Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Higuchi, Yuki*; Yoshimune, Wataru*; Kato, Satoru*; Hibi, Shogo*; Setoyama, Daigo*; Isegawa, Kazuhisa*; Matsumoto, Yoshihiro*; Hayashida, Hirotoshi*; Nozaki, Hiroshi*; Harada, Masashi*; et al.
Communications Engineering (Internet), 3, p.33_1 - 33_7, 2024/02
Nozaki, Hiroshi*; Kondo, Hiroki*; Shinohara, Takenao; Setoyama, Daigo*; Matsumoto, Yoshihiro*; Sasaki, Tsuyoshi*; Isegawa, Kazuhisa*; Hayashida, Hirotoshi*
Scientific Reports (Internet), 13, p.22082_1 - 22082_8, 2023/12
Times Cited Count:0 Percentile:0(Multidisciplinary Sciences)Iwamoto, Osamu; Iwamoto, Nobuyuki; Kunieda, Satoshi; Minato, Futoshi; Nakayama, Shinsuke; Kimura, Atsushi; Nakamura, Shoji; Endo, Shunsuke; Nagaya, Yasunobu; Tada, Kenichi; et al.
EPJ Web of Conferences, 284, p.14001_1 - 14001_7, 2023/05
Times Cited Count:0 Percentile:0.21(Nuclear Science & Technology)Iyota, Muneyoshi*; Matsuda, Tomoki*; Sano, Tomokazu*; Shigeta, Masaya*; Shobu, Takahisa; Yumoto, Hirokatsu*; Koyama, Takahisa*; Yamazaki, Hiroshi*; Semba, Yasunori*; Ohashi, Haruhiko*; et al.
Journal of Manufacturing Processes, 94, p.424 - 434, 2023/05
Times Cited Count:3 Percentile:57.26(Engineering, Manufacturing)Tada, Kenichi; Nagaya, Yasunobu; Taninaka, Hiroshi; Yokoyama, Kenji; Okita, Shoichiro; Oizumi, Akito; Fukushima, Masahiro; Nakayama, Shinsuke
Journal of Nuclear Science and Technology, 21 Pages, 2023/04
Times Cited Count:6 Percentile:98.92(Nuclear Science & Technology)The new version of the Japanese evaluated nuclear data library, JENDL-5, was released in December 2021. This paper demonstrates the validation of JENDL-5 for fission reactor applications. Benchmark calculations are performed with the continuous-energy Monte Carlo codes MVP and MCNP and the deterministic code system MARBLE. The benchmark calculation results indicate that the performance of JENDL-5 for fission reactor applications is better than that of the former library JENDL-4.0.
Iwamoto, Osamu; Iwamoto, Nobuyuki; Kunieda, Satoshi; Minato, Futoshi; Nakayama, Shinsuke; Abe, Yutaka*; Tsubakihara, Kosuke*; Okumura, Shin*; Ishizuka, Chikako*; Yoshida, Tadashi*; et al.
Journal of Nuclear Science and Technology, 60(1), p.1 - 60, 2023/01
Times Cited Count:64 Percentile:99.99(Nuclear Science & Technology)Iwasa, Kazuaki*; Suyama, Kazuya*; Kawamura, Seiko; Nakajima, Kenji; Raymond, S.*; Steffens, P.*; Yamada, Akira*; Matsuda, Tatsuma*; Aoki, Yuji*; Kawasaki, Ikuto; et al.
Physical Review Materials (Internet), 7(1), p.014201_1 - 014201_11, 2023/01
Times Cited Count:2 Percentile:72.03(Materials Science, Multidisciplinary)Yokoyama, Sumi*; Tatsuzaki, Hideo*; Tanimura, Yoshihiko; Yoshitomi, Hiroshi; Hirao, Shigekazu*; Aoki, Katsunori; Tachiki, Shuichi*; Ezaki, Iwao*; Hoshi, Katsuya; Tsujimura, Norio
Journal of Radiological Protection, 42(3), p.031504_1 - 031504_17, 2022/09
Times Cited Count:1 Percentile:31.61(Environmental Sciences)In Japan, the radiation-dose limit for the lens of the eye was revised in April 2021. Consequently, for workers, the numerical values of the equivalent dose to the lens of the eye are equal to those of the effective dose. Radiation workers, radiation safety officers and licensees must comply with regulations related to radiation protection and optimize protection. The new guidelines on dose monitoring of the lens of the eye developed by the Japan Health Physics Society recommend for the dose to be estimated near the eye for accurate estimation, when the dose to the lens approaches or exceeds the management criteria. However, there is limited information regarding the non-uniform exposure of nuclear power plant workers. In this study, the dose equivalents of high-dose-rate workplaces and the personal doses of 88 workers were estimated at four Japanese commercial nuclear power plant sites (RWR: 3 units and BWR: 3 units) and the dose to the lens of the eye and the exposure situations of the workers were analyzed.
Otosaka, Shigeyoshi*; Jeon, H.*; Hou, Y.*; Watanabe, Takahiro; Aze, Takahiro*; Miyairi, Yosuke*; Yokoyama, Yusuke*; Ogawa, Hiroshi*
Nuclear Instruments and Methods in Physics Research B, 527, p.1 - 6, 2022/09
Times Cited Count:0 Percentile:0.02(Instruments & Instrumentation)The measurement the radiocarbon of dissolved organic matter (DOC) in seawater can provide information about a timescale of the dynamics of dissolved organic matter as well as about its sources in the ocean. Due to the low DOC concentration in seawater, in spite of the development of accelerator mass spectrometry, a relatively large volume of seawater (1 L) is required for that analysis. In addition, complicated processing such as UV irradiation that emits high heat is required. In this study, we have developed a safer and easier method to analyze DOC in seawater than the conventional method. A particularly significant change was the adoption of a low-pressure mercury lamp in the decomposition system, which enabled direct decomposition of organic matter at lower temperatures. We also propose a method to quantitatively evaluate the accuracy of this system by analyzing simulated seawater consists of a soluble reference material of organic matter and sodium chloride. This method is expected to be applied not only to carbon isotope ratio analysis but also to analysis of trace elements and isotopes of various dissolved organic substances.
Omasa, Yoshinori*; Takagi, Shigeyuki*; Toshima, Kento*; Yokoyama, Kaito*; Endo, Wataru*; Orimo, Shinichi*; Saito, Hiroyuki*; Yamada, Takeshi*; Kawakita, Yukinobu; Ikeda, Kazutaka*; et al.
Physical Review Research (Internet), 4(3), p.033215_1 - 033215_9, 2022/09
Ohshima, Hiroyuki; Morishita, Masaki*; Aizawa, Kosuke; Ando, Masanori; Ashida, Takashi; Chikazawa, Yoshitaka; Doda, Norihiro; Enuma, Yasuhiro; Ezure, Toshiki; Fukano, Yoshitaka; et al.
Sodium-cooled Fast Reactors; JSME Series in Thermal and Nuclear Power Generation, Vol.3, 631 Pages, 2022/07
This book is a collection of the past experience of design, construction, and operation of two reactors, the latest knowledge and technology for SFR designs, and the future prospects of SFR development in Japan. It is intended to provide the perspective and the relevant knowledge to enable readers to become more familiar with SFR technology.
Tang, J.*; Seo, O.*; Rivera Rocabado, D. S.*; Koitaya, Takanori*; Yamamoto, Susumu*; Namba, Yusuke*; Song, C.*; Kim, J.*; Yoshigoe, Akitaka; Koyama, Michihisa*; et al.
Applied Surface Science, 587, p.152797_1 - 152797_8, 2022/06
Times Cited Count:7 Percentile:77.62(Chemistry, Physical)The hydrogen absorption and diffusion mechanisms on cube-shaped Pd nanoparticles (NPs) which are important hydrogen-storage materials were studied using X-ray photoelectron spectroscopy and DFT calculations. In the surface region, hydrogen absorption showed almost similar behavior regardless of the NPs size. It was found that the octahedral sites are more favorable than the tetrahedral sites for hydrogen occupation. We also clarified that the hydrogen atoms absorbing on the smaller-sized Pd NPs diffuse to the subsurface more actively because of the weakened Pd-H bond by the surface disordering, which plays an important role in hydrogen adsorption at a low H pressure.
Yokoyama, Kenji; Taninaka, Hiroshi
Kaku Deta Nyusu (Internet), (132), p.25 - 33, 2022/06
This article explains the results of integral test of JENDL-5 by benchmark analysis in fast reactor system, which were presented in a special session of the 2022 Spring Annual Meeting of the Atomic Energy Society of Japan (AESJ). The latest version of Japanese evaluated nuclear data library, JENDL-5, was released in December 2021. In order to confirm the applicability of JENDL-5 to the fast reactor system, we conducted a set of benchmark analysis using the integral experiment data included in the fast reactor nuclear design database which is being developed by JAEA. With respect to major nuclear characteristics in the standard fast reactor system, it was confirmed that the ratios of analysis result and experimental result (C/E values) based on JENDL-5 were almost the same as those of JENDL-4.0. In the special session, the results of sensitivity analysis were reported. Since the results have been described in the proceedings of the AESJ meeting, we add the results of the versions under development of JENDL-5 and discuss their relationship with the reported results of sensitivity analysis.
Yokoyama, Kenji; Maruyama, Shuhei; Taninaka, Hiroshi; Oki, Shigeo
JAEA-Data/Code 2021-019, 115 Pages, 2022/03
In JAEA, several versions of unified cross-section set for fast reactors have been developed so far; we have developed a new unified cross-section set ADJ2017R, which is an improved version of the unified cross-section setADJ2017 for fast reactors. The unified cross-section set is used for reflecting information of C/E values (analysis / experiment values) obtained by integral experiment analyses in reactor core design via the cross-section adjustment methodology; the values are stored in the standard database for FBR core design. In the methodology, the cross-section set is adjusted by integrating the information such as uncertainty (covariance) of nuclear data, uncertainty of integral experiment / analysis, sensitivity of integral experiment with respect to nuclear data. ADJ2017R basically has the same performance as ADJ2017, but we conducted an additional investigation on ADJ2017 and revised the following two points. The first is to unify the evaluation method of the correlation coefficient of uncertainty caused by experiments (hereinafter referred to as the experimental correlation coefficient). Because it was found that the common uncertainty used in the evaluation of the experimental correlation coefficient was evaluated by two different methods, the experimental correlation coefficients were revised for all experimental data, and the evaluation method was unified. The second is the review of the integral experiment data used for the cross-section adjustment calculation. It was found that one of the experimental values of composition ratio after irradiation of the Am-243 sample has a problem in uncertainty evaluation because its experimental uncertainty is extremely small compared to the others. The cross-section adjustment calculation was, therefore, redone by excluding the experimental value. In the creation of ADJ2017, a total of 719 data sets were analyzed and evaluated, and eventually adopted 620 integral experimental data sets. In contrast, a total of 61
Yokoyama, Sumi*; Tsujimura, Norio; Hashimoto, Makoto; Yoshitomi, Hiroshi; Kato, Masahiro*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Sekiguchi, Hiroshi*; Koguchi, Yasuhiro*; Ono, Koji*; et al.
Journal of Radiation Protection and Research, 47(1), p.1 - 7, 2022/03
Background: In Japan, new regulations that revise the dose limit for the lens of the eye (the lens), operational quantities, and measurement positions for the lens dose were enforced in April 2021. Based on the international safety standards, national guidelines, the results of the Radiation Safety Research Promotion Fund of the Nuclear Regulatory Authority, and other studies, the Working Group of Radiation Protection Standardization Committee, the Japan Health Physics Society (JHPS) developed a guideline for radiation dose monitoring for the lens. Materials and Methods: The Working Group of the JHPS discussed the criteria of non-uniform exposure and the management criteria set to not exceed the dose limit for the lens. Results and Discussion: In July 2020, the JHPS guideline was published. The guideline consists of three parts: main text, explanations, and 26 questions. In the questions, the corresponding answers were prepared, and specific examples were provided to enable similar cases to be addressed. Conclusion: With the development of guideline on radiation dose monitoring of the lens, radiation managers and workers will be able to smoothly comply with revised regulations and optimise radiation protection.
Yokoyama, Sumi*; Iwai, Satoshi*; Tsujimura, Norio; Hashimoto, Makoto; Yoshitomi, Hiroshi; Kato, Masahiro*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Sekiguchi, Hiroshi*; Koguchi, Yasuhiro*; et al.
Proceedings of 15th International Congress of the International Radiation Protection Association (IRPA-15) (Internet), 8 Pages, 2022/00
Xu, P. G.; Takamura, Masato*; Iwamoto, Chihiro*; Hakoyama, Tomoyuki*; Otake, Yoshie*; Suzuki, Hiroshi
Isotope News, (774), p.7 - 10, 2021/04
no abstracts in English
Kitazato, Kohei*; Milliken, R. E.*; Iwata, Takahiro*; Abe, Masanao*; Otake, Makiko*; Matsuura, Shuji*; Takagi, Yasuhiko*; Nakamura, Tomoki*; Hiroi, Takahiro*; Matsuoka, Moe*; et al.
Nature Astronomy (Internet), 5(3), p.246 - 250, 2021/03
Times Cited Count:43 Percentile:96.93(Astronomy & Astrophysics)Here we report observations of Ryugu's subsurface material by the Near-Infrared Spectrometer (NIRS3) on the Hayabusa2 spacecraft. Reflectance spectra of excavated material exhibit a hydroxyl (OH) absorption feature that is slightly stronger and peak-shifted compared with that observed for the surface, indicating that space weathering and/or radiative heating have caused subtle spectral changes in the uppermost surface. However, the strength and shape of the OH feature still suggests that the subsurface material experienced heating above 300 C, similar to the surface. In contrast, thermophysical modeling indicates that radiative heating does not increase the temperature above 200 C at the estimated excavation depth of 1 m, even if the semimajor axis is reduced to 0.344 au. This supports the hypothesis that primary thermal alteration occurred due to radiogenic and/or impact heating on Ryugu's parent body.
Jee, H.*; Im, S.*; Kanematsu, Manabu*; Suzuki, Hiroshi; Morooka, Satoshi; Koyama, Taku*; Machida, Akihiko*; Bae, S.*
Journal of the American Ceramic Society, 103(12), p.7188 - 7201, 2020/12
Times Cited Count:14 Percentile:65.58(Materials Science, Ceramics)Tsujimura, Norio; Hoshi, Katsuya; Yamazaki, Takumi; Momose, Takumaro; Aoki, Katsunori; Yoshitomi, Hiroshi; Tanimura, Yoshihiko; Yokoyama, Sumi*
KEK Proceedings 2020-5, p.21 - 28, 2020/11