Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 57

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

SUMRAY: R and Python codes for calculating cancer risk due to radiation exposure of a population

Sasaki, Michiya*; Furukawa, Kyoji*; Satoh, Daiki; Shimada, Kazumasa; Kudo, Shinichi*; Takagi, Shunji*; Takahara, Shogo; Kai, Michiaki*

Journal of Radiation Protection and Research, 48(2), p.90 - 99, 2023/06

This paper reports on the calculation code that is the result of the activities of the "Task Group for Development of Cancer Risk Estimation Codes Associated with Radiation Exposure (FY2020-2021)" established by the Japan Health Physics Society. In order to promote research on the estimation of cancer risk associated with radiation exposure, the Task Group decided to disclose the source code, including the algorithm and parameters used in the calculations, and to release the code under a license that permits modification and redistribution of the code. The computational code was named SUMRAY and coded in two computer languages, that is R and Python. The code is capable of calculating the accumulated excess risk using Monte Carlo methods with a 95% confidence interval. The results of SUMRAY were compared with the results of the existing codes whose source code is not publicly available, under the same calculation conditions. From the results, it was found that they were in reasonable agreement within the confidence interval. It is expected that SUMRAY, an open-source software, will be used as a common basis for cancer risk estimation studies associated with radiation exposure.

Journal Articles

The Japan Health Physics Society Guideline on Dose Monitoring for the Lens of the Eye

Yokoyama, Sumi*; Tsujimura, Norio; Hashimoto, Makoto; Yoshitomi, Hiroshi; Kato, Masahiro*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Sekiguchi, Hiroshi*; Koguchi, Yasuhiro*; Ono, Koji*; et al.

Journal of Radiation Protection and Research, 47(1), p.1 - 7, 2022/03

Background: In Japan, new regulations that revise the dose limit for the lens of the eye (the lens), operational quantities, and measurement positions for the lens dose were enforced in April 2021. Based on the international safety standards, national guidelines, the results of the Radiation Safety Research Promotion Fund of the Nuclear Regulatory Authority, and other studies, the Working Group of Radiation Protection Standardization Committee, the Japan Health Physics Society (JHPS) developed a guideline for radiation dose monitoring for the lens. Materials and Methods: The Working Group of the JHPS discussed the criteria of non-uniform exposure and the management criteria set to not exceed the dose limit for the lens. Results and Discussion: In July 2020, the JHPS guideline was published. The guideline consists of three parts: main text, explanations, and 26 questions. In the questions, the corresponding answers were prepared, and specific examples were provided to enable similar cases to be addressed. Conclusion: With the development of guideline on radiation dose monitoring of the lens, radiation managers and workers will be able to smoothly comply with revised regulations and optimise radiation protection.

Journal Articles

Development of guidelines on radiation protection for the lens of the eye in Japan

Yokoyama, Sumi*; Iwai, Satoshi*; Tsujimura, Norio; Hashimoto, Makoto; Yoshitomi, Hiroshi; Kato, Masahiro*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Sekiguchi, Hiroshi*; Koguchi, Yasuhiro*; et al.

Proceedings of 15th International Congress of the International Radiation Protection Association (IRPA-15) (Internet), 8 Pages, 2022/00

Journal Articles

Hydrogen absorption mechanism into iron in aqueous solution including metal cations by laser ablation tests and first-principles calculations

Igarashi, Takahiro; Otani, Kyohei; Kato, Chiaki; Sakairi, Masatoshi*; Togashi, Yusuke*; Baba, Kazuhiko*; Takagi, Shusaku*

ISIJ International, 61(4), p.1085 - 1090, 2021/04

 Times Cited Count:1 Percentile:8.06(Metallurgy & Metallurgical Engineering)

In order to clarify the effect of metal cations (Zn$$^{2+}$$, Mg$$^{2+}$$, Na$$^{+}$$) in aqueous solution on hydrogen permeation into iron, the amount of hydrogen permeation from iron surface was measured by electrochemical tests with a laser ablation. Moreover, in order to obtain the basic mechanism of hydrogen permeation with metal cation, first-principles calculations were used to acquire the adsorption potential of the metal cation and the electronic state around iron surface. By Zn$$^{2+}$$ in solution, anodic reaction on ablated surface by laser irradiation was suppressed. Also, by quantum analysis Zn atoms were chemically bonded stronger than Na and Mg atoms to iron surface. It was suggested that the dissolution reaction of iron was suppressed by the formation of the Zn layer, and that lead suppression of hydrogen permeation into iron.

Journal Articles

Thermally altered subsurface material of asteroid (162173) Ryugu

Kitazato, Kohei*; Milliken, R. E.*; Iwata, Takahiro*; Abe, Masanao*; Otake, Makiko*; Matsuura, Shuji*; Takagi, Yasuhiko*; Nakamura, Tomoki*; Hiroi, Takahiro*; Matsuoka, Moe*; et al.

Nature Astronomy (Internet), 5(3), p.246 - 250, 2021/03

 Times Cited Count:43 Percentile:96.93(Astronomy & Astrophysics)

Here we report observations of Ryugu's subsurface material by the Near-Infrared Spectrometer (NIRS3) on the Hayabusa2 spacecraft. Reflectance spectra of excavated material exhibit a hydroxyl (OH) absorption feature that is slightly stronger and peak-shifted compared with that observed for the surface, indicating that space weathering and/or radiative heating have caused subtle spectral changes in the uppermost surface. However, the strength and shape of the OH feature still suggests that the subsurface material experienced heating above 300 $$^{circ}$$C, similar to the surface. In contrast, thermophysical modeling indicates that radiative heating does not increase the temperature above 200 $$^{circ}$$C at the estimated excavation depth of 1 m, even if the semimajor axis is reduced to 0.344 au. This supports the hypothesis that primary thermal alteration occurred due to radiogenic and/or impact heating on Ryugu's parent body.

Journal Articles

The Surface composition of asteroid 162173 Ryugu from Hayabusa2 near-infrared spectroscopy

Kitazato, Kohei*; Milliken, R. E.*; Iwata, Takahiro*; Abe, Masanao*; Otake, Makiko*; Matsuura, Shuji*; Arai, Takehiko*; Nakauchi, Yusuke*; Nakamura, Tomoki*; Matsuoka, Moe*; et al.

Science, 364(6437), p.272 - 275, 2019/04

 Times Cited Count:259 Percentile:99.73(Multidisciplinary Sciences)

The near-Earth asteroid 162173 Ryugu, the target of Hayabusa2 sample return mission, is believed to be a primitive carbonaceous object. The Near Infrared Spectrometer (NIRS3) on Hayabusa2 acquired reflectance spectra of Ryugu's surface to provide direct measurements of the surface composition and geological context for the returned samples. A weak, narrow absorption feature centered at 2.72 micron was detected across the entire observed surface, indicating that hydroxyl (OH)-bearing minerals are ubiquitous there. The intensity of the OH feature and low albedo are similar to thermally- and/or shock-metamorphosed carbonaceous chondrite meteorites. There are few variations in the OH-band position, consistent with Ryugu being a compositionally homogeneous rubble-pile object generated from impact fragments of an undifferentiated aqueously altered parent body.

Journal Articles

NIRS3; The Near Infrared Spectrometer on Hayabusa2

Iwata, Takahiro*; Kitazato, Kohei*; Abe, Masanao*; Otake, Makiko*; Arai, Takehiko*; Arai, Tomoko*; Hirata, Naru*; Hiroi, Takahiro*; Honda, Chikatoshi*; Imae, Naoya*; et al.

Space Science Reviews, 208(1-4), p.317 - 337, 2017/07

 Times Cited Count:54 Percentile:71.62(Astronomy & Astrophysics)

NIRS3: The Near Infrared Spectrometer is installed on the Hayabusa2 spacecraft to observe the target C-type asteroid 162173 Ryugu at near infrared wavelengths of 1.8 to 3.2 micrometer. It aims to obtain reflectance spectra in order to detect absorption bands of hydrated and hydroxide minerals in the 3 micrometer-band. We adopted a linear-image sensor with indium arsenide (InAs) photo diodes and a cooling system with a passive radiator to achieve an optics temperature of 188 K, which enables to retaining sufficient sensitivity and noise level in the 3 micrometer wavelength region. We conducted ground performance tests for the NIRS3 flight model (FM) to confirm its baseline specifications. The results imply that the properties such as the signal-to-noise ratio (SNR) conform to scientific requirements to determine the degree of aqueous alteration, such as CM or CI chondrite, and the stage of thermal metamorphism on the asteroid surface.

Journal Articles

Operation status of the J-PARC ion source

Oguri, Hidetomo; Okoshi, Kiyonori; Ikegami, Kiyoshi*; Yamazaki, Saishun; Takagi, Akira*; Koizumi, Isao; Ueno, Akira

JPS Conference Proceedings (Internet), 8, p.011009_1 - 011009_6, 2015/09

Journal Articles

Comparison between Monte Carlo simulation and measurement with a 3D polymer gel dosimeter for dose distributions in biological samples

Furuta, Takuya; Maeyama, Takuya*; Ishikawa, Kenichi*; Fukunishi, Nobuhisa*; Fukasaku, Kazuaki*; Takagi, Shu*; Noda, Shigeho*; Himeno, Ryutaro*; Hayashi, Shinichiro*

Physics in Medicine & Biology, 60(16), p.6531 - 6546, 2015/08

 Times Cited Count:18 Percentile:62.62(Engineering, Biomedical)

Low reproducibility of dose distribution in inhomogeneous regions such as soft matter near bones is known with the simple dose analysis currently adopted in treatment planning of particle cancer therapy. Therefore a treatment planning system based on Monte Carlo simulation having better accuracy is highly desired. In order to assess the simulation accuracy of a Monte Carlo simulation code in situations closely related to medical application, we performed a comparison of dose distribution in a biological sample obtained by experiment and that by simulation. In particular, we irradiate a carbon beam on a biological sample composed of fresh chicken meat and bones, with a PAGAT gel dosimeter placed behind it, and compare the complex dose distribution in the gel dosimeter created by the beam passing through the inhomogeneous sample. Monte Carlo simulation using PHITS code was conducted by reconstructing the biological sample from its computed tomography images. The simulation accurately reproduced the experimental distal edge structure of the dose distribution with an accuracy under about 2 mm.

Journal Articles

Engineering a spin-orbital magnetic insulator by tailoring superlattices

Matsuno, Jobu*; Ihara, Kota*; Yamamura, Shugen*; Wadachi, Hiroki*; Ishii, Kenji; Shankar, V.*; Kee, H.-Y.*; Takagi, Hidenori*

Physical Review Letters, 114(24), p.247209_1 - 247209_5, 2015/06

 Times Cited Count:148 Percentile:97.75(Physics, Multidisciplinary)

Journal Articles

Parallel computing with Particle and Heavy Ion Transport code System (PHITS)

Furuta, Takuya; Sato, Tatsuhiko; Ogawa, Tatsuhiko; Niita, Koji*; Ishikawa, Kenichi*; Noda, Shigeho*; Takagi, Shu*; Maeyama, Takuya*; Fukunishi, Nobuhisa*; Fukasaku, Kazuaki*; et al.

Proceedings of Joint International Conference on Mathematics and Computation, Supercomputing in Nuclear Applications and the Monte Carlo Method (M&C + SNA + MC 2015) (CD-ROM), 9 Pages, 2015/04

In Particle and Heavy Ion Transport code System PHITS, two parallel computing functions are prepared to reduce the computational time. One is the distributed-memory parallelization using message passing interface (MPI) and the other is the shared-memory parallelization using OpenMP directives. Each function has advantages and disadvantages, and thus, by adopting both functions in PHITS, it is possible to conduct parallel computing suited for needs of users. It is also possible to conduct the hybrid parallelization by the intra-node OpenMP parallelization and the inter-node MPI parallelization in supercomputer systems. Each parallelization functions were explained together with some application results obtained using a workstation and a supercomputer system, K computer at RIKEN.

Journal Articles

Radiological characteristics of MRI-based VIP polymer gel under carbon beam irradiation

Maeyama, Takuya*; Fukunishi, Nobuhisa*; Ishikawa, Kenichi*; Furuta, Takuya; Fukasaku, Kazuaki*; Takagi, Shu*; Noda, Shigeho*; Himeno, Ryutaro*; Fukuda, Shigekazu*

Radiation Physics and Chemistry, 107, p.7 - 11, 2015/02

 Times Cited Count:12 Percentile:70.51(Chemistry, Physical)

We study the radiological characteristics of VIP polymer gel dosimeters under carbon beam irradiation with energy of 135 and 290 AMeV. To evaluate dose response of VIP polymer gels, the transverse relaxation rate R2 of the dosimeters measured by magnetic resonance imaging (MRI) as a function of linear energy transfer (LET), rather than penetration depth, as is usually done in previous reports. LET is evaluated by use of the particle transport simulation code PHITS. Our results reveal that the dose response decreases with increasing dose-averaged LET and that the response-LET relation also varies with incident carbon beam energy. The latter can be explained by taking into account the contribution from fragmentation products. Furthermore, as an application of the evaluated response-LET relation, we compare the measured and simulated R2 distribution in a VIP gel formed by heterogeneous irradiation and obtain agreement in overall distribution and range within an accuracy of 5% and 1-2 mm, respectively.

Journal Articles

Beam test of a new radio frequency quadrupole linac for the Japan Proton Accelerator Research Complex

Kondo, Yasuhiro; Morishita, Takatoshi; Yamazaki, Saishun; Hori, Toshihiko; Sawabe, Yuki; Chishiro, Etsuji; Fukuda, Shimpei; Hasegawa, Kazuo; Hirano, Koichiro; Kikuzawa, Nobuhiro; et al.

Physical Review Special Topics; Accelerators and Beams, 17(12), p.120101_1 - 120101_8, 2014/12

 Times Cited Count:6 Percentile:42.9(Physics, Nuclear)

We performed a beam test of a new radio frequency quadrupole linac (RFQ III) for the beam current upgrade of the Japan Proton Accelerator Research Complex. First, the conditioning of RFQ III was conducted, and after 20 h of conditioning, RFQ III became very stable with a nominal peak power and duty factor of 400 kW and 1.5%, respectively. An off-line beam test was subsequently conducted before installation in the accelerator tunnel. The transmission, transverse emittance, and energy spread of the 50-mA negative hydrogen beam from RFQ III were measured and compared with simulation results. The experiment and simulation results showed good agreement; therefore, we conclude that the performance of RFQ III conforms to its design.

Journal Articles

Beam test of a new RFQ for the J-PARC linac

Kondo, Yasuhiro; Morishita, Takatoshi; Yamazaki, Saishun; Hori, Toshihiko; Sawabe, Yuki; Takagi, Akira*

Proceedings of 27th International Linear Accelerator Conference (LINAC 2014) (Internet), p.267 - 269, 2014/12

We performed a beam test of a new 324-MHz 3-MeV H$$^{-}$$ RFQ (RFQ III) for the beam-current upgrade of the J-PARC linac. RFQ III is the first RFQ developed to meet the requirement of the J-PARC linac. The peak beam current is 50 mA, pulse length is 500 micro-sec, and the repetition is 25 Hz. Prior to the installation to the accelerator tunnel in summer of 2014, we constructed a test stand for off line testing of the new ion source and RFQ. Basic performances of RFQ III such as transmission and emittances were measured. In this paper, the beam test results are presented.

Journal Articles

Present status of J-PARC linac

Oguri, Hidetomo; Hasegawa, Kazuo; Ito, Takashi; Chishiro, Etsuji; Hirano, Koichiro; Morishita, Takatoshi; Shinozaki, Shinichi; Ao, Hiroyuki; Okoshi, Kiyonori; Kondo, Yasuhiro; et al.

Proceedings of 11th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.389 - 393, 2014/10

no abstracts in English

Journal Articles

Operation status of the J-PARC ion source

Okoshi, Kiyonori; Ikegami, Kiyoshi*; Koizumi, Isao; Ueno, Akira; Takagi, Akira*; Yamazaki, Saishun; Oguri, Hidetomo

Proceedings of 10th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.946 - 949, 2014/06

A J-PARC ion source driven with a LaB6 filament is being operated without any serious trouble since the restoration from the earthquake. The H$$^{-}$$ ion current from the source is routinely restricted 19 mA for the filament lifetime. In order to increase the beam power at the linac beam operation, the beam current from the ion source was increased to 22 mA. At this operation, the filament lifetime was estimated by the reduction in the filament current. According to the steep reduction in the filament current, the break of the filament was predicted. Although the filament has broken after 10 h from the steep current reduction, the beam operation was restarted 8 h later by the preparation for the exchange of new filament. At the study time for the 3 GeV synchrotron, the ion source was operated at 30 mA for 8 days.

Journal Articles

Development of a Cs-ceeded Rf-driven H$$^{-}$$ ion source for the J-PARC

Koizumi, Isao; Ueno, Akira; Okoshi, Kiyonori; Ikegami, Kiyoshi*; Takagi, Akira*; Yamazaki, Saishun; Oguri, Hidetomo

Proceedings of 10th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.920 - 923, 2014/06

In order to satisfy the J-PARC (Japan Proton Accelerator Research Complex) 2nd stage requirements the J-PARC rf-driven H$$^{-}$$ ion source is under development. The source plasma is produced by an about 50 W CW 30 MHz-rf and an about 40 kW pulsed 2 MHz-rf. The Cs is installed into the plasma chamber by opening the Cs-valve between the plasma chamber and the Cs oven, which is heated to 200$$sim$$240 $$^{circ}$$C. The H$$^{-}$$ ion beam current is maximized by optimizing the Cs quantity depending upon the Cs-valve opening time, the PE temperature depending upon the flow rate of the air through the PE cooling plate, the AMFC by the AMFC coil current, and so on. The experimental results using the plasma chamber made of copper, which satisfied the above requirements, were reported last year. The experimental results using the plasma chamber made of stainless steel are presented in this paper. The observed several interesting differences between the two plasma chambers are also presented.

Journal Articles

Dependence of beam emittance on plasma electrode temperature and rf-power, and filter-field tuning with center-gapped rod-filter magnets in J-PARC rf-driven H$$^{-}$$ ion source

Ueno, Akira; Koizumi, Isao; Okoshi, Kiyonori; Ikegami, Kiyoshi*; Takagi, Akira*; Yamazaki, Saishun; Oguri, Hidetomo

Review of Scientific Instruments, 85(2), p.02B133_1 - 02B133_5, 2014/02

 Times Cited Count:6 Percentile:29.22(Instruments & Instrumentation)

no abstracts in English

Journal Articles

Verification and validation procedures of calculation codes for determining corrosive conditions in the BWR primary cooling system based on water radiolysis and mixed potential models

Uchida, Shunsuke*; Wada, Yoichi*; Yamamoto, Seiji*; Takagi, Junichi*; Hisamune, Kenji*

Journal of Nuclear Science and Technology, 51(1), p.24 - 36, 2014/01

 Times Cited Count:9 Percentile:57.19(Nuclear Science & Technology)

ECP in the BWR primary cooling system can be measured only in the restricted region. In order to determine ECP at any location, ECP should be evaluated by computer simulation codes consisting of water radiolysis models to determine the concentrations of corrosive radiolytic species and mixed potential models to determine ECP based on corrosive species. Mitigation of SCC crack growth rate due to decreasing ECP can be authorized by the JSME Standards, while mitigation of ECP due to hydrogen addition has not been authorized yet. In the paper, standard procedures to authorize the computer simulation codes based on the verification and validation method are proposed. The numerical justification of every code applied as a standard code should be verified and its accuracy and applicability for plant analysis should be validated. Benchmark problems for verification processes are proposed and comparison of the calculated results with the measured ones for the plant of evaluation is required.

Journal Articles

Coordinated Research Projects (CRP) on atomic and molecular data at IAEA, 3; Data evaluation of code comparison activities

Ichikawa, Yukikazu*; Takagi, Shuichi*; Nakamura, Yoshiharu*; Imai, Makoto*; Sasaki, Akira

Purazuma, Kaku Yugo Gakkai-Shi, 89(9), p.600 - 610, 2013/09

no abstracts in English

57 (Records 1-20 displayed on this page)