Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 160

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

The Development and application of the stirred-reactor coupon analysis (SRCA) test method

Reiser, J. T.*; Neeway, J. J.*; Cooley, S. K.*; Parruzot, B.*; Heredia-Langner, A.*; Gin, S.*; Thomas, M.*; Smith, N. J.*; Icenhower, J. P.*; Stone-Weiss, N.*; et al.

International Journal of Applied Glass Science, 16(4), p.e16707_1 - e16707_16, 2025/10

 Times Cited Count:0 Percentile:0.00(Materials Science, Ceramics)

Journal Articles

Development of an electron spin resonance spectroscopy code for measuring carbonate radicals in tooth enamel and verification of its practicality using irradiated Japanese macaque teeth

Yamashita, Takuma*; Hayashi, Teppei*; Mitsuyasu, Yusuke*; Ono, Kenta*; Iwami, Satone*; Kino, Yasushi*; Sekine, Tsutomu*; Oka, Toshitaka; Takahashi, Atsushi*; Shimizu, Yoshinaka*; et al.

International Journal of Radiation Biology, 8 Pages, 2025/00

 Times Cited Count:1 Percentile:76.46(Biology)

no abstracts in English

Journal Articles

Optimization of microwave power in ESR dosimetry of tooth enamel in Japanese macaques

Hayashi, Teppei*; Yamashita, Takuma*; Mitsuyasu, Yusuke*; Ono, Kenta*; Iwami, Satone*; Kino, Yasushi*; Sekine, Tsutomu*; Oka, Toshitaka; Takahashi, Atsushi*; Shimizu, Yoshinaka*; et al.

International Journal of Radiation Biology, 8 Pages, 2025/00

 Times Cited Count:0 Percentile:0.00

no abstracts in English

Journal Articles

Study on microwave power dependency of electron spin resonance spectrum of carbonate radicals in teeth

Iwami, Satone*; Yamashita, Takuma*; Mitsuyasu, Yusuke*; Ono, Kenta*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

KEK Proceedings 2024-6, p.91 - 95, 2024/12

We aim to improve the detection limit of the ESR dosimetry method. In this study, the saturation behavior of each radical was investigated by varying the microwave power during ESR measurement. Based on the difference in spin relaxation time between carbonate radicals and native radicals, it is expected that the signal-to-noise ratio improves and the detection limit can be lowered when the microwave power is increased to 4.0 mW.

Journal Articles

Improved multicomponent analysis method for electron spin resonance spectra of gamma-irradiated tooth enamel

Yamashita, Takuma*; Iwami, Satone*; Mitsuyasu, Yusuke*; Ono, Kenta*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

KEK Proceedings 2024-6, p.85 - 90, 2024/12

To clarify the radiation effects of the accident at the TEPCO's Fukushima Daiichi NPP on living organisms, it is important to accurately estimate the dose to each individual. We have developed a multi-component analysis program using random number optimization to extract only the components derived from carbonate radicals from the ESR spectra.

Journal Articles

Molecular geochemistry of radium; A key to understanding cation adsorption reaction on clay minerals

Yamaguchi, Akiko; Kurihara, Yuichi*; Nagata, Kojiro*; Tanaka, Kazuya; Higaki, Shogo*; Kobayashi, Toru; Tanida, Hajime; Ohara, Yoshiyuki*; Yokoyama, Keiichi; Yaita, Tsuyoshi; et al.

Journal of Colloid and Interface Science, 661, p.317 - 332, 2024/05

 Times Cited Count:9 Percentile:73.83(Chemistry, Physical)

no abstracts in English

Journal Articles

Estimation of external dose for wild Japanese macaques captured in Fukushima prefecture; Decomposition of electron spin resonance spectrum

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.

Radiation Protection Dosimetry, 199(14), p.1620 - 1625, 2023/09

 Times Cited Count:2 Percentile:35.31(Environmental Sciences)

We have been conducting dose assessments for Japanese macaques captured in Fukushima to reveal radiobiological effects on the low-dose expose animals. To accurately determine the external exposure dose, it is desirable to examine the analysis of the CO$$_{2}^{-}$$ radical intensity. We examined ESR spectra of teeth of 10 macaques captured in Fukushima by two spectrum-decomposition algorithms.

Journal Articles

A Study on accuracy of analysis of the radiation-induced component in the ESR spectra of teeth

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.

KEK Proceedings 2022-2, p.120 - 125, 2022/11

We investigate the effect of sample's anisotropy and measurement condition to obtain the higher reproducibility for the shape of the ESR spectrum and the intensity of CO$$_{2}^{-}$$ radical.

Journal Articles

Extended X-ray absorption fine structure spectroscopy measurements and ${it ab initio}$ molecular dynamics simulations reveal the hydration structure of the radium(II) ion

Yamaguchi, Akiko; Nagata, Kojiro*; Kobayashi, Keita; Tanaka, Kazuya; Kobayashi, Toru; Tanida, Hajime; Shimojo, Kojiro; Sekiguchi, Tetsuhiro; Kaneta, Yui; Matsuda, Shohei; et al.

iScience (Internet), 25(8), p.104763_1 - 104763_12, 2022/08

 Times Cited Count:19 Percentile:67.28(Multidisciplinary Sciences)

no abstracts in English

Journal Articles

Detection limit of electron spin resonance for Japanese deciduous tooth enamel and density separation method for enamel-dentine separation

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; Osaka, Ken*; Sasaki, Keiichi*; et al.

Journal of Radiation Research (Internet), 63(4), p.609 - 614, 2022/07

AA2021-0724.pdf:0.68MB

 Times Cited Count:5 Percentile:45.57(Biology)

Electron spin resonance (ESR) dosimetry is one of the most powerful tools for radiation dose reconstruction. The detection limit of this technique using human teeth is reported to be 56 mGy or 67 mGy; however, the absorbed dose of Fukushima residents after the Fukushima Daiichi Nuclear Power Plant (FNPP) accident was estimated to be lower than this detection limit. Our aim is to assess the absorbed radiation dose of children in Fukushima Prefecture after the accident; therefore, it is important to estimate the detection limit for their teeth. The detection limit for enamel of deciduous teeth of Japanese children separated by the mechanical method is estimated to be 115.0 mGy. The density separation method can effectively separate enamel from third molars of Japanese people. As we have collected thousands of teeth from children in Fukushima, the present technique may be useful to examine their external absorbed dose after the FNPP accident.

Journal Articles

Investigation of hydration and adsorption structures on clay minerals of radium by EXAFS

Yamaguchi, Akiko; Nagata, Kojiro*; Tanaka, Kazuya; Kobayashi, Keita; Kobayashi, Toru; Shimojo, Kojiro; Tanida, Hajime; Sekiguchi, Tetsuhiro; Kaneta, Yui; Matsuda, Shohei; et al.

Hosha Kagaku, (45), p.28 - 30, 2022/03

no abstracts in English

Journal Articles

Development of dose estimation method using wild animal teeth for low dose exposure

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

KEK Proceedings 2021-2, p.91 - 96, 2021/12

We examined whether the ESR dose estimation method could be applied to wild Japanese macaque. In this work, we investigated the enamel preparation protocol and the analytical method of the ESR spectra.

Journal Articles

Rapid analysis of $$^{90}$$Sr in cattle bone and tooth samples by inductively coupled plasma mass spectrometry

Koarai, Kazuma; Matsueda, Makoto; Aoki, Jo; Yanagisawa, Kayo*; Terashima, Motoki; Fujiwara, Kenso; Kino, Yasushi*; Oka, Toshitaka; Takahashi, Atsushi*; Suzuki, Toshihiko*; et al.

Journal of Analytical Atomic Spectrometry, 36(8), p.1678 - 1682, 2021/08

 Times Cited Count:7 Percentile:49.48(Chemistry, Analytical)

Rapid analysis of $$^{90}$$Sr in bone and tooth samples of cattle were achieved by an inductively coupled plasma mass spectrometry (ICP-MS) coupled with mass shift and solid phase extraction techniques. Limit of detection (LOD) in the ICP-MS measurement of 0.1 g samples was lower than that of the radioactivity measurement. Analytical time of the ICP-MS method was reduced from 20 days to 11 hours, compared with the radiometric method. Therefore, the ICP-MS method can be rapid and useful procedure of $$^{90}$$Sr in small bone and tooth samples derived from terrestrial animals.

Journal Articles

Radioactivity and radionuclides in deciduous teeth formed before the Fukushima-Daiichi Nuclear Power Plant accident

Takahashi, Atsushi*; Chiba, Mirei*; Tanahara, Akira*; Aida, Jun*; Shimizu, Yoshinaka*; Suzuki, Toshihiko*; Murakami, Shinobu*; Koarai, Kazuma; Ono, Takumi*; Oka, Toshitaka; et al.

Scientific Reports (Internet), 11(1), p.10355_1 - 10355_11, 2021/05

 Times Cited Count:11 Percentile:48.31(Multidisciplinary Sciences)

Journal Articles

Thermally altered subsurface material of asteroid (162173) Ryugu

Kitazato, Kohei*; Milliken, R. E.*; Iwata, Takahiro*; Abe, Masanao*; Otake, Makiko*; Matsuura, Shuji*; Takagi, Yasuhiko*; Nakamura, Tomoki*; Hiroi, Takahiro*; Matsuoka, Moe*; et al.

Nature Astronomy (Internet), 5(3), p.246 - 250, 2021/03

 Times Cited Count:60 Percentile:95.33(Astronomy & Astrophysics)

Here we report observations of Ryugu's subsurface material by the Near-Infrared Spectrometer (NIRS3) on the Hayabusa2 spacecraft. Reflectance spectra of excavated material exhibit a hydroxyl (OH) absorption feature that is slightly stronger and peak-shifted compared with that observed for the surface, indicating that space weathering and/or radiative heating have caused subtle spectral changes in the uppermost surface. However, the strength and shape of the OH feature still suggests that the subsurface material experienced heating above 300 $$^{circ}$$C, similar to the surface. In contrast, thermophysical modeling indicates that radiative heating does not increase the temperature above 200 $$^{circ}$$C at the estimated excavation depth of 1 m, even if the semimajor axis is reduced to 0.344 au. This supports the hypothesis that primary thermal alteration occurred due to radiogenic and/or impact heating on Ryugu's parent body.

Journal Articles

External exposure dose estimation by electron spin resonance technique for wild Japanese macaque captured in Fukushima Prefecture

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; Osaka, Ken*; et al.

Radiation Measurements, 134, p.106315_1 - 106315_4, 2020/06

 Times Cited Count:10 Percentile:65.41(Nuclear Science & Technology)

The relationship between the CO$$_{2}$$ radical intensity and the absorbed dose (dose response curve) of tooth enamel of Japanese macaque was observed by electron spin resonance and the detection limit of our system was estimated to be 33.5 mGy, which is comparable to the detection limit for human molar teeth. Using the dose response curve, external exposure dose for seven wild Japanese macaques captured in Fukushima prefecture were examined. The results suggest that the external exposure dose for the wild Japanese macaques were ranged between 45 mGy to 300 mGy.

Journal Articles

$$omega N$$ scattering length from $$omega$$ photoproduction on the proton near the reaction threshold

Ishikawa, Takatsugu*; Fujimura, Hisako*; Fukasawa, Hiroshi*; Hashimoto, Ryo*; He, Q.*; Honda, Yuki*; Hosaka, Atsushi; Iwata, Takahiro*; Kaida, Shun*; Kasagi, Jirota*; et al.

Physical Review C, 101(5), p.052201_1 - 052201_6, 2020/05

 Times Cited Count:4 Percentile:41.23(Physics, Nuclear)

JAEA Reports

XAFS measurement of simulated waste glass samples (Joint research)

Nagai, Takayuki; Sasage, Kenichi; Okamoto, Yoshihiro; Shiwaku, Hideaki; Yamagishi, Hirona*; Ota, Toshiaki*; Inose, Takehiko*; Sato, Seiichi*; Hatakeyama, Kiyoshi*; Takahashi, Tomoe*; et al.

JAEA-Research 2019-003, 94 Pages, 2019/09

JAEA-Research-2019-003.pdf:7.92MB

The local structures of glass-forming elements and waste elements would change by the chemical composition of waste glass including those elements. In this study, simulated waste glass samples were prepared from borosilicate glass frit including phosphorus (P) or vanadium (V), and we investigated local structures of boron, sodium, and waste elements in these P glass and V glass samples by using synchrotron XAFS measurements in soft and hard X ray region.

Journal Articles

Cryogenic sample environments shared at the MLF, J-PARC

Kawamura, Seiko; Takahashi, Ryuta*; Ishikado, Motoyuki*; Yamauchi, Yasuhiro*; Nakamura, Masatoshi*; Ouchi, Keiichi*; Kira, Hiroshi*; Kambara, Wataru*; Aoyama, Kazuhiro*; Sakaguchi, Yoshifumi*; et al.

Journal of Neutron Research, 21(1-2), p.17 - 22, 2019/05

The Cryogenics and Magnets group in the Sample Environment team is responsible for operation of cryostats and magnets for user's experiments at the MLF in J-PARC. We have introduced a top-loading $$^4$$He cryostat, a bottom-loading $$^3$$He cryostat, a dilution refrigerator insert and a superconducting magnet. The frequency of use of them dramatically becomes higher in these two years, as the beam power and the number of proposal increase. To respond such situation, we have made efforts to enhance performance of these equipment as follows. The $$^3$$He cryostat originally involves an operation software for automatic initial cooling down to the base temperature and automatic re-charge of $$^3$$He. Recently we made an additional program for automatic temperature control with only the sorb heater. Last year, a new outer vacuum chamber of the magnet with an oscillating radial collimator (ORC) was fabricated. The data quality was drastically improved by introducing this ORC so that the magnet can be used even for the inelastic neutron scattering experiments.

JAEA Reports

Investigation of simulated waste glass samples prepared from borosilicate glass frit including vanadium

Nagai, Takayuki; Okamoto, Yoshihiro; Shiwaku, Hideaki; Inose, Takehiko*; Sato, Seiichi*; Hatakeyama, Kiyoshi*; Hirono, Kazuya*; Homma, Masanobu*; Kobayashi, Hiromi*; Takahashi, Tomoe*; et al.

JAEA-Research 2018-007, 87 Pages, 2018/11

JAEA-Research-2018-007.pdf:61.21MB

To select the chemical composition of a glass frit which can increase the waste content, the simulated waste glass samples prepared from a borosilicate glass frit including vanadium (V) were investigated by using Laser Ablation (LA) ICP-AES analysis, Raman spectrometry, and synchrotron XAFS measurement in this study on foundation business of the Agency for Natural Resources and Energy.

160 (Records 1-20 displayed on this page)