Shigeki, Okamura; Kitamura, Seiji; Takahashi, Kenji
Transactions of 18th International Conference on Structural Mechanics in Reactor Technology (SMiRT-18), 0 Pages, 2005/08
In Japan, several kinds of three-dimensional seismic isolation system for next-generation nuclear power plant such as fast reactors have been studied in recent years. We proposed a structural concept of a vertical component isolation system, assuming a building adopting a horizontal base isolation system. In this concept, a reactor vessel and major primary components are suspended from a large common deck supported by isolation devices consisting of large coned disk springs. In order to verify the isolation performance of the vertical component isolation system, 1/8 series of shaking table tests using a scale model were conducted. The test model was composed of 4 vertical isolation devices, common deck and horizontal load suspension system which supports the horizontal load by the earthquake. For the design earthquake, the system smoothly operated, and sufficient isolation characteristics were shown. The examination on the horizontal load suspension system was carried out. The simulation analysis results matched well the test results, so the validity of the design technique was able to be verified. As the result, the prospect that the vertical isolation system applied to the FBR plant could technically realize was obtained.
Kitamura, Seiji; Shigeki, Okamura; Kenji, Takahashi
Proceedings of 2005 ASME International Mechanical Engineering Congress and Exposition (CD-ROM), 0 Pages, 2004/07
Several kinds of three-dimensional seismic isolation system for next-generation nuclear power plant such as fast reactors have been studied in recent years. We proposed a structural concept of a vertical component isolation system, assuming a building adopting a horizontal base isolation system. In this concept, a reactor vessel and major primary components are suspended from a large common deck supported by isolation devices consisting of large coned disk springs. In order to verify the isolation performance of the vertical component isolation system, 1/8 series of shaking table tests using a scale model were conducted. The test model was composed of 4 vertical isolation devices, common deck and horizontal load suspension system. For the design earthquake, the system smoothly operated, and sufficient isolation characteristics were shown. The simulation analysis results matched well the test results, so the validity of the design technique was able to be verified. As the result, the prospect that the vertical isolation system applied to the FBR plant could technically realize was obtained.