Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Tomita, Jumpei; Tomita, Ryohei; Suzuki, Daisuke; Yasuda, Kenichiro; Miyamoto, Yutaka
Journal of Nuclear Science and Technology, 63(4), p.443 - 454, 2026/04
Times Cited Count:0 Percentile:0.00(Nuclear Science & Technology)Tomita, Ryohei; Tomita, Jumpei; Yomogida, Takumi; Suzuki, Daisuke; Takamiya, Koichi*; Igarashi, Yasuhito*; Yamasaki, Shinya*; Sakaguchi, Aya*; Yasuda, Kenichiro
Analytical Methods, 12 Pages, 2026/00
Tomita, Ryohei; Tomita, Jumpei; Yomogida, Takumi; Suzuki, Daisuke; Miyamoto, Yutaka; Yasuda, Kenichiro
Analytical Methods, 17(44), p.9017 - 9025, 2025/10
Times Cited Count:1 Percentile:0.00(Chemistry, Analytical)Tomita, Ryohei; Tomita, Jumpei; Suzuki, Daisuke; Miyamoto, Yutaka; Yasuda, Kenichiro
Journal of Nuclear Science and Technology, 62(10), p.939 - 948, 2025/10
Times Cited Count:1 Percentile:46.18(Nuclear Science & Technology)A new automated particle measurement (APM) combined with micromanipulation using large geometry secondary ion mass spectrometry instrument was proposed and demonstrated to remove the particle mixing effect, which indicated that the aggregation of uranium particles was detected as a single uranium particle, from APM results. The results showed that the new APM method was more effective than the traditional APM method in removing the particle mixing effect from the APM results and determining the existence of minor uranium isotopes in the samples.
U/
U isotopic analysis of trace uranium in safeguards environmental samples using multicollector inductively coupled plasma mass spectrometryTomita, Jumpei; Tomita, Ryohei; Suzuki, Daisuke; Yasuda, Kenichiro; Miyamoto, Yutaka
Journal of the American Society for Mass Spectrometry, 35(6), p.1178 - 1183, 2024/05
Times Cited Count:1 Percentile:15.28(Biochemical Research Methods)A sensitive analytical technique was investigated in order to determine 10
order of
U/
U ratio in the sub-ng of uranium using a multi-collector ICP-MS. First, the solution volume was concentrated to one tenth to obtain higher intensities. Next, data acquisition was started from the beginning of the solution uptake and continued until all solution was exhausted. Taking advantage of multi-collector measurement, all data were used with excepting the portion affected by air mixing at the beginning and end of sample introduction. The isotope ratios were calculated from the total counts of each isotope. This technique was applied to U isotope standard (IRMM-184) to measure the 10
order of
U/
U ratio in the sub-ng of uranium. Measured values were in good agreement with the certified value within the uncertainity (
=2). The uncertainties obtained with this new technique (32% on average) were revised to be 10 times smaller than those obtained with the conventionalmethod.
Tomita, Ryohei; Tomita, Jumpei; Suzuki, Daisuke; Yasuda, Kenichiro; Miyamoto, Yutaka
Hosha Kagaku, (48), p.1 - 15, 2023/09
Secondary Ion Mass Spectrometry (SIMS) is the method to detect secondary ions produced by the sputtering of primary ions. SIMS is one of effective method to measure isotopic composition of particles containing nuclear material in environmental sample for safeguards. We are a group member of the International Atomic Energy Agency (IAEA)'s network of analytical laboratories and have developed analytical techniques using SIMS and other mass spectrometers for nuclear safeguards. We will introduce the principle of SIMS and analytical techniques developed by our group to measure isotopic composition of uranium particles which having a particle diameter of micron order in environmental sample for safeguards.
Yamashita, Takuya; Honda, Takeshi*; Mizokami, Masato*; Nozaki, Kenichiro*; Suzuki, Hiroyuki*; Pellegrini, M.*; Sakai, Takeshi*; Sato, Ikken; Mizokami, Shinya*
Nuclear Technology, 209(6), p.902 - 927, 2023/06
Times Cited Count:7 Percentile:66.64(Nuclear Science & Technology)Miyamoto, Yutaka; Suzuki, Daisuke; Tomita, Ryohei; Tomita, Jumpei; Yasuda, Kenichiro
Isotope News, (786), p.22 - 25, 2023/04
no abstracts in English
100 MeV/nucleonPohl, T.*; Sun, Y. L.*; Obertelli, A.*; Lee, J.*; G
mez-Ramos, M.*; Ogata, Kazuyuki*; Yoshida, Kazuki; Cai, B. S.*; Yuan, C. X.*; Brown, B. A.*; et al.
Physical Review Letters, 130(17), p.172501_1 - 172501_8, 2023/04
Times Cited Count:19 Percentile:86.92(Physics, Multidisciplinary)We report on the first proton-induced single proton- and neutron-removal reactions from the neutron deficient
O nucleus with large Fermi-surface asymmetry at
100 MeV/nucleon. Our results provide the first quantitative contributions of multiple reaction mechanisms including the quasifree knockout, inelastic scattering, and nucleon transfer processes. It is shown that the inelastic scattering and nucleon transfer, usually neglected at such energy regime, contribute about 50% and 30% to the loosely bound proton and deeply bound neutron removal, respectively.
Tomita, Ryohei; Tomita, Jumpei; Yomogida, Takumi; Suzuki, Daisuke; Yasuda, Kenichiro; Esaka, Fumitaka; Miyamoto, Yutaka
KEK Proceedings 2022-2, p.108 - 113, 2022/11
Automated Particle Measurement (APM) is the first measurement of environmental sample for safeguard purpose. APM tells us the number of particles in sample, their enrichment and their location. Precision and accuracy of APM is easily affected by particle condition. We have investigated how influential baking temperature in sample preparation are for uranium secondary ion quantity, uranium hydride generation and particle crystallinity. Our experimental results showed that baking temperature of 800
C reduced uranium secondary ion quantity to 33% compared with baking at 350
C. Uranium hydride generation ratio of the sample baked at 850
C was also 4 times higher than the sample baked at 350
C. Baking at 850
C raised only crystallinity of uranium particles. Baking sample at too high temperature caused less uranium secondary ion generation and much more uranium hydride generation. It made precision and accuracy of APM worse. In our experiment, baking at 350
C is suitable for uranium particles in the safeguards sample.
Tomita, Jumpei; Tomita, Ryohei; Suzuki, Daisuke; Yasuda, Kenichiro; Miyamoto, Yutaka
KEK Proceedings 2022-2, p.154 - 158, 2022/11
Precise determination of minor U isotopes (
U and
U) of particles from the safeguard environmental samples is powerful method for detecting the undeclared nuclear activities. In this study, preparation method of U particle was examined to utilize for the minor U isotope determination. The porous silica particles were used as the particle matrix and lutetium was mixed to the impregnation solution as U impregnation indicator for the particle picking. The result of the Scanning Electron Microscope indicated that the contacting the solution with Si particles overnight gently could produce the impregnated particles effectively rather than the mixing them with PFA stick.
Yamamoto, Kazami; Kinsho, Michikazu; Hayashi, Naoki; Saha, P. K.; Tamura, Fumihiko; Yamamoto, Masanobu; Tani, Norio; Takayanagi, Tomohiro; Kamiya, Junichiro; Shobuda, Yoshihiro; et al.
Journal of Nuclear Science and Technology, 59(9), p.1174 - 1205, 2022/09
Times Cited Count:10 Percentile:73.53(Nuclear Science & Technology)In the Japan Proton Accelerator Research Complex, the purpose of the 3 GeV rapid cycling synchrotron (RCS) is to accelerate a 1 MW, high-intensity proton beam. To achieve beam operation at a repetition rate of 25 Hz at high intensities, the RCS was elaborately designed. After starting the RCS operation, we carefully verified the validity of its design and made certain improvements to establish a reliable operation at higher power as possible. Consequently, we demonstrated beam operation at a high power, namely, 1 MW. We then summarized the design, actual performance, and improvements of the RCS to achieve a 1 MW beam.
Tomita, Ryohei; Tomita, Jumpei; Yomogida, Takumi; Suzuki, Daisuke; Yasuda, Kenichiro; Esaka, Fumitaka; Miyamoto, Yutaka
KEK Proceedings 2021-2, p.146 - 150, 2021/12
no abstracts in English
Suzuki, Daisuke; Tomita, Ryohei; Tomita, Jumpei; Esaka, Fumitaka; Yasuda, Kenichiro; Miyamoto, Yutaka
Journal of Radioanalytical and Nuclear Chemistry, 328(1), p.103 - 111, 2021/04
Times Cited Count:6 Percentile:45.56(Chemistry, Analytical)An analytical technique was developed to determine the age of uranium particles for safeguards. After the chemical separation of uranium and thorium, the
Th/
U ratio was measured using single-collector inductively coupled plasma mass spectrometry and a
U-based reference material comprising a certain amount of
Th as a progeny nuclide of
U. The results allowed us to determine the purification age of two certified materials, i.e., U-850 and U-100, which was in good agreement with the reference purification age (61 y). Moreover, the age of a single U-850 particle was determined with a difference of -28 to 2 years from the reference date.
Yamashita, Takuya; Sato, Ikken; Honda, Takeshi*; Nozaki, Kenichiro*; Suzuki, Hiroyuki*; Pellegrini, M.*; Sakai, Takeshi*; Mizokami, Shinya*
Nuclear Technology, 206(10), p.1517 - 1537, 2020/10
Times Cited Count:25 Percentile:89.33(Nuclear Science & Technology)Ishida, Tsuyoshi*; Fujito, Wataru*; Yamashita, Hiroto*; Naoi, Makoto*; Fujii, Hirokazu*; Suzuki, Kenichiro*; Matsui, Hiroya
Rock Mechanics and Rock Engineering, 52(2), p.543 - 553, 2019/02
Times Cited Count:19 Percentile:57.46(Engineering, Geological)We pressurized and injected water in a hole drilled downward from a floor of the 500 m level gallery in MIU, central Japan. Acoustic emissions (AEs) monitored with 16 sensors in four boreholes located 1 m away from the HF hole exhibited two-dimensional distributions, which likely delineate a crack induced by the fracturing. Expansions of the regions in which AEs occurred were observed only immediately after the first and second BDs. Many AE events in other periods were distributed within the regions where AE events had already occurred. The initial motion polarities of P-waves indicate that tensile-dominant AE events occurred when the regions expanded and they were distributed primarily on the frontiers of the regions where AE events had already occurred. The experimental results suggest that increasing the injection flow rate is effective for generating new cracks in the refracturing, with the new crack expansions being induced by tensile fracturing.
Ni from the (
,
) reactionElekes, Z.*; Kripk
,
*; Sohler, D.*; Sieja, K.*; Ogata, Kazuyuki*; Yoshida, Kazuki; Doornenbal, P.*; Obertelli, A.*; Authelet, G.*; Baba, Hidetada*; et al.
Physical Review C, 99(1), p.014312_1 - 014312_7, 2019/01
Times Cited Count:14 Percentile:71.36(Physics, Nuclear)The nuclear structure of the
Ni nucleus was investigated by (
,
) reaction using a NaI(Tl) array to detect the deexciting prompt
rays. A new transition with an energy of 2227 keV was identified by
and
coincidences. Our shell-model calculations using the Lenzi, Nowacki, Poves, and Sieja interaction produced good candidates for the experimental proton hole states in the observed energy region, and the theoretical cross sections showed good agreement with the experimental values. Although we could not assign all the experimental states to the theoretical ones unambiguously, the results are consistent with a reasonably large Z = 28 shell gap for nickel isotopes in accordance with previous studies.
Miyamoto, Yutaka; Yasuda, Kenichiro; Suzuki, Daisuke; Esaka, Fumitaka; Magara, Masaaki
KEK Proceedings 2017-6, p.292 - 298, 2017/11
Our updated analytical techniques of ultra-trace plutonium in the IAEA environmental samples by ICP-MS were mentioned. Some careful techniques to accurately determine ultra-trace plutonium in the range of femto-grams to pico-grams were introduced. The uncertainties of analytical results were estimated according to the GUM concept. Our trials of determination of sub-femto grams americium in an environmental sample were also mentioned.
Pu/
Pu in individual U-Pu mixed oxide particles by means of a combination of alpha spectrometry and ICP-MSEsaka, Fumitaka; Yasuda, Kenichiro; Suzuki, Daisuke; Miyamoto, Yutaka; Magara, Masaaki
Talanta, 165, p.122 - 127, 2017/04
Times Cited Count:100 Percentile:96.00(Chemistry, Analytical)The isotope ratios of
Pu/
Pu,
Pu/
Pu,
Pu/
Pu, and
Pu/
Pu were measured for individual Pu and U-Pu mixed oxide particles by a combination of alpha spectrometry and inductively coupled plasma mass spectrometry (ICP-MS). As a consequence, we were able to determine the
Pu/
Pu,
Pu/
Pu, and
Pu/
Pu isotope ratios with ICP-MS after particle dissolution and chemical separation of uranium, plutonium and americium with UTEVA resins. Furthermore,
Pu/
Pu isotope ratios were able to be calculated by using both the
Pu/(
Pu+
Pu) activity ratios that had been measured through alpha spectrometry and the
Pu/
Pu isotope ratios determined through ICP-MS. Therefore, the combined use of alpha spectrometry and ICP-MS is useful in determining plutonium isotope ratios, including
Pu/
Pu, in individual U-Pu mixed oxide particles.
O
(001) surface; A DFT studyMao, W.*; Chikada, Takumi*; Shimura, Kenichiro*; Suzuki, Akihiro*; Yamaguchi, Kenji; Terai, Takayuki*
Journal of Nuclear Materials, 443(1-3), p.555 - 561, 2013/11
Times Cited Count:4 Percentile:28.98(Materials Science, Multidisciplinary)In this work,
calculations based on density functional theory (DFT) and generalized gradient approximation were performed to investigate the structural and electronic properties of the cubic Er
O
(001) surface and H adsorption processes on this surface. Several stable adsorption sites were identified, and at the most energetically favorable adsorption sites it was found that H bonds with O atoms at the cubic Er
O
(001) surface with an adsorption energy of 295.68 kJ mol
at coverage 1/8 ML, which was inclined to decrease with the increase of H coverage (
1/4 ML). In addition, the calculations revealed that the dissociative H atom configurations have adsorption energies that are at least 152.64 kJ mol
greater than the H
molecule configurations on the surface. These results are discussed in regard of the hydrogen isotope permeation behavior in the tritium permeation barrier in a fusion reactor.