Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Matsuda, Norihiro; Sasamoto, Nobuo
Radiation Protection Dosimetry, 140(3), p.211 - 217, 2010/08
Times Cited Count:1 Percentile:9.64(Environmental Sciences)Semi-empirical formulas for the duct streaming of -rays are useful as ever for application to practical shielding designs. Based on the algorithm of the DIN's formula, a new semi-empirical formula has been developed. Major improvements are the re-definition of the duct leg region, introduction of the
-ray energy dependent total dose albedo and formulation for the bend duct with arbitrary flexion angles. Validity of the formula was verified through benchmark analyses of
-ray streaming through three-legged duct with rectangular bend and the one with the flexion angle of 137
.
Nakashima, Hiroshi; Nakane, Yoshihiro; Masukawa, Fumihiro; Matsuda, Norihiro; Oguri, Tomomi*; Nakano, Hideo*; Sasamoto, Nobuo*; Shibata, Tokushi*; Suzuki, Takenori*; Miura, Taichi*; et al.
Radiation Protection Dosimetry, 115(1-4), p.564 - 568, 2005/12
Times Cited Count:8 Percentile:48.41(Environmental Sciences)The High Intensity Proton Accelerator Project, named as J-PARC, is in progress, aiming at studies on the latest basic science and the advancing nuclear technology. In the project, the high-energy proton accelerator complex of the world highest intensity is under construction. In order to establish a reasonable shielding design, both simplified and detailed design methods were used in the shielding design of J-PARC. This paper reviews the present status of the radiation safety design study for J-PARC.
Yachi, Shigeyasu; Nakamura, Jinichi; Amaya, Masaki; Nakajima, Kunihisa; Komuro, Yuichi; Nakajima, Katsuaki*; Kobayashi, Yasuhiko; Sato, Tadashi*; Suga, Shinichi*; Noguchi, Hiroshi; et al.
JAERI-Review 2004-020, 61 Pages, 2004/09
This report provides an example of answers to the problems of the 36th Examination for the Chief Engineer of Nuclear Fuel. This examination was done as a national qualification in March 2004. Brief explanations or references are added to some answers.
Nakano, Hideo*; Masukawa, Fumihiro; Nakashima, Hiroshi; Sasamoto, Nobuo*; Tayama, Ryuichi*; Handa, Hiroyuki*; Hayashi, Katsumi*
Journal of Nuclear Science and Technology, 41(Suppl.4), p.50 - 53, 2004/03
In order to estimate accuracy of the various calculation methods for the neutron streaming through a maze and duct in proton accelerator facilities, we performed benchmark analyses by using the radiation shielding design codes. According to the results of the benchmark analyses, it is concluded that NMTC/MCNP, MCNPX and DUCT-III are applicable to actual calculation of the duct-streaming radiations for J-PARC.
Matsuda, Norihiro; Nakashima, Hiroshi; Kasugai, Yoshimi; Sasamoto, Nobuo*; Kinno, Masaharu*; Kitami, Takayuki; Ichimura, Takahito; Hori, Junichi*; Ochiai, Kentaro; Nishitani, Takeo
Journal of Nuclear Science and Technology, 41(Suppl.4), p.74 - 77, 2004/03
In high power proton accelerator facilities, concrete shield can be highly activated, which makes maintenance work quite difficult. So, a low-activationized concrete (limestone concrete) is to be partially adopted as a concrete shield for Japan Proton Accelerator Research Complex (J-PARC) aiming at reducing -ray exposure dose during maintenance period. A new quantity,
Na-equivalent, was introduced as a criterion to assure effectiveness of the low-activationized concrete. In order of its verification, powdered low-activationized concrete and ordinary one were irradiated using FNS at JAERI. The measurements were analyzed by a shielding design code system being used for J-PARC, showing that the calculations reproduce the measured induced activity within a factor of 2. Furthermore, by using the same code system,
-ray exposure dose was calculated for the configuration of J-PARC to find out that
-ray exposure dose by the low-activationized concrete was about 10 times lower than that by the ordinary concrete in a period of less than a few days after operation.
Masukawa, Fumihiro; Nakano, Hideo*; Nakashima, Hiroshi; Sasamoto, Nobuo; Tayama, Ryuichi*; Hayashi, Katsumi*; Shin, Kazuo*
Journal of Nuclear Science and Technology, 41(Suppl.4), p.46 - 49, 2004/03
A simple design code for duct-streaming radiations, DUCT-III was applied to the analyses of the streamed neutron spectra measured at TIARA labyrinth with two bends. The code satisfactorily reproduced the measured neutron energy spectra and the Monte Carlo calculations, except that every calculation overestimated the measured thermal components by factor of 2 or 3.
Masukawa, Fumihiro; Nakano, Hideo*; Nakashima, Hiroshi; Sasamoto, Nobuo; Tayama, Ryuichi*; Handa, Hiroyuki*; Hayashi, Katsumi*; Hirayama, Hideo*; Shin, Kazuo*
JAERI-Tech 2003-018, 42 Pages, 2003/03
no abstracts in English
Nakane, Yoshihiro; Harada, Yasunori; Sakamoto, Yukio; Oguri, Tomomi*; Yoshizawa, Michio; Takahashi, Fumiaki; Ishikura, Takeshi*; Fujimoto, Toshiaki*; Tanaka, Susumu; Sasamoto, Nobuo
JAERI-Tech 2003-011, 37 Pages, 2003/03
no abstracts in English
Masukawa, Fumihiro; Nakashima, Hiroshi; Sasamoto, Nobuo; Nakano, Hideo*; Tayama, Ryuichi*
Journal of Nuclear Science and Technology, 39(Suppl.2), p.1268 - 1271, 2002/08
no abstracts in English
Nakane, Yoshihiro; Masukawa, Fumihiro; Oguri, Tomomi*; Nakashima, Hiroshi; Abe, Teruo*; Sasamoto, Nobuo
Journal of Nuclear Science and Technology, 39(Suppl.2), p.1260 - 1263, 2002/08
no abstracts in English
Sasamoto, Nobuo; Nakashima, Hiroshi; Hirayama, Hideo*; Shibata, Tokushi*
Journal of Nuclear Science and Technology, 39(Suppl.2), p.1264 - 1267, 2002/08
no abstracts in English
Masumura, Tomomi*; Nakashima, Hiroshi; Nakane, Yoshihiro; Sasamoto, Nobuo
JAERI-Data/Code 2000-026, 40 Pages, 2000/06
no abstracts in English
Nakashima, Hiroshi; Sasamoto, Nobuo; Sakamoto, Yukio; Kusano, Joichi; Hasegawa, Kazuo; Handa, Hiroyuki*; Hayashi, Katsumi*; Yamada, Kobun*; Abe, Teruo*
Journal of Nuclear Science and Technology, 37(Suppl.1), p.870 - 874, 2000/03
no abstracts in English
Asano, Yoshihiro; Sasamoto, Nobuo
Radiation Protection Dosimetry, 82(3), p.167 - 174, 1999/00
Times Cited Count:9 Percentile:56.59(Environmental Sciences)no abstracts in English
Asano, Yoshihiro; Sasamoto, Nobuo
JAERI-Tech 98-009, 90 Pages, 1998/03
no abstracts in English
Harada, Yasunori; Sasamoto, Nobuo; Sakamoto, Yukio; Kurosawa, Naohiro*;
JAERI-Data/Code 97-013, 196 Pages, 1997/03
no abstracts in English
Asano, Yoshihiro; Sasamoto, Nobuo
IRPA9: 1996 International Congress on Radiation Protection, Proceedings, p.4_582 - 4_585, 1996/04
no abstracts in English
Asano, Yoshihiro; Sasamoto, Nobuo; Nakane, Yoshihiro; Nakashima, Hiroshi; Sakamoto, Yukio; Tanaka, Shunichi; Namito, Yoshihito*; Ban, Shuichi*; Hirayama, Hideo*; Nariyama, Nobuteru*
IRPA9: 1996 International Congress on Radiation Protection, Proceedings, p.4_253 - 4_255, 1996/00
no abstracts in English
Namito, Yoshihito*; Ban, Shuichi*; Hirayama, Hideo*; Nariyama, Nobuteru*; Nakashima, Hiroshi; Nakane, Yoshihiro; Sakamoto, Yukio; Sasamoto, Nobuo; Asano, Yoshihiro; Tanaka, Shunichi
Physical Review A, 51(4), p.3036 - 3043, 1995/04
Times Cited Count:54 Percentile:90.85(Optics)no abstracts in English
; Sakamoto, Yukio; Tanaka, Shunichi; ; Fukahori, Tokio; ; Sasamoto, Nobuo; Tanaka, Susumu; Nakamura, Takashi*; Shin, Kazuo*; et al.
JAERI-Data/Code 94-012, 90 Pages, 1994/09
no abstracts in English