First switching network unit for the JT-60SA superconducting central solenoid

Lampasi, A.*; Zito, P.*; Coletti, A.*; Novello, L.*; 松川 誠; 島田 勝弘; Burini, F.*; Kuate-Fone, Y.*; Taddia, G.*; Tenconi, S.*

Fusion Engineering and Design, 98-99, p.1098 - 1102, 2015/10

 被引用回数:9 パーセンタイル:61(Nuclear Science & Technology)

In JT-60SA, the first SNU (prototype), consisting of six cubicles, was assembled in 2013. The factory tests on this system, including tests at full current and voltage, are being performed throughout 2014. The manufacturing of the remaining three SNUs will proceed after the success of such tests. The main characteristics of the developed SNU are; (1) Snchronized use of an electronic static circuit breaker (SCB) in parallel with an electromechanical bypass switch (BPS), (2) Nominal voltage of 5 kV, with a specific circuit to limit the transient voltage to 5.5 kV, (3) DC current interruption up to 20 kA, (4) Light BPS with opening and closing times shorter than 15 ms and 65 ms, respectively, (5) Breakdown resistance adaptable from 0.25 $$Omega$$ to 3.75 $$Omega$$ by four selectors, (7) Fully electronic making switch (MS) and (8) Breakdown resistors that could dissipate much more than 90 MJ.

論文

Design and implementation of four 20 kA, 5 kV hybrid switching networks for plasma ignition in the international tokamak JT-60SA

Burini, F.*; Kuate-Fone, Y.*; Taddia, G.*; Tenconi, S.*; Lampasi, A.*; Zito, P.*; 松川 誠; 島田 勝弘; Coletti, A.*; Novello, L.*

Proceedings of 40th Annual Conference of the IEEE Industrial Electronics Society (IECON 2014), p.5035 - 5040, 2014/10

This paper describes the design and implementation of the Switching Network Unit (SNU) for the superconducting Central Solenoid coils of the international nuclear fusion experiment JT-60SA to be built in Naka, Japan. The SNU can interrupt a current up to 20 kA in less than 1 ms to create a voltage up to 5 kV. It is realized with a hybrid switch integrating an electro-mechanical device and a solid state Static Circuit Breaker, parallel connected. SNU resistance can be pre-arranged and dynamically reduced by a solid state making switch. Preliminary test results confirmed the current balance of the multiple parallel branches constituting the solid state switch and proper behavior of the devices, confirming simulations results. Further applications could be medium voltage DC networks (either naval or land based); higher DC voltages are practicable.