Suzuki, Kenji*; Miura, Yasufumi*; Shiro, Ayumi*; Toyokawa, Hidenori*; Saji, Choji*; Shobu, Takahisa; Morooka, Satoshi
Zairyo, 72(4), p.316 - 323, 2023/04
Suzuki, Kenji*; Kura, Komoe*; Miura, Yasufumi*; Shiro, Ayumi*; Toyokawa, Hidenori*; Saji, Choji*; Kajiwara, Kentaro*; Shobu, Takahisa
Zairyo, 71(12), p.1005 - 1012, 2022/12
This paper describes a stress measurement from a welded part of an austenitic stainless steel using synchrotron X-rays. Difficulty measuring the X-ray stress of the welded part is caused by the broadening of the diffraction spot in the radial and circumferential directions. The bending strains of the rectangular bar made of the welded part were measured using synchrotron white X-rays and the double exposure method. To improve the energy resolution, monochromatic synchrotron X-ray of 70 keV was used. The diffraction pattern showed the sharp arc like a pattern from texture material. The diffraction profile was obtained from the integral of the diffraction intensity in the direction of the circumference. The diffraction angle was determined using the double exposure method. As a result, the distribution of the residual stresses of the welded part could be measured.
Suzuki, Kenji*; Yamada, Minami*; Shiro, Ayumi*; Shobu, Takahisa; Toyokawa, Hidenori*; Saji, Choji*
Zairyo, 71(4), p.347 - 353, 2022/04
We have already succeeded in the residual stress of aluminum alloys using the double exposure method (DEM) with 30 keV synchrotron radiation X-rays. However, the DEM has not be applied in the range of high-energy synchrotron X-rays. In this study, the stress measurements of a shrink-fitted ring using the DEM with synchrotron monochromatic X-rays beyond about 70 keV were performed. A CdTe pixel detector and a CCD camera were used as a detector. The shrink-fitted specimen of SUS304 was quasi-coarse grains of 43 micro-meters, and the diffraction rings were spotty. Despite quasi-coarse grains, it was possible to measure the stresses of the shrink-fitted specimen using the DEM. As a result, the DEM is excellent method to measures the stress for coarse grained materials. In addition, it is better to make the length between the detection positions longer to improve precision of the DEM. On the other hand, it was ineffective to increase the positions of detection.
Suzuki, Kenji*; Shiro, Ayumi*; Toyokawa, Hidenori*; Saji, Choji*; Shobu, Takahisa
Quantum Beam Science (Internet), 4(3), p.25_1 - 25_14, 2020/09
It is difficult to evaluate stress by the strain scanning method using a conventional diffractometer and a point detector since the two-dimensional diffraction pattern of a material composed of coarse grains does not have a ring but a spotty. To solve this problem, we proposed a double exposure method using a two-dimensional detector and monochromatized X-rays. In this study, we have developed a technique to apply that technique to white X-rays. The diffraction obtained by irradiating white X-rays for a material with of coarse grains becomes a Laue spot. Therefore, we have carried out developing a CdTe pixel two-dimensional detector that can limit the energy to be detected, and we evaluated the stress using that detector. As a result, we succeeded to measure the strain distribution of a bending specimen made to austenitic stainless steel. In the future, we would like to improve this technology and apply it to actual machine materials.
Toyokawa, Hidenori*; Saji, Choji*; Kawase, Morihiro*; Wu, S.*; Hurukawa, Yukihito*; Kajiwara, Kentaro*; Sato, Masugu*; Hirono, Toko*; Shiro, Ayumi*; Shobu, Takahisa; et al.
Journal of Instrumentation (Internet), 12(1), p.C01044_1 - C01044_7, 2017/01
Times Cited Count:4 Percentile:22.63(Instruments & Instrumentation)We have been developing CdTe pixel detectors combined with a Schottky diode sensor and photon-counting ASICs. The hybrid pixel detector was designed with a pixel size of 200 micro-meter by 200 micro-meter and an area of 19 mm by 20 mm or 38.2 mm by 40.2 mm. The photon-counting ASIC, SP8-04F10K, has a preamplifier, a shaper, 3-level window-type discriminators and a 24-bits counter in each pixel. The single-chip detector with 100 by 95 pixels successfully operated with a photon-counting mode selecting X-ray energy with the window comparator and stable operation was realized at 20C. We have performed a feasibility study for a white X-ray microbeam experiment. Laue diffraction patterns were measured during the scan of the irradiated position in a silicon steel sample. The grain boundaries were identified by using the differentials between adjacent images at each position.
Suzuki, Kenji*; Miura, Yasufumi*; Shiro, Ayumi*; Toyokawa, Hidenori*; Saji, Choji*; Morooka, Satoshi; Shobu, Takahisa