Refine your search:     
Report No.
 - 
Search Results: Records 1-3 displayed on this page of 3
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Determination of tungsten and molybdenum concentrations from an X-ray range spectrum in JET with the ITER-like wall configuration

Nakano, Tomohide; Shumack, A.*; Maggi, C. F.*; Reinke, M.*; Lawson, K.*; Coffey, I.*; P$"u$tterich, T.*; Brezinsek, S.*; Lipschultz, B.*; Matthews, G. F.*; et al.

Journal of Physics B; Atomic, Molecular and Optical Physics, 48(14), p.144023_1 - 144023_11, 2015/07

 Times Cited Count:29 Percentile:82.31(Optics)

The $$mbox{W}^{45+}$$ and $$mbox{W}^{46+}$$ 3p-4d inner shell excitation lines in addition to $$mbox{Mo}^{32+}$$ 2p-3s lines have been identified from the spectrum taken by an upgraded high-resolution X-ray spectrometer. It is found from analysis of the absolute intensities of the $$mbox{W}^{46+}$$ and $$mbox{Mo}^{32+}$$ lines that W and Mo concentrations are in the range of $$sim10^{-5}$$ and $$sim10^{-6}$$, respectively, with a ratio of $$sim$$ 5% for ELMy H-mode plasmas with a plasma current of 2.0- 2.5 MA, a toroidal magnetic field of 2.7 T and a neutral beam injection power of 14-18 MW. For the purpose of checking self-consistency, it is confirmed that the W concentration determined from the $$mbox{W}^{45+}$$ line is in agreement with that from the $$mbox{W}^{46+}$$ line within 20% and that the plasma effective charge determined from the continuum of the first order reflection spectrum is also in agreement with that from the second order within 50%. Further, the determined plasma effective charge is in agreement with that determined from a visible spectroscopy, confirming that the sensitivity of the X-ray spectrometer is valid and that probably the W and the Mo concentrations are also valid.

Journal Articles

Determination of tungsten and molybdenum concentrations from an X-ray range spectrum in JET

Nakano, Tomohide; Shumack, A. E.*; Maggi, C.*; Reinke, M.*; Lawson, K. D.*; P$"u$tterich, T.*; Brezinsek, S.*; Lipschultz, B.*; Matthews, G.*; Chernyshova, M.*; et al.

Europhysics Conference Abstracts (Internet), 38F, p.P1.019_1 - P1.019_4, 2014/06

no abstracts in English

Oral presentation

Determination of tungsten and molybdenum concentrations from an X-ray range spectrum in JET

Nakano, Tomohide; Shumack, A.*; Maggi, C. F.*; Reinke, M.*; Lawson, K.*; P$"u$tterich, T.*; Brezinsek, S.*; Lipschultz, B.*; Matthews, G. F.*; Chernyshova, M.*; et al.

no journal, , 

In an European tokamak device, JET, an existing high-resolution X-ray crystal spectrometer was upgraded together with installation of the W divertor for the purpose of monitoring the W density in the core plasma. We have identified W$$^{46+}$$, W$$^{45+}$$ and Mo$$^{32+}$$ lines by comparing the spectrum observed by this spectrometer and that calculated by an atomic structure code. Further, from the intensities of these spectral lines, the W density and the Mo density over an electron density were determined to be $$10^{-5}$$ and $$10^{-7}$$, respectively. The determined W density was in good agreement with that from another spectrometer. In addition, the plasma effective charge evaluated from the continuum intensity observed by the X-ray spectrometer was in agreement with that from a visible spectrometer within a factor of three. From these agreements, it is probable that the determined W and Mo density are valid. In contrast, the determined W density is only 15% compared with that from an soft X-ray array measurement. This inconsistency will be investigated in the near future.

3 (Records 1-3 displayed on this page)
  • 1