論文

Silicon avalanche photodiode linear-array detector with multichannel scaling system for pulsed synchrotron X-ray experiments

岸本 俊二*; 三井 隆也; 春木 理恵*; 依田 芳卓*; 谷口 敬*; 島崎 昇一*; 池野 正弘*; 斉藤 正俊*; 田中 真伸*

Journal of Instrumentation (Internet), 10(5), p.C05030_1 - C05030_6, 2015/05

 被引用回数:6 パーセンタイル:28.31(Instruments & Instrumentation)

We developed an X-ray detector system using a 64-pixel silicon avalanche photodiode Si-APD linear array and fast pulse-counting electronics for multichannel scaling. The Si-APD linear array consists of 64 pixels each 0.01$$times$$0.02 cm$$^{2}$$ in size, with a pixel pitch of 0.015 cm and depletion depth of 0.001 cm. The fast electronics, consisting of an ultrafast application-specific integrated circuit and field-programmable gate arrays, can record both the position and timing of X-rays arriving at each pixel of the linear array with 1 ns pulse-pair resolution. The count distribution was measured using 14.4 keV synchrotron X-rays for nuclear resonant forward scattering experiments on $$^{57}$$Fe, and the spatial resolution was improved by inclining the detector. We also successfully measured amorphous alloy Fe$$_{78}$$Si$$_{9}$$B$$_{13}$$ during heating.

論文

Nuclear resonant scattering measurements on $$^{57}$$Fe by multichannel scaling with a 64 pixel silicon avalanche photodiode linear-array detector

岸本 俊二*; 三井 隆也; 春木 理恵*; 依田 芳卓*; 谷口 敬*; 島崎 昇一*; 池野 正弘*; 斉藤 正俊*; 田中 真伸*

Review of Scientific Instruments, 85(11), p.113102_1 - 113102_5, 2014/11

 被引用回数:8 パーセンタイル:36.77(Instruments & Instrumentation)

We developed a silicon avalanche photodiode (Si-APD) linear-array detector for use in nuclear resonant scattering experiments using synchrotron X-rays. The Si-APD linear array consists of 64 pixels (pixel size: 0,01$$times$$0.02 cm$$^{2}$$) with a pixel pitch of 0.015 cm and depletion depth of 0.001 cm. An ultrafast frontend circuit allows the X-ray detector to obtain a high output. High-performance integrated circuits achieve multichannel scaling over 1024 continuous time bins with a 1 ns resolution for each pixel without dead time. The multichannel scaling method enabled us to record a time spectrum of the 14.4 keV nuclear radiation at each pixel with a time resolution of 1.4 ns (FWHM). This method was successfully applied to nuclear forward scattering and nuclear small-angle scattering on $$^{57}$$Fe.

報告書

HTTR第2次燃料体組立,貯蔵作業における燃料取扱い

富本 浩; 加藤 康; 大和田 博之; 佐藤 直; 島崎 洋祐; 小澤 太教; 篠原 正憲; 濱本 真平; 栃尾 大輔; 野尻 直喜; et al.

JAEA-Technology 2009-025, 29 Pages, 2009/06

JAEA-Technology-2009-025.pdf:21.78MB

高温工学試験研究炉(HTTR)は、1989年に初装荷燃料を装荷し、初臨界を達成してから、10年が過ぎ、現在も初装荷燃料にて運転を継続中である。燃料体組立は12種類の濃縮度がある燃料棒4770本を黒鉛ブロックに装荷する。第2次燃料体組立では150体の燃料体を組立てた。燃料棒は設計上、燃料棒の濃縮度誤装荷防止について考慮されているが、さらに確実な取扱いができるように作業上の誤装荷対策をあらかじめ検討した。燃料棒の受入れを2008年6月から開始し、原子炉建家内で組立作業を行い、新燃料貯蔵ラックへの貯蔵を行った。組立,貯蔵作業は、3回の期間に分けて実施し、各々の期間ごとに使用前検査を受検し、2008年9月にすべての作業を完了した。その後、同年11月に使用前検査合格証を受けた。本報告は第2次燃料体の組立,貯蔵作業における燃料取扱いについてまとめたものである。