Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.
Radiation Protection Dosimetry, 199(14), p.1620 - 1625, 2023/09
Times Cited Count:0 Percentile:0.01(Environmental Sciences)We have been conducting dose assessments for Japanese macaques captured in Fukushima to reveal radiobiological effects on the low-dose expose animals. To accurately determine the external exposure dose, it is desirable to examine the analysis of the CO radical intensity. We examined ESR spectra of teeth of 10 macaques captured in Fukushima by two spectrum-decomposition algorithms.
Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.
KEK Proceedings 2022-2, p.120 - 125, 2022/11
We investigate the effect of sample's anisotropy and measurement condition to obtain the higher reproducibility for the shape of the ESR spectrum and the intensity of CO radical.
Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
KEK Proceedings 2021-2, p.91 - 96, 2021/12
We examined whether the ESR dose estimation method could be applied to wild Japanese macaque. In this work, we investigated the enamel preparation protocol and the analytical method of the ESR spectra.
Koarai, Kazuma; Matsueda, Makoto; Aoki, Jo; Yanagisawa, Kayo*; Terashima, Motoki; Fujiwara, Kenso; Kino, Yasushi*; Oka, Toshitaka; Takahashi, Atsushi*; Suzuki, Toshihiko*; et al.
Journal of Analytical Atomic Spectrometry, 36(8), p.1678 - 1682, 2021/08
Times Cited Count:5 Percentile:55.72(Chemistry, Analytical)Rapid analysis of Sr in bone and tooth samples of cattle were achieved by an inductively coupled plasma mass spectrometry (ICP-MS) coupled with mass shift and solid phase extraction techniques. Limit of detection (LOD) in the ICP-MS measurement of 0.1 g samples was lower than that of the radioactivity measurement. Analytical time of the ICP-MS method was reduced from 20 days to 11 hours, compared with the radiometric method. Therefore, the ICP-MS method can be rapid and useful procedure of Sr in small bone and tooth samples derived from terrestrial animals.
Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; Osaka, Ken*; et al.
Radiation Measurements, 134, p.106315_1 - 106315_4, 2020/06
Times Cited Count:5 Percentile:53.85(Nuclear Science & Technology)The relationship between the CO radical intensity and the absorbed dose (dose response curve) of tooth enamel of Japanese macaque was observed by electron spin resonance and the detection limit of our system was estimated to be 33.5 mGy, which is comparable to the detection limit for human molar teeth. Using the dose response curve, external exposure dose for seven wild Japanese macaques captured in Fukushima prefecture were examined. The results suggest that the external exposure dose for the wild Japanese macaques were ranged between 45 mGy to 300 mGy.
Sekine, Mariko*; Suzuki, Hiroshi; Kanematsu, Manabu*
Konkurito Kogaku Nenji Rombunshu (DVD-ROM), 40(1), p.1545 - 1550, 2018/07
no abstracts in English
Koyama, Taku*; Ueno, Kazuki*; Sekine, Mariko*; Matsumoto, Yoshihiro*; Kai, Tetsuya; Shinohara, Takenao; Iikura, Hiroshi; Suzuki, Hiroshi; Kanematsu, Manabu*
Materials Research Proceedings, Vol.4, p.155 - 160, 2018/05
Times Cited Count:0 Percentile:0.18(Materials Science, Characterization & Testing)Yano, Yasuhide; Otsuka, Satoshi; Yamashita, Shinichiro; Ogawa, Ryuichiro; Sekine, Manabu; Endo, Toshiaki; Yamagata, Ichiro; Sekio, Yoshihiro; Tanno, Takashi; Uwaba, Tomoyuki; et al.
JAEA-Research 2013-030, 57 Pages, 2013/11
It is necessary to develop the fast reactor core materials, which can achieve high-burnup operation improving safety and economical performance. Ferritic steels are expected to be good candidate core materials to achieve this objective because of their excellent void swelling resistance. Therefore, oxide dispersion strengthened (ODS) ferritic steel and 11Cr-ferritic/martensitic steel (PNC-FMS) have been respectively developed for cladding and wrapper tube materials in Japan Atomic Energy Agency. In this study, the effects of fast neutron irradiation on mechanical properties and microstructure of 9Cr-and 12Cr-ODS steel claddings for fast reactor were investigated. Specimens were irradiated in the experimental fast reactor Joyo using the CMIR-6 at temperatures between 420 and 835C to fast neutron doses ranging from 16 to 33 dpa. The post-irradiation ring tensile tests were carried out at irradiation temperatures.
Yamashita, Shinichiro; Sekine, Manabu*; Akasaka, Naoaki
Materia, 47(12), P. 624, 2008/12
no abstracts in English
Donomae, Takako; Tachi, Yoshiaki; Sekine, Manabu*; Morohashi, Yuko; Akasaka, Naoaki; Onose, Shoji
Journal of the Ceramic Society of Japan, 115(1345), p.551 - 555, 2007/09
Times Cited Count:4 Percentile:29.01(Materials Science, Ceramics)Use of moderator materials in Fast Breeder Reactor (FBR) is effective for transmutation technology, and BC is one of the candidates. Up to now, the behavior of BC as the Control rod material is well known, but that of BC is hardly investigated. In this paper, the radiation effects of BC pellets, neutron irradiated in the experimental fast reactor JOYO were studied. From the experimental results, it was observed that no macro-cracks were recognized in the irradiated BC pellets. But, bubble nucleation was found in grain and along grain boundaries of BC. And, it was shown that the conductivity of BC was higher than that of BC. During the annealing from room temperature to 1400C, three recovery stages were found on thermal conductivity. It was suggested that, the recovery of BC was related to the dispersion behavior of helium. Judging from these results, as BC was mechanically more stable compared with BC under irradiation, it was shown that BC had high applicability for a moderator.
Donomae, Takako; Tachi, Yoshiaki; Onose, Shoji; Matsumoto, Shinichiro; Ito, Masahiko; Sekine, Manabu*
no journal, ,
no abstracts in English
Yamashita, Shinichiro; Tachi, Yoshiaki; Akasaka, Naoaki; Sekine, Manabu*
no journal, ,
no abstracts in English
Yano, Yasuhide; Yamashita, Shinichiro; Sekine, Manabu*; Yoshitake, Tsunemitsu; Akasaka, Naoaki
no journal, ,
no abstracts in English
Yamashita, Shinichiro; Sekine, Manabu*; Tachi, Yoshiaki; Akasaka, Naoaki; Nishinoiri, Kenji; Takahashi, Heishichiro
no journal, ,
no abstracts in English
Ueno, Kazuki*; Suzuki, Hiroshi; Koyama, Taku*; Sekine, Mariko*; Nishio, Yuhei*; Kanematsu, Manabu*
no journal, ,
no abstracts in English
Sekine, Mariko*; Suzuki, Hiroshi; Koyama, Taku*; Ueno, Kazuki*; Nishio, Yuhei*; Kanematsu, Manabu*
no journal, ,
no abstracts in English
Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Ono, Takumi*; Tamaki, Hiroaki*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.
no journal, ,
Releases of the radioactive materials from the Fukushima Daiichi Nuclear Power Plant accident result in an ionization exposure to people and animals, the precise dosimetry is required. To estimate the external dose due to the accident, we utilize electron spin resonance (ESR) spectroscopy which is a powerful tool for the dosimetry of external dose. The detection limit of this technique was 146 mGy, so that we have to improve the detection limit for the precise dosimetry. In this work, we developed a novel enamel-dentine separation technique and improved the detection limit down to 43 mGy, and estimated the external dose for Japanese macaque and Procyon lotor collected in Fukushima prefecture.
Koarai, Kazuma; Matsueda, Makoto; Fujiwara, Kenso; Ono, Takumi*; Kino, Yasushi*; Oka, Toshitaka; Okutsu, Kenichi*; Takahashi, Atsushi*; Suzuki, Toshihiko*; Shimizu, Yoshinaka*; et al.
no journal, ,
We have investigated incorporation of Sr and Cs in teeth of cattle and otoliths of fish. Specific activity of Sr in the dentin tissue was higher than that in the enamel tissue. The result shows change of Sr incorporation in cattle even within a tooth. Concentrations of stable Sr and Cs were 94 ppm and 3 ppb. Distributions of stable Sr and Cs were uniform in the otolith of fish. If distribution of Sr and Cs in the otolith was measured, change of Sr and Cs incorporation into the fish would be found. These findings suggest that distribution patterns of Sr and Cs in the environment could be estimated from distribution of the radionuclides in the tooth and otolith.
Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Ono, Takumi*; Tamaki, Hiroaki*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
no journal, ,
Release of the radioactive materials from Fukushima Daiichi Nuclear Power Plant accident results in a long-term low dose rate ionization exposure to wild animals. The biological effects of the wild animal do not show a clear correlation with the external dose, which is estimated from the external dose rate of the captured point of the animal, a precise external dose estimation using ESR and tooth enamel is required instead of using the external dose rate. In this work, we attempted to estimate the external dose of wild Japanese macaque and Procyon lotor captured in the high dose rate area.
Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; Osaka, Ken*; et al.
no journal, ,
Due to the Fukushima Daiichi Nuclear Power Plant accident, the exposure dose estimation for human is examined by the whole body counter or by the Fukushima Health Management Survey, however, the precise estimated dose cannot obtained by such methods. We applied electron spin resonance (ESR) dosimetry for the external dose estimation using tooth enamel of human/animal. As we reported last year, we improved the detection limit of ESR dosimetry down to 43 mGy. We used this improved ESR dosimetry system and attempted to estimate the external dose of wild Japanese macaque capture in Fukushima prefecture, however, the metal component which may obstruct the ESR measurement was observed, so that we cannot estimate the external dose. In this work, we investigated how to remove such metal components, obtain the clear ESR spectrum, and estimate the external dose.