunderbolts and large earthquakes were abounding. By this natural force, the Turbo-molecular pump was broken, experiment was interrupted and then the inspection of accelerator facility was carried out every time. New beam acceleration and improvement of each accelerator were carried out.

Journal Articles

Operation of the electrostatic accelerators

Mizuhashi, Kiyoshi; Uno, Sadanori; Okoshi, Kiyonori; Chiba, Atsuya; Yamada, Keisuke; Saito, Yuichi; Ishii, Yasuyuki; Sakai, Takuro; Sato, Takahiro; Yokota, Wataru; et al.

JAEA-Review 2005-001, TIARA Annual Report 2004, P. 371, 2006/01

no abstracts in English

Oral presentation

Operation of the electrostatic accelerators

Mizuhashi, Kiyoshi; Uno, Sadanori; Okoshi, Kiyonori; Chiba, Atsuya; Yamada, Keisuke; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Sakai, Takuro; Yokota, Wataru; et al.

no journal, , 

no abstracts in English

Oral presentation

Operation of the electrostatic accelerators at TIARA

Mizuhashi, Kiyoshi; Uno, Sadanori; Okoshi, Kiyonori; Chiba, Atsuya; Yamada, Keisuke; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Yokota, Wataru; Kitano, Toshihiko*; et al.

no journal, , 

no abstracts in English

9 (Records 1-9 displayed on this page)