Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 223

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of a radiation tolerant laser-induced breakdown spectroscopy system using a single crystal micro-chip laser for remote elemental analysis

Tamura, Koji; Nakanishi, Ryuzo; Oba, Hironori; Karino, Takahiro; Shibata, Takuya; Taira, Takunori*; Wakaida, Ikuo

Journal of Nuclear Science and Technology, 8 Pages, 2024/00

 Times Cited Count:0 Percentile:0.01(Nuclear Science & Technology)

Journal Articles

Structural changes of polystyrene particles in subcritical and supercritical water revealed by in situ small-angle neutron scattering

Shibata, Motoki*; Nakanishi, Yohei*; Abe, Jun*; Arima, Hiroshi*; Iwase, Hiroki*; Shibayama, Mitsuhiro*; Motokawa, Ryuhei; Kumada, Takayuki; Takata, Shinichi; Yamamoto, Katsuhiro*; et al.

Polymer Journal, 55(11), p.1165 - 1170, 2023/11

 Times Cited Count:1 Percentile:51.7(Polymer Science)

Journal Articles

Operation status of the J-PARC high-intensity RF-driven negative hydrogen ion source

Shinto, Katsuhiro; Okoshi, Kiyonori; Shibata, Takanori*; Nammo, Kesao*; Kawai, Isao*; Ikegami, Kiyoshi*; Ueno, Akira

Proceedings of 20th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.928 - 931, 2023/11

J-PARC initiated the operation of the high-intensity rf-driven negative hydrogen (H$$^-$$) ion source in 2014 autumn. The ion source produces the H$$^-$$ beam with the beam current of 60 mA and the beam energy of 50 keV in order to inject the H$$^-$$ beam into the 3 GeV RCS with the beam current of 50 mA and the beam energy of 400 MeV from the J-PARC linac. We have achieved the longest continuous operation time of 4001 hours in the previous (2021/2022) campaign. The 2022/2023 campaign was the first time that the continuous operation of the H$$^-$$ ion source without any exchanges of the ion source until the end of the campaign was examined. We present the operation status of the J-PARC H$$^-$$ ion source in this campaign as well as the status of the J-PARC-made internal antenna test.

Journal Articles

Design of a matching circuit for a high-intensity negative hydrogen ion source driving with 324 MHz RF power source

Shinto, Katsuhiro; Shibata, Takanori*; Wada, Motoi*

Proceedings of 20th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.392 - 395, 2023/11

Negative hydrogen (H$$^-$$) ion sources which are used at high-intensity proton accelerator facilities such as J-PARC or neutral beam injection system for plasma heating in the fusion devices such as ITER produce plasmas by using RF sources driving with the frequency of 1-2 MHz. We have shown that the H$$^-$$ beams extracted from the RF-driven H$$^-$$ ion source with the frequency of several MHz have some fluctuations with the frequency of the fundamental and second harmonics. The reason is that the high plasma density is produced in the ion source with the low driving frequency. Therefore, we propose the driving RF frequency same as the RF sources with that of 324 MHz in the J-PARC linac, which is much higher than the ion plasma frequency, is used for producing the plasma to suppress the H$$^-$$ beam fluctuations. As a first step, we performed a design of a matching circuit for the higher frequency driven H$$^-$$ ion source. We present the background for decision of a new RF amplifier with much higher frequency and the design results.

Journal Articles

Status of the laser stripping of H$$^{-}$$ beam at J-PARC RCS

Saha, P. K.; Harada, Hiroyuki; Yoneda, Hitoki*; Michine, Yurina*; Sato, Atsushi*; Shibata, Takanori*; Kinsho, Michikazu

Proceedings of 20th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.59 - 63, 2023/11

JAEA Reports

Structural investigation of borosilicate glasses by using XAFS measurement in soft X-ray region, 3 (Joint research)

Nagai, Takayuki; Okamoto, Yoshihiro; Yamagishi, Hirona*; Shibata, Daisuke*; Kojima, Kazuo*; Hasegawa, Takehiko*; Sato, Seiichi*; Fukaya, Akane*; Hatakeyama, Kiyoshi*

JAEA-Research 2023-004, 45 Pages, 2023/09

JAEA-Research-2023-004.pdf:6.07MB

The local structure of glass-forming elements and waste elements in borosilicate glasses varies with its chemical composition. In this study, simulated waste glass samples were prepared and the chemical state regarding boron (B), silicon (Si) and waste elements of iron (Fe), cesium (Cs) were estimated by using XAFS measurement in soft X-ray region. To understand the chemical stability of simulated waste glasses, XANES spectra of B K-edge, Fe L$$_{3}$$, L$$_{2}$$-edge, and Cs M$$_{5}$$, M$$_{4}$$-edge were measured on the glass surface exposed to the leachate. As a result, it was found that the glass surface exposed to the leachate was changed and it was difficult to obtain a clear XANES spectrum. From the B K-edge XANES spectra on glass surfaces exposed to the leachate, an increase in three-coordination of B-O (BO$$_{3}$$) and a decrease in four-coordination of B-O (BO$$_{4}$$) were observed compared to the glass surfaces before immersion. The XANES spectra of Fe L$$_{3}$$, L$$_{2}$$-edge, and Cs M$$_{5}$$, M$$_{4}$$-edge show that as the exposure time in the leachate increases, the Cs present on the glass surface dissolves into the leachate. The XANES spectra of Si K-edge were measured on simulated waste glass surfaces before immersion, and it was confirmed that the change in XANES spectra given by Na$$_{2}$$O concentration had a larger effect than the waste component concentration.

Journal Articles

Neutron reflectivity study on the nanostructure of PMMA chains near substrate interfaces based on contrast variation accompanied with small molecule sorption

Shimokita, Keisuke*; Yamamoto, Katsuhiro*; Miyata, Noboru*; Nakanishi, Yohei*; Shibata, Motoki*; Takenaka, Mikihito*; Yamada, Norifumi*; Seto, Hideki*; Aoki, Hiroyuki; Miyazaki, Tsukasa*

Soft Matter, 19(11), p.2082 - 2089, 2023/03

 Times Cited Count:0 Percentile:0(Chemistry, Physical)

Journal Articles

Outgassing characteristics from the J-PARC-made internal antenna for a high-intensity radio-frequency H$$^-$$ ion source

Shinto, Katsuhiro; Shibata, Takanori*; Okoshi, Kiyonori; Nammo, Kesao*; Ikegami, Kiyoshi*; Oguri, Hidetomo

Proceedings of 19th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.675 - 679, 2023/01

In J-PARC, we have been conducting the test of a J-PARC-made internal antenna in order to establish the production method and understand the beam characteristics of the antenna. At this time, we investigated the outgas characteristics during the production of a high-density plasma by using the J-PARC-made antenna. It is confirmed that no remarkable impurities are emitted from the antenna by a residual gas analysis using a quadrupole mass analyzer installed downstream the ion source and a spectroscopic analysis of the plasma in the ion source. It is found that the emittances of the H$$^-$$ beam extracted from the J-PARC radio-frequency H$$^-$$ ion source by using the antenna was similar as those in case by using SNS antenna.

Journal Articles

Evaluation of RF antenna lifetime after long-term operation of J-PARC ion source

Shibata, Takanori*; Ishida, Masaki*; Nammo, Kesao*; Ikegami, Kiyoshi*; Okoshi, Kiyonori; Shinto, Katsuhiro; Oguri, Hidetomo

Proceedings of 19th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.863 - 867, 2023/01

Continuous operation duration of the J-PARC Radio Frequency (RF) ion source has been extended step by step these years for the goal to supply stable beam during the entire period of J-PARC user operation (around 7 months) each year. A 3651 hours (5 months) continuous ion source operation has been achieved from Nov. 2020 to Apr. 2021. As the lifetime of the ion source is mainly limited by failure on the RF antenna coil, detailed evaluation of the antenna surface condition is required to ensure the feasibility of the further extension of the operation time. In the present study, dimension measurements and SEM/EDS analyses were applied to understand the surface discoloration of the RF antenna. The discoloration after the long-term continuous operation is due to deposition of injected cesium (for H$$^-$$ surface production process) and of stainless used steel (Fe, Cr, Ni) from the ion source components sputtered by plasma. The results show that the enamel coating of the RF antenna has not worn out in the long-term continuous operation for several months and, hence, extension of the ion source continuous operation duration can be extended.

Journal Articles

Status of POP demonstration of 400 MeV H$$^{-}$$ laser stripping at J-PARC RCS

Saha, P. K.; Harada, Hiroyuki; Kinsho, Michikazu; Yoneda, Hitoki*; Michine, Yurina*; Sato, Atsushi*; Shibata, Takanori*

Proceedings of 19th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.272 - 276, 2023/01

Journal Articles

A Phoswich alpha/beta detector for monitoring in the site of Fukushima Daiichi Nuclear Power Station

Morishita, Yuki; Takasaki, Koji; Kitayama, Yoshiharu; Tagawa, Akihiro; Shibata, Takuya; Hoshi, Katsuya; Kaneko, Junichi*; Higuchi, Mikio*; Oura, Masatoshi*

Radiation Measurements, 160, p.106896_1 - 106896_10, 2023/01

 Times Cited Count:0 Percentile:0.01(Nuclear Science & Technology)

This study proposes a newly developed phoswich alpha/beta detector that can discriminate alpha and beta particles emitted from the alpha and beta contaminations in the FDNPS site. The phoswich alpha/beta detector is made up of two layers of scintillators that detect alpha and beta particles. The pulse shape discrimination (PSD) method was used to detect alpha particles in high beta particle and high gamma-ray (comparable to gamma-ray dose rate near the FDNPS reactor building) environments. Due to a 23.3% full width at half maximum (FWHM) energy resolution for alpha particles, the detector can be used to distinguish between nuclear fuel materials such as plutonium and its radon progeny (Po-214). Moreover, the detector could distinguish alpha particles from $$^{137}$$Cs gamma rays with a dose rate background up to 9.0 mSv/h. It is the first to demonstrate that the developed phoswich detector can be used to discriminate and measure alpha and beta particles of the actual contaminated FDNPS samples.

Journal Articles

Neutron reflectivity study on the suppression of interfacial water accumulation between a polypropylene thin film and Si substrate using a silane-coupling agent

Shimokita, Keisuke*; Yamamoto, Katsuhiro*; Miyata, Noboru*; Arima-Osonoi, Hiroshi*; Nakanishi, Yohei*; Takenaka, Mikihito*; Shibata, Motoki*; Yamada, Norifumi*; Seto, Hideki*; Aoki, Hiroyuki; et al.

Langmuir, 38(41), p.12457 - 12465, 2022/10

 Times Cited Count:0 Percentile:0(Chemistry, Multidisciplinary)

Journal Articles

Event tree analysis for material relocation on core catcher in a sodium-cooled fast reactor

Yamano, Hidemasa; Kubo, Shigenobu; Kan, Taro*; Shibata, Akihiro*; Hourcade, E.*; Dirat, J. F.*

Proceedings of 29th International Conference on Nuclear Engineering (ICONE 29) (Internet), 10 Pages, 2022/08

In this paper, the approach to event tree development and the scope of the event tree analysis were described with key points on core catcher loading. For the analytical conditions, two core catcher loading conditions were given as bounding and conservative cases. For important heading of the event tree, key important phenomena were included: strong back design, fuel-coolant interaction and quench in the sodium plenum design, jet attack, criticality and coolability on the core catcher. In this paper, preliminary trial quantification was attempted using a probability ranking table which is based on engineering judgement. This event tree analysis has identified the dominant sequence, and clarified the effect of the core catcher loading and effectiveness of design measures. This study suggests that the criticality measure is very important for the core catcher study.

Journal Articles

Revealing the ion dynamics in Li$$_{10}$$GeP$$_{2}$$S$$_{12}$$ by quasi-elastic neutron scattering measurements

Hori, Satoshi*; Kanno, Ryoji*; Kwon, O.*; Kato, Yuki*; Yamada, Takeshi*; Matsuura, Masato*; Yonemura, Masao*; Kamiyama, Takashi*; Shibata, Kaoru; Kawakita, Yukinobu

Journal of Physical Chemistry C, 126(22), p.9518 - 9527, 2022/06

 Times Cited Count:3 Percentile:41.53(Chemistry, Physical)

Journal Articles

Soundness evaluation of J-PARC RF ion source after 5-month continuous operation

Shibata, Takanori*; Okoshi, Kiyonori; Shinto, Katsuhiro; Nammo, Kesao*; Ikegami, Kiyoshi*; Oguri, Hidetomo

Journal of Physics; Conference Series, 2244, p.012041_1 - 012041_5, 2022/04

 Times Cited Count:1 Percentile:0.32(Engineering, Electrical & Electronic)

In the J-PARC user operation from Nov. 2020 - Apr. 2021, continuous operation of J-PARC Radio Frequency (RF) negative hydrogen ion (H$$^-$$) source up to 3,651 hours (5 months) has been achieved. The ion source was operated with the output H$$^-$$ current of 60 mA, the duty factor (for plasma generation) 2% and the input RF power up to 30 kW. After the operation, phase space diagrams at the Radio Frequency Quadrupole (RFQ) entrance were measured by the emittance monitor at the ion source test stand (IS-TS) under the same operation condition as in the J-PARC Linac. Comparison of the phase spaces and the beam emittances between the ion sources in the present and the previous operations shows slight difference. From the direct observation of the antenna coil, no exhaustion or the decrease in the thickness of the enamel coating of the coil have been confirmed. The results indicate the possibility of the next goal of the long-run up to 7 months, which is the same as the full duration of the J-PARC user operation in 1 year.

Journal Articles

Effect of a 2-MHz RF source on the H$$^-$$ beam extracted from an RF-driven high-intensity H$$^-$$ ion source

Shinto, Katsuhiro; Shibata, Takanori*; Wada, Motoi*

Proceedings of 18th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.230 - 233, 2021/10

In most proton accelerator facilities such as J-PARC, SNS, CERN, a H$$^-$$ ion source equipped with a 2-MHz rf driver for plasma generation produces H$$^-$$ beams. We have reported H$$^-$$ beam characteristics extracted from the J-PARC rf-driven high-intensity H$$^-$$ ion source. We have been developing an emittance measurement apparatus equipped with a highly time-resolved data acquisition system in order to observe fluctuation of the beam emittance in association with the frequency of the rf driver. By using this apparatus, we found that the beam emittance is fluctuated with the frequency with the rf driver and higher harmonics. We will show some obtained results of the emittance fluctuation.

Journal Articles

Synchronization system of ion source RF and cavity RF in J-PARC linac

Shibata, Takanori*; Hirano, Koichiro; Hirane, Tatsuya*; Shinto, Katsuhiro; Hayashi, Naoki; Oguri, Hidetomo

Proceedings of 18th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.417 - 421, 2021/10

In J-PARC linac, the operation of an rf-driven high-intensity H$$^-$$ ion source was initiated in 2014. For plasma ignition, the 2-MHz rf amplifier outputs the power of several tens kW. However the rf amplifier for the ion source and those for the accelerating cavities have not been synchronized. As a result, the wave hights in the beam waveforms were different in shot by shot. Therefore, we have developed an synchronization system between the rf system for the ion source and those for the cavity systems and succeeded the same wave hights in the waveforms.

Journal Articles

Recent progress of laser stripping POP demonstration study at J-PARC RCS

Saha, P. K.; Harada, Hiroyuki; Yoneda, Hitoki*; Michine, Yurina*; Fuchi, Aoi*; Sato, Atsushi*; Shibata, Takanori*; Kinsho, Michikazu

Proceedings of 18th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.656 - 660, 2021/10

Journal Articles

High-speed emittance measurements for beams extracted from J-PARC RF ion source

Shibata, Takanori*; Shinto, Katsuhiro; Wada, Motoi*; Oguri, Hidetomo; Ikegami, Kiyoshi*; Okoshi, Kiyonori; Nammo, Kesao*

AIP Conference Proceedings 2373, p.050002_1 - 050002_9, 2021/08

Oscillation of emittance and Twiss parameters in the negative ion beam from the J-PARC 2-MHz RF ion source is measured by applications of a double-slit emittance monitor located at the RFQ (Radio Frequency Quadrupole) entrance. The emittance monitor is equipped with a newly-developed 60 MS/s data acquisition system, so that beam current oscillation in a few MHz can be observed with enough time resolution. From the measurement, it is shown that the beam phase space consists of (1) a DC component in the beam core, (2) a 2-MHz oscillating component which takes place both in the beam core and the halo and (3) a doubled RF frequency (4 MHz) oscillation which slightly exists in the beam halo. The major component is the 2-MHz component, which resultantly decides the beam emittance oscillation frequency. A typical value of the beam emittance in the present experiment is 0.34 $$pi$$ mm-mrad, while the amplitude of the 2 MHz oscillation is around 0.04 $$pi$$ mm-mrad. The results indicate that the high-frequency oscillation component occupying about ten-percent of the beam from the RF source travels a few meters passing through a magnetic lens focusing system.

Journal Articles

Alternation of magnetic anisotropy accompanied by metal-insulator transition in strained ultrathin manganite heterostructures

Kobayashi, Masaki*; Anh, L. D.*; Suzuki, Masahiro*; Kaneta-Takada, Shingo*; Takeda, Yukiharu; Fujimori, Shinichi; Shibata, Goro*; Tanaka, Arata*; Tanaka, Masaaki*; Oya, Shinobu*; et al.

Physical Review Applied (Internet), 15(6), p.064019_1 - 064019_10, 2021/06

 Times Cited Count:4 Percentile:27.71(Physics, Applied)

223 (Records 1-20 displayed on this page)